Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study

Objective: The accuracy of different non-invasive body temperature measurement methods in intensive care unit (ICU) patients is uncertain. We aimed to study the accuracy of three commonly used methods. Design: Prospective observational study. Setting: ICUs of two tertiary Australian hospitals. Parti...

Descripción completa

Detalles Bibliográficos
Autores principales: Cutuli, Salvatore L., Osawa, Eduardo A., Eyeington, Christopher T., Proimos, Helena, Canet, Emmanuel, Young, Helen, Peck, Leah, Eastwood, Glenn M., Glassford, Neil J., Bailey, Michael, Bellomo, Rinaldo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692569/
https://www.ncbi.nlm.nih.gov/pubmed/38046071
http://dx.doi.org/10.51893/2021.3.OA12
_version_ 1785152971303026688
author Cutuli, Salvatore L.
Osawa, Eduardo A.
Eyeington, Christopher T.
Proimos, Helena
Canet, Emmanuel
Young, Helen
Peck, Leah
Eastwood, Glenn M.
Glassford, Neil J.
Bailey, Michael
Bellomo, Rinaldo
author_facet Cutuli, Salvatore L.
Osawa, Eduardo A.
Eyeington, Christopher T.
Proimos, Helena
Canet, Emmanuel
Young, Helen
Peck, Leah
Eastwood, Glenn M.
Glassford, Neil J.
Bailey, Michael
Bellomo, Rinaldo
author_sort Cutuli, Salvatore L.
collection PubMed
description Objective: The accuracy of different non-invasive body temperature measurement methods in intensive care unit (ICU) patients is uncertain. We aimed to study the accuracy of three commonly used methods. Design: Prospective observational study. Setting: ICUs of two tertiary Australian hospitals. Participants: Critically ill patients admitted to the ICU. Interventions: Invasive (intravascular and intra-urinary bladder catheter) and non-invasive (axillary chemical dot, tympanic infrared, and temporal scanner) body temperature measurements were taken at study inclusion and every 4 hours for the following 72 hours. Main outcome measures: Accuracy of non-invasive body temperature measurement methods was assessed by the Bland–Altman approach, accounting for repeated measurements and significant explanatory variables that were identified by regression analysis. Clinical adequacy was set at limits of agreement (LoA) of 1°C compared with core temperature. Results: We studied 50 consecutive critically ill patients who were mainly admitted to the ICU after cardiac surgery. From over 375 observations, invasive core temperature (mostly pulmonary artery catheter) ranged from 33.9°C to 39°C. On average, the LoA between invasive and non-invasive measurements methods were about 3°C. The temporal scanner showed the worst performance in estimating core temperature (bias, 0.66°C; LoA, –1.23°C, +2.55°C), followed by tympanic infrared (bias, 0.44°C; LoA, –1.73°C, +2.61°C) and axillary chemical dot methods (bias, 0.32°C; LoA, –1.64°C, +2.28°C). No methods achieved clinical adequacy even accounting for significant explanatory variables. Conclusions: The axillary chemical dot, tympanic infrared and temporal scanner methods are inaccurate measures of core temperature in ICU patients. These non-invasive methods appeared unreliable for use in ICU patients.
format Online
Article
Text
id pubmed-10692569
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-106925692023-12-03 Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study Cutuli, Salvatore L. Osawa, Eduardo A. Eyeington, Christopher T. Proimos, Helena Canet, Emmanuel Young, Helen Peck, Leah Eastwood, Glenn M. Glassford, Neil J. Bailey, Michael Bellomo, Rinaldo Crit Care Resusc Original Article Objective: The accuracy of different non-invasive body temperature measurement methods in intensive care unit (ICU) patients is uncertain. We aimed to study the accuracy of three commonly used methods. Design: Prospective observational study. Setting: ICUs of two tertiary Australian hospitals. Participants: Critically ill patients admitted to the ICU. Interventions: Invasive (intravascular and intra-urinary bladder catheter) and non-invasive (axillary chemical dot, tympanic infrared, and temporal scanner) body temperature measurements were taken at study inclusion and every 4 hours for the following 72 hours. Main outcome measures: Accuracy of non-invasive body temperature measurement methods was assessed by the Bland–Altman approach, accounting for repeated measurements and significant explanatory variables that were identified by regression analysis. Clinical adequacy was set at limits of agreement (LoA) of 1°C compared with core temperature. Results: We studied 50 consecutive critically ill patients who were mainly admitted to the ICU after cardiac surgery. From over 375 observations, invasive core temperature (mostly pulmonary artery catheter) ranged from 33.9°C to 39°C. On average, the LoA between invasive and non-invasive measurements methods were about 3°C. The temporal scanner showed the worst performance in estimating core temperature (bias, 0.66°C; LoA, –1.23°C, +2.55°C), followed by tympanic infrared (bias, 0.44°C; LoA, –1.73°C, +2.61°C) and axillary chemical dot methods (bias, 0.32°C; LoA, –1.64°C, +2.28°C). No methods achieved clinical adequacy even accounting for significant explanatory variables. Conclusions: The axillary chemical dot, tympanic infrared and temporal scanner methods are inaccurate measures of core temperature in ICU patients. These non-invasive methods appeared unreliable for use in ICU patients. Elsevier 2023-10-18 /pmc/articles/PMC10692569/ /pubmed/38046071 http://dx.doi.org/10.51893/2021.3.OA12 Text en © 2021 College of Intensive Care Medicine of Australia and New Zealand. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Cutuli, Salvatore L.
Osawa, Eduardo A.
Eyeington, Christopher T.
Proimos, Helena
Canet, Emmanuel
Young, Helen
Peck, Leah
Eastwood, Glenn M.
Glassford, Neil J.
Bailey, Michael
Bellomo, Rinaldo
Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title_full Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title_fullStr Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title_full_unstemmed Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title_short Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
title_sort accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692569/
https://www.ncbi.nlm.nih.gov/pubmed/38046071
http://dx.doi.org/10.51893/2021.3.OA12
work_keys_str_mv AT cutulisalvatorel accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT osawaeduardoa accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT eyeingtonchristophert accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT proimoshelena accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT canetemmanuel accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT younghelen accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT peckleah accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT eastwoodglennm accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT glassfordneilj accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT baileymichael accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy
AT bellomorinaldo accuracyofnoninvasivebodytemperaturemeasurementmethodsincriticallyillpatientsaprospectivebicentricobservationalstudy