Cargando…
VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform
BACKGROUND: VersaCross is a novel radiofrequency transseptal solution that may improve the efficiency and workflow of transseptal puncture (TSP). The aim of this study was to compare the VersaCross transseptal system with mechanical needle systems during mitral transcatheter edge-to-edge repair (M-T...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692349/ https://www.ncbi.nlm.nih.gov/pubmed/38046864 http://dx.doi.org/10.1016/j.shj.2023.100203 |
_version_ | 1785152923345354752 |
---|---|
author | Doshi, Sagar N. Savvoulidis, Panagiotis Mechery, Anthony Lawton, Ewa Nadir, M. Adnan |
author_facet | Doshi, Sagar N. Savvoulidis, Panagiotis Mechery, Anthony Lawton, Ewa Nadir, M. Adnan |
author_sort | Doshi, Sagar N. |
collection | PubMed |
description | BACKGROUND: VersaCross is a novel radiofrequency transseptal solution that may improve the efficiency and workflow of transseptal puncture (TSP). The aim of this study was to compare the VersaCross transseptal system with mechanical needle systems during mitral transcatheter edge-to-edge repair (M-TEER) with the PASCAL device. METHODS: This is a single-center retrospective study of consecutive patients who underwent M-TEER with the PASCAL. Transseptal puncture was undertaken with either a mechanical needle or the VersaCross wire. The primary endpoints were success of TSP and successful delivery of the Edwards sheath on the chosen delivery wire. Secondary endpoints included number of wires used, tamponade rate, interval from femoral venous access to TSP and first PASCAL device deployment, procedural death, and stroke. RESULTS: Thirty-three consecutive patients (10 with mechanical needle, 23 with VersaCross) who underwent M-TEER with the Edwards PASCAL device were identified. All patients had successful TSP. In the mechanical needle group, the Edwards sheath was successfully delivered on the Superstiff Amplatz wire in all cases. In the VersaCross arm, the radiofrequency wire was used successfully for delivery of the sheath in all cases. There were no cases of pericardial effusion/tamponade in either arm. Interval from femoral venous access to TSP and to deployment of the first PASCAL device was shorter with the VersaCross system. Significantly fewer wires were used with VersaCross. There were no procedural deaths or strokes in either group. CONCLUSIONS: VersaCross appears a safe and effective method of TSP and for delivery of the 22Fr sheath for M-TEER with PASCAL. |
format | Online Article Text |
id | pubmed-10692349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-106923492023-12-03 VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform Doshi, Sagar N. Savvoulidis, Panagiotis Mechery, Anthony Lawton, Ewa Nadir, M. Adnan Struct Heart Original Research BACKGROUND: VersaCross is a novel radiofrequency transseptal solution that may improve the efficiency and workflow of transseptal puncture (TSP). The aim of this study was to compare the VersaCross transseptal system with mechanical needle systems during mitral transcatheter edge-to-edge repair (M-TEER) with the PASCAL device. METHODS: This is a single-center retrospective study of consecutive patients who underwent M-TEER with the PASCAL. Transseptal puncture was undertaken with either a mechanical needle or the VersaCross wire. The primary endpoints were success of TSP and successful delivery of the Edwards sheath on the chosen delivery wire. Secondary endpoints included number of wires used, tamponade rate, interval from femoral venous access to TSP and first PASCAL device deployment, procedural death, and stroke. RESULTS: Thirty-three consecutive patients (10 with mechanical needle, 23 with VersaCross) who underwent M-TEER with the Edwards PASCAL device were identified. All patients had successful TSP. In the mechanical needle group, the Edwards sheath was successfully delivered on the Superstiff Amplatz wire in all cases. In the VersaCross arm, the radiofrequency wire was used successfully for delivery of the sheath in all cases. There were no cases of pericardial effusion/tamponade in either arm. Interval from femoral venous access to TSP and to deployment of the first PASCAL device was shorter with the VersaCross system. Significantly fewer wires were used with VersaCross. There were no procedural deaths or strokes in either group. CONCLUSIONS: VersaCross appears a safe and effective method of TSP and for delivery of the 22Fr sheath for M-TEER with PASCAL. Elsevier 2023-06-22 /pmc/articles/PMC10692349/ /pubmed/38046864 http://dx.doi.org/10.1016/j.shj.2023.100203 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Doshi, Sagar N. Savvoulidis, Panagiotis Mechery, Anthony Lawton, Ewa Nadir, M. Adnan VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title | VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title_full | VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title_fullStr | VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title_full_unstemmed | VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title_short | VersaCross Transseptal System for Mitral Transcatheter Edge-To-Edge Repair With the PASCAL Repair Platform |
title_sort | versacross transseptal system for mitral transcatheter edge-to-edge repair with the pascal repair platform |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692349/ https://www.ncbi.nlm.nih.gov/pubmed/38046864 http://dx.doi.org/10.1016/j.shj.2023.100203 |
work_keys_str_mv | AT doshisagarn versacrosstransseptalsystemformitraltranscatheteredgetoedgerepairwiththepascalrepairplatform AT savvoulidispanagiotis versacrosstransseptalsystemformitraltranscatheteredgetoedgerepairwiththepascalrepairplatform AT mecheryanthony versacrosstransseptalsystemformitraltranscatheteredgetoedgerepairwiththepascalrepairplatform AT lawtonewa versacrosstransseptalsystemformitraltranscatheteredgetoedgerepairwiththepascalrepairplatform AT nadirmadnan versacrosstransseptalsystemformitraltranscatheteredgetoedgerepairwiththepascalrepairplatform |