Cargando…

Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study

AIM: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON (®) with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. MATERIALS AND METHODS: A prospective observational study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Pedgaonkar, Raj A., Singh, Naveen G., Dhananjaya, Manasa, Nagaraja, PS, Nagesh, KS, Prabhakar, V
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691584/
https://www.ncbi.nlm.nih.gov/pubmed/37861570
http://dx.doi.org/10.4103/aca.aca_9_23
_version_ 1785152764681125888
author Pedgaonkar, Raj A.
Singh, Naveen G.
Dhananjaya, Manasa
Nagaraja, PS
Nagesh, KS
Prabhakar, V
author_facet Pedgaonkar, Raj A.
Singh, Naveen G.
Dhananjaya, Manasa
Nagaraja, PS
Nagesh, KS
Prabhakar, V
author_sort Pedgaonkar, Raj A.
collection PubMed
description AIM: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON (®) with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. MATERIALS AND METHODS: A prospective observational study was conducted in 25 pediatric patients with age < 10 years who underwent elective cardiac surgery. DATA ANALYSIS: BlandAltman plot was constructed for interchangeability and Polar plot was constructed to know trending ability. RESULTS: A total of 250 datasets were analyzed. Spearman’s correlation coefficient for CO between ICON (®) and TTE showed good positive correlation (r = 0.850, 95% confidence interval 0.81 to 0.881, P <.0001). Moderate positive correlation was observed between ICON (®) and TTE for CI (r = 0.60, 95% confidence interval 0.515 to 0.674, P <.0001). Linear regression equations for CO and CI between ICON (®) and TTE were: y = 0.5230 + 0.8078 X (R(2) = 0.6597, P <.001) and y = 1.8350 + 0.5869 X (R(2) = 0.3985, P <.001) [y- ICON (®); X - TTE], respectively. BlandAltman plot for CO between ICON (®) and TTE showed a bias of 0.3012 with limits of agreement (LOA) being -0.69 to 1.3 and for CI bias was 0.6939 with LOA-2.1 to 3.5. Polar plot analysis showed an angular bias of 8.1750, with radial LOA being −13.74° to 30.08° for CO and angular bias of 6.6931, with radial LOA being −15.69° to 29.07° for CI. CONCLUSION: ICON (®) monitor-derived parameters are not interchangeable with the values derived from TTE. However, the ICON (®) monitor demonstrated a good trending ability for both CO and CI.
format Online
Article
Text
id pubmed-10691584
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-106915842023-12-02 Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study Pedgaonkar, Raj A. Singh, Naveen G. Dhananjaya, Manasa Nagaraja, PS Nagesh, KS Prabhakar, V Ann Card Anaesth Original Article AIM: The present study was conducted to validate cardiac output (CO) and cardiac index (CI) obtained from electrical cardiometry (EC) ICON (®) with transthoracic echocardiography (TTE) in postoperative pediatric cardiac surgical patients. MATERIALS AND METHODS: A prospective observational study was conducted in 25 pediatric patients with age < 10 years who underwent elective cardiac surgery. DATA ANALYSIS: BlandAltman plot was constructed for interchangeability and Polar plot was constructed to know trending ability. RESULTS: A total of 250 datasets were analyzed. Spearman’s correlation coefficient for CO between ICON (®) and TTE showed good positive correlation (r = 0.850, 95% confidence interval 0.81 to 0.881, P <.0001). Moderate positive correlation was observed between ICON (®) and TTE for CI (r = 0.60, 95% confidence interval 0.515 to 0.674, P <.0001). Linear regression equations for CO and CI between ICON (®) and TTE were: y = 0.5230 + 0.8078 X (R(2) = 0.6597, P <.001) and y = 1.8350 + 0.5869 X (R(2) = 0.3985, P <.001) [y- ICON (®); X - TTE], respectively. BlandAltman plot for CO between ICON (®) and TTE showed a bias of 0.3012 with limits of agreement (LOA) being -0.69 to 1.3 and for CI bias was 0.6939 with LOA-2.1 to 3.5. Polar plot analysis showed an angular bias of 8.1750, with radial LOA being −13.74° to 30.08° for CO and angular bias of 6.6931, with radial LOA being −15.69° to 29.07° for CI. CONCLUSION: ICON (®) monitor-derived parameters are not interchangeable with the values derived from TTE. However, the ICON (®) monitor demonstrated a good trending ability for both CO and CI. Wolters Kluwer - Medknow 2023 2023-10-13 /pmc/articles/PMC10691584/ /pubmed/37861570 http://dx.doi.org/10.4103/aca.aca_9_23 Text en Copyright: © 2023 Annals of Cardiac Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Pedgaonkar, Raj A.
Singh, Naveen G.
Dhananjaya, Manasa
Nagaraja, PS
Nagesh, KS
Prabhakar, V
Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title_full Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title_fullStr Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title_full_unstemmed Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title_short Comparison of Noninvasive Cardiac Output Monitoring by Electrical Cardiometry with Transthoracic Echocardiography in Postoperative Paediatric Cardiac Surgical Patients - A Prospective Observational Study
title_sort comparison of noninvasive cardiac output monitoring by electrical cardiometry with transthoracic echocardiography in postoperative paediatric cardiac surgical patients - a prospective observational study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691584/
https://www.ncbi.nlm.nih.gov/pubmed/37861570
http://dx.doi.org/10.4103/aca.aca_9_23
work_keys_str_mv AT pedgaonkarraja comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT singhnaveeng comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT dhananjayamanasa comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT nagarajaps comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT nageshks comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy
AT prabhakarv comparisonofnoninvasivecardiacoutputmonitoringbyelectricalcardiometrywithtransthoracicechocardiographyinpostoperativepaediatriccardiacsurgicalpatientsaprospectiveobservationalstudy