Cargando…

Sensitivity and specificity of secondary dose calculation for head and neck treatment plans

PURPOSE: Secondary dose calculation (SDC) with an independent algorithm is one option to perform plan‐specific quality assurance (QA). While measurement‐based QA can potentially detect errors in plan delivery, the dose values are typically only compared to calculations on homogeneous phantom geometr...

Descripción completa

Detalles Bibliográficos
Autores principales: Wegener, Sonja, Abu Rashed, Ruaa, Sauer, Otto A., Razinskas, Gary
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691627/
https://www.ncbi.nlm.nih.gov/pubmed/37690124
http://dx.doi.org/10.1002/acm2.14139
_version_ 1785152773754454016
author Wegener, Sonja
Abu Rashed, Ruaa
Sauer, Otto A.
Razinskas, Gary
author_facet Wegener, Sonja
Abu Rashed, Ruaa
Sauer, Otto A.
Razinskas, Gary
author_sort Wegener, Sonja
collection PubMed
description PURPOSE: Secondary dose calculation (SDC) with an independent algorithm is one option to perform plan‐specific quality assurance (QA). While measurement‐based QA can potentially detect errors in plan delivery, the dose values are typically only compared to calculations on homogeneous phantom geometries instead of patient CT data. We analyzed the sensitivity and specificity of an SDC software by purposely introducing different errors and determined thresholds for optimal decisions. METHODS: Thirty head and neck VMAT plans and 30 modifications of those plans, including errors related to density and beam modelling, were recalculated using RadCalc with a Monte Carlo algorithm. Decision thresholds were obtained by receiver operating characteristics (ROC) analysis. For comparison, measurement‐based QA using the ArcCHECK phantom was carried out and evaluated in the same way. RESULTS: Despite optimized decision thresholds, none of the systems was able to reliably detect all errors. ArcCHECK analysis using a 2%/2 mm criterion with a threshold of 91.1% had an area under the curve (AUC) of 0.80. Evaluating differences in recalculated and planned DVH parameter of the target structures in RadCalc with a 2% threshold an AUC of 0.86 was achieved. Out‐of‐field deviations could be attributed to weaknesses in the beam model. CONCLUSIONS: Secondary dose calculation with RadCalc is an alternative to established measurement‐based phantom QA. Different tools catch different errors; therefore, a combination of approaches should be preferred.
format Online
Article
Text
id pubmed-10691627
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-106916272023-12-02 Sensitivity and specificity of secondary dose calculation for head and neck treatment plans Wegener, Sonja Abu Rashed, Ruaa Sauer, Otto A. Razinskas, Gary J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Secondary dose calculation (SDC) with an independent algorithm is one option to perform plan‐specific quality assurance (QA). While measurement‐based QA can potentially detect errors in plan delivery, the dose values are typically only compared to calculations on homogeneous phantom geometries instead of patient CT data. We analyzed the sensitivity and specificity of an SDC software by purposely introducing different errors and determined thresholds for optimal decisions. METHODS: Thirty head and neck VMAT plans and 30 modifications of those plans, including errors related to density and beam modelling, were recalculated using RadCalc with a Monte Carlo algorithm. Decision thresholds were obtained by receiver operating characteristics (ROC) analysis. For comparison, measurement‐based QA using the ArcCHECK phantom was carried out and evaluated in the same way. RESULTS: Despite optimized decision thresholds, none of the systems was able to reliably detect all errors. ArcCHECK analysis using a 2%/2 mm criterion with a threshold of 91.1% had an area under the curve (AUC) of 0.80. Evaluating differences in recalculated and planned DVH parameter of the target structures in RadCalc with a 2% threshold an AUC of 0.86 was achieved. Out‐of‐field deviations could be attributed to weaknesses in the beam model. CONCLUSIONS: Secondary dose calculation with RadCalc is an alternative to established measurement‐based phantom QA. Different tools catch different errors; therefore, a combination of approaches should be preferred. John Wiley and Sons Inc. 2023-09-10 /pmc/articles/PMC10691627/ /pubmed/37690124 http://dx.doi.org/10.1002/acm2.14139 Text en © 2023 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Wegener, Sonja
Abu Rashed, Ruaa
Sauer, Otto A.
Razinskas, Gary
Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title_full Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title_fullStr Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title_full_unstemmed Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title_short Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
title_sort sensitivity and specificity of secondary dose calculation for head and neck treatment plans
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691627/
https://www.ncbi.nlm.nih.gov/pubmed/37690124
http://dx.doi.org/10.1002/acm2.14139
work_keys_str_mv AT wegenersonja sensitivityandspecificityofsecondarydosecalculationforheadandnecktreatmentplans
AT aburashedruaa sensitivityandspecificityofsecondarydosecalculationforheadandnecktreatmentplans
AT sauerottoa sensitivityandspecificityofsecondarydosecalculationforheadandnecktreatmentplans
AT razinskasgary sensitivityandspecificityofsecondarydosecalculationforheadandnecktreatmentplans