Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom

Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufa...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodríguez, Cristian F., Guzmán-Sastoque, Paula, Gantiva-Diaz, Mónica, Gómez, Saúl C., Quezada, Valentina, Muñoz-Camargo, Carolina, Osma, Johann F., Reyes, Luis H., Cruz, Juan C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689937/
https://www.ncbi.nlm.nih.gov/pubmed/38045919
http://dx.doi.org/10.1016/j.ohx.2023.e00493
_version_ 1785152455707721728
author Rodríguez, Cristian F.
Guzmán-Sastoque, Paula
Gantiva-Diaz, Mónica
Gómez, Saúl C.
Quezada, Valentina
Muñoz-Camargo, Carolina
Osma, Johann F.
Reyes, Luis H.
Cruz, Juan C.
author_facet Rodríguez, Cristian F.
Guzmán-Sastoque, Paula
Gantiva-Diaz, Mónica
Gómez, Saúl C.
Quezada, Valentina
Muñoz-Camargo, Carolina
Osma, Johann F.
Reyes, Luis H.
Cruz, Juan C.
author_sort Rodríguez, Cristian F.
collection PubMed
description Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufacturing processes. A cost-effective, passive microfluidic separator is presented, capable of efficiently sorting and purifying particles spanning the size range of 15 µm to 40 µm. Fabricated from Polymethyl Methacrylate (PMMA) substrates using laser ablation, this device circumvents the need for cleanroom facilities. Prior to fabrication, rigorous optimization of the device's design was carried out through computational simulations conducted in COMSOL Multiphysics. To gauge its performance, chitosan microparticles were employed as a test case. The results were notably promising, achieving a precision of 96.14 %. This quantitative metric underscores the device's precision and effectiveness in size-based particle separation. This low-cost and accessible microfluidic separator offers a pragmatic solution for laboratories and researchers seeking precise control over particle sizes, without the constraints of expensive manufacturing environments. This innovation not only mitigates the limitations tied to traditional cleanroom-based fabrication but also widens the horizons for various applications within the realms of chemistry and biology.
format Online
Article
Text
id pubmed-10689937
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106899372023-12-02 Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom Rodríguez, Cristian F. Guzmán-Sastoque, Paula Gantiva-Diaz, Mónica Gómez, Saúl C. Quezada, Valentina Muñoz-Camargo, Carolina Osma, Johann F. Reyes, Luis H. Cruz, Juan C. HardwareX Article Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufacturing processes. A cost-effective, passive microfluidic separator is presented, capable of efficiently sorting and purifying particles spanning the size range of 15 µm to 40 µm. Fabricated from Polymethyl Methacrylate (PMMA) substrates using laser ablation, this device circumvents the need for cleanroom facilities. Prior to fabrication, rigorous optimization of the device's design was carried out through computational simulations conducted in COMSOL Multiphysics. To gauge its performance, chitosan microparticles were employed as a test case. The results were notably promising, achieving a precision of 96.14 %. This quantitative metric underscores the device's precision and effectiveness in size-based particle separation. This low-cost and accessible microfluidic separator offers a pragmatic solution for laboratories and researchers seeking precise control over particle sizes, without the constraints of expensive manufacturing environments. This innovation not only mitigates the limitations tied to traditional cleanroom-based fabrication but also widens the horizons for various applications within the realms of chemistry and biology. Elsevier 2023-11-11 /pmc/articles/PMC10689937/ /pubmed/38045919 http://dx.doi.org/10.1016/j.ohx.2023.e00493 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rodríguez, Cristian F.
Guzmán-Sastoque, Paula
Gantiva-Diaz, Mónica
Gómez, Saúl C.
Quezada, Valentina
Muñoz-Camargo, Carolina
Osma, Johann F.
Reyes, Luis H.
Cruz, Juan C.
Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title_full Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title_fullStr Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title_full_unstemmed Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title_short Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
title_sort low-cost inertial microfluidic device for microparticle separation: a laser-ablated pmma lab-on-a-chip approach without a cleanroom
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689937/
https://www.ncbi.nlm.nih.gov/pubmed/38045919
http://dx.doi.org/10.1016/j.ohx.2023.e00493
work_keys_str_mv AT rodriguezcristianf lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT guzmansastoquepaula lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT gantivadiazmonica lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT gomezsaulc lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT quezadavalentina lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT munozcamargocarolina lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT osmajohannf lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT reyesluish lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom
AT cruzjuanc lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom