Cargando…

Interference by piperacillin/tazobactam in the measurement of creatinine with the Jaffe method and of total protein with the biuret method

Serum creatinine and total protein are routinely measured biochemical parameters used in clinical medicine. An abnormal result caused by interference with the assay does not accurately reflect a patient's clinical state and therefore risks misleading clinicians. We report the case of a patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Dimeski, Goce, Kruger, Peter S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692513/
https://www.ncbi.nlm.nih.gov/pubmed/38045524
http://dx.doi.org/10.51893/2021.2.cr1
Descripción
Sumario:Serum creatinine and total protein are routinely measured biochemical parameters used in clinical medicine. An abnormal result caused by interference with the assay does not accurately reflect a patient's clinical state and therefore risks misleading clinicians. We report the case of a patient who had unexplainable high creatinine and total protein results. The blood collection was contaminated with intravenous fluid and the patient was receiving piperacillin/tazobactam. Additional laboratory studies demonstrated piperacillin/tazobactam was the cause of the false positive results and the elevation in both serum creatinine and protein level was dependent on the concentration of antibiotic present.