Cargando…
A fully interpretable machine learning model for increasing the effectiveness of urine screening
OBJECTIVES: This article addresses the need for effective screening methods to identify negative urine samples before urine culture, reducing the workload, cost, and release time of results in the microbiology laboratory. We try to overcome the limitations of current solutions, which are either too...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691191/ https://www.ncbi.nlm.nih.gov/pubmed/37658807 http://dx.doi.org/10.1093/ajcp/aqad099 |
_version_ | 1785152692033683456 |
---|---|
author | Del Ben, Fabio Da Col, Giacomo Cobârzan, Doriana Turetta, Matteo Rubin, Daniela Buttazzi, Patrizio Antico, Antonio |
author_facet | Del Ben, Fabio Da Col, Giacomo Cobârzan, Doriana Turetta, Matteo Rubin, Daniela Buttazzi, Patrizio Antico, Antonio |
author_sort | Del Ben, Fabio |
collection | PubMed |
description | OBJECTIVES: This article addresses the need for effective screening methods to identify negative urine samples before urine culture, reducing the workload, cost, and release time of results in the microbiology laboratory. We try to overcome the limitations of current solutions, which are either too simple, limiting effectiveness (1 or 2 parameters), or too complex, limiting interpretation, trust, and real-world implementation (“black box” machine learning models). METHODS: The study analyzed 15,312 samples from 10,534 patients with clinical features and the Sysmex Uf-1000i automated analyzer data. Decision tree (DT) models with or without lookahead strategy were used, as they offer a transparent set of logical rules that can be easily understood by medical professionals and implemented into automated analyzers. RESULTS: The best model achieved a sensitivity of 94.5% and classified negative samples based on age, bacteria, mucus, and 2 scattering parameters. The model reduced the workload by an additional 16% compared to the current procedure in the laboratory, with an estimated financial impact of €40,000/y considering 15,000 samples/y. Identified logical rules have a scientific rationale matched to existing knowledge in the literature. CONCLUSIONS: Overall, this study provides an effective and interpretable screening method for urine culture in microbiology laboratories, using data from the Sysmex UF-1000i automated analyzer. Unlike other machine learning models, our model is interpretable, generating trust and enabling real-world implementation. |
format | Online Article Text |
id | pubmed-10691191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-106911912023-12-02 A fully interpretable machine learning model for increasing the effectiveness of urine screening Del Ben, Fabio Da Col, Giacomo Cobârzan, Doriana Turetta, Matteo Rubin, Daniela Buttazzi, Patrizio Antico, Antonio Am J Clin Pathol Original Articles OBJECTIVES: This article addresses the need for effective screening methods to identify negative urine samples before urine culture, reducing the workload, cost, and release time of results in the microbiology laboratory. We try to overcome the limitations of current solutions, which are either too simple, limiting effectiveness (1 or 2 parameters), or too complex, limiting interpretation, trust, and real-world implementation (“black box” machine learning models). METHODS: The study analyzed 15,312 samples from 10,534 patients with clinical features and the Sysmex Uf-1000i automated analyzer data. Decision tree (DT) models with or without lookahead strategy were used, as they offer a transparent set of logical rules that can be easily understood by medical professionals and implemented into automated analyzers. RESULTS: The best model achieved a sensitivity of 94.5% and classified negative samples based on age, bacteria, mucus, and 2 scattering parameters. The model reduced the workload by an additional 16% compared to the current procedure in the laboratory, with an estimated financial impact of €40,000/y considering 15,000 samples/y. Identified logical rules have a scientific rationale matched to existing knowledge in the literature. CONCLUSIONS: Overall, this study provides an effective and interpretable screening method for urine culture in microbiology laboratories, using data from the Sysmex UF-1000i automated analyzer. Unlike other machine learning models, our model is interpretable, generating trust and enabling real-world implementation. Oxford University Press 2023-09-02 /pmc/articles/PMC10691191/ /pubmed/37658807 http://dx.doi.org/10.1093/ajcp/aqad099 Text en © American Society for Clinical Pathology, 2023. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Articles Del Ben, Fabio Da Col, Giacomo Cobârzan, Doriana Turetta, Matteo Rubin, Daniela Buttazzi, Patrizio Antico, Antonio A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title | A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title_full | A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title_fullStr | A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title_full_unstemmed | A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title_short | A fully interpretable machine learning model for increasing the effectiveness of urine screening |
title_sort | fully interpretable machine learning model for increasing the effectiveness of urine screening |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691191/ https://www.ncbi.nlm.nih.gov/pubmed/37658807 http://dx.doi.org/10.1093/ajcp/aqad099 |
work_keys_str_mv | AT delbenfabio afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT dacolgiacomo afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT cobarzandoriana afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT turettamatteo afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT rubindaniela afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT buttazzipatrizio afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT anticoantonio afullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT delbenfabio fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT dacolgiacomo fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT cobarzandoriana fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT turettamatteo fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT rubindaniela fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT buttazzipatrizio fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening AT anticoantonio fullyinterpretablemachinelearningmodelforincreasingtheeffectivenessofurinescreening |