Cargando…
Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom
Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufa...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689937/ https://www.ncbi.nlm.nih.gov/pubmed/38045919 http://dx.doi.org/10.1016/j.ohx.2023.e00493 |
_version_ | 1785152455707721728 |
---|---|
author | Rodríguez, Cristian F. Guzmán-Sastoque, Paula Gantiva-Diaz, Mónica Gómez, Saúl C. Quezada, Valentina Muñoz-Camargo, Carolina Osma, Johann F. Reyes, Luis H. Cruz, Juan C. |
author_facet | Rodríguez, Cristian F. Guzmán-Sastoque, Paula Gantiva-Diaz, Mónica Gómez, Saúl C. Quezada, Valentina Muñoz-Camargo, Carolina Osma, Johann F. Reyes, Luis H. Cruz, Juan C. |
author_sort | Rodríguez, Cristian F. |
collection | PubMed |
description | Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufacturing processes. A cost-effective, passive microfluidic separator is presented, capable of efficiently sorting and purifying particles spanning the size range of 15 µm to 40 µm. Fabricated from Polymethyl Methacrylate (PMMA) substrates using laser ablation, this device circumvents the need for cleanroom facilities. Prior to fabrication, rigorous optimization of the device's design was carried out through computational simulations conducted in COMSOL Multiphysics. To gauge its performance, chitosan microparticles were employed as a test case. The results were notably promising, achieving a precision of 96.14 %. This quantitative metric underscores the device's precision and effectiveness in size-based particle separation. This low-cost and accessible microfluidic separator offers a pragmatic solution for laboratories and researchers seeking precise control over particle sizes, without the constraints of expensive manufacturing environments. This innovation not only mitigates the limitations tied to traditional cleanroom-based fabrication but also widens the horizons for various applications within the realms of chemistry and biology. |
format | Online Article Text |
id | pubmed-10689937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-106899372023-12-02 Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom Rodríguez, Cristian F. Guzmán-Sastoque, Paula Gantiva-Diaz, Mónica Gómez, Saúl C. Quezada, Valentina Muñoz-Camargo, Carolina Osma, Johann F. Reyes, Luis H. Cruz, Juan C. HardwareX Article Although microparticles are frequently used in chemistry and biology, their effectiveness largely depends on the homogeneity of their particle size distribution. Microfluidic devices to separate and purify particles based on their size have been developed, but many require expensive cleanroom manufacturing processes. A cost-effective, passive microfluidic separator is presented, capable of efficiently sorting and purifying particles spanning the size range of 15 µm to 40 µm. Fabricated from Polymethyl Methacrylate (PMMA) substrates using laser ablation, this device circumvents the need for cleanroom facilities. Prior to fabrication, rigorous optimization of the device's design was carried out through computational simulations conducted in COMSOL Multiphysics. To gauge its performance, chitosan microparticles were employed as a test case. The results were notably promising, achieving a precision of 96.14 %. This quantitative metric underscores the device's precision and effectiveness in size-based particle separation. This low-cost and accessible microfluidic separator offers a pragmatic solution for laboratories and researchers seeking precise control over particle sizes, without the constraints of expensive manufacturing environments. This innovation not only mitigates the limitations tied to traditional cleanroom-based fabrication but also widens the horizons for various applications within the realms of chemistry and biology. Elsevier 2023-11-11 /pmc/articles/PMC10689937/ /pubmed/38045919 http://dx.doi.org/10.1016/j.ohx.2023.e00493 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rodríguez, Cristian F. Guzmán-Sastoque, Paula Gantiva-Diaz, Mónica Gómez, Saúl C. Quezada, Valentina Muñoz-Camargo, Carolina Osma, Johann F. Reyes, Luis H. Cruz, Juan C. Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title | Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title_full | Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title_fullStr | Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title_full_unstemmed | Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title_short | Low-cost inertial microfluidic device for microparticle separation: A laser-Ablated PMMA lab-on-a-chip approach without a cleanroom |
title_sort | low-cost inertial microfluidic device for microparticle separation: a laser-ablated pmma lab-on-a-chip approach without a cleanroom |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10689937/ https://www.ncbi.nlm.nih.gov/pubmed/38045919 http://dx.doi.org/10.1016/j.ohx.2023.e00493 |
work_keys_str_mv | AT rodriguezcristianf lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT guzmansastoquepaula lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT gantivadiazmonica lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT gomezsaulc lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT quezadavalentina lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT munozcamargocarolina lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT osmajohannf lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT reyesluish lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom AT cruzjuanc lowcostinertialmicrofluidicdeviceformicroparticleseparationalaserablatedpmmalabonachipapproachwithoutacleanroom |