Cargando…

Applying the reference values of real-ear-to-coupler-difference for deaf and hard-of-hearing children in Taiwan: Cautions and considerations

Measurement of real-ear-to-coupler differentials (RECDs) is a critical part of the hearing aid (HA) verification process. This study examines the validity of reference RECD values preset by the HA analyzer, Audioscan RM500, for deaf-and-hard-of-hearing (DHH) children in Taiwan. RECD measurements wer...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Chun-Yi, Chang, Yi-ping, Ma, Ying-Chuan Julie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10691684/
https://www.ncbi.nlm.nih.gov/pubmed/38039315
http://dx.doi.org/10.1371/journal.pone.0295236
Descripción
Sumario:Measurement of real-ear-to-coupler differentials (RECDs) is a critical part of the hearing aid (HA) verification process. This study examines the validity of reference RECD values preset by the HA analyzer, Audioscan RM500, for deaf-and-hard-of-hearing (DHH) children in Taiwan. RECD measurements were performed on 658 ears of DHH children. A linear mixed model was used to analyze the reference and measured RECD values. The findings revealed slight disparities between normative RECD values from North America and those observed in Taiwanese DHH children. While generally small (less than 5 dB), these differences imply potential challenges in achieving optimal HA fitting in specific scenarios. Therefore, we recommend individualized RECD/REM measurements for cases of poor auditory performance, certain frequency ranges, or notable variations in ear canal volume. From a clinical perspective, while broadly applicable, the use of North American RECD normative data in Taiwan requires cautious consideration of potential minor variations. This study contributes to current knowledge by affirming the use of a Western RECD database for Taiwanese DHH children. However, we underscore the ongoing importance of individualized HA fitting strategies, particularly for cases with stagnant intervention progress. While built-in RECD reference values can offer preliminary fitting guidance, especially in busy clinical settings, our study sheds light on the circumstances where caution is essential. Audiologists can efficiently allocate their time and effort by focusing on personalized RECD measurements for cases exhibiting suboptimal intervention outcomes, thereby effectively optimizing HA gain settings.