Cargando…
Can multiple miniplates improve the treatment of comminuted patellar fracture?
BACKGROUND: We have applied primarily multiple locking compression miniplates in treating multifragmentary, comminuted patellar fracture in combination with conventional fixation methods. METHODS: Medical and radiologic data were retrospectively reviewed for the patients surgically fixated with lock...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693109/ https://www.ncbi.nlm.nih.gov/pubmed/38042790 http://dx.doi.org/10.1186/s12891-023-07045-x |
_version_ | 1785153087399264256 |
---|---|
author | Yoo, Seung Jin Ok, Seungwoo Lee, Jaeryun Choi, Sungwook |
author_facet | Yoo, Seung Jin Ok, Seungwoo Lee, Jaeryun Choi, Sungwook |
author_sort | Yoo, Seung Jin |
collection | PubMed |
description | BACKGROUND: We have applied primarily multiple locking compression miniplates in treating multifragmentary, comminuted patellar fracture in combination with conventional fixation methods. METHODS: Medical and radiologic data were retrospectively reviewed for the patients surgically fixated with locking compression miniplates in patellar fracture of AO/OTA 34-C3. The primary outcome was bone union at the final follow-up, and the secondary outcomes were functional outcomes and postoperative complications associated with the procedure. For the functional assessment, the Lysholm score, Tegner scores, and the knee range of motion was compared. RESULTS: A total of twenty patients with AO/OTA 34-C3 patellar fracture were included in the study with an average follow-up period of 15 months (range:11 ~ 18 months) between June 2018 and November 2021. Eleven male and nine female patients presented an average age of 57.15 years. The primary fracture union was seen in all twenty patients, and the average time to the union was 15.6 weeks on serial radiograph follow-up. All patients did not show any postoperative complications, such as fixation failure, infection, or revision operations. Postoperatively, all patients achieved an average range of motion of 130 degrees, and the Lysholm and Tegners scores showed an average of 90.4 and 5.0 at the final follow-up, retrospectively. CONCLUSION: Fixations with miniplates in comminuted patellar fractures can be a useful option for effective osteosynthesis due to their versatile, efficient, and low-profile nature. |
format | Online Article Text |
id | pubmed-10693109 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-106931092023-12-03 Can multiple miniplates improve the treatment of comminuted patellar fracture? Yoo, Seung Jin Ok, Seungwoo Lee, Jaeryun Choi, Sungwook BMC Musculoskelet Disord Research BACKGROUND: We have applied primarily multiple locking compression miniplates in treating multifragmentary, comminuted patellar fracture in combination with conventional fixation methods. METHODS: Medical and radiologic data were retrospectively reviewed for the patients surgically fixated with locking compression miniplates in patellar fracture of AO/OTA 34-C3. The primary outcome was bone union at the final follow-up, and the secondary outcomes were functional outcomes and postoperative complications associated with the procedure. For the functional assessment, the Lysholm score, Tegner scores, and the knee range of motion was compared. RESULTS: A total of twenty patients with AO/OTA 34-C3 patellar fracture were included in the study with an average follow-up period of 15 months (range:11 ~ 18 months) between June 2018 and November 2021. Eleven male and nine female patients presented an average age of 57.15 years. The primary fracture union was seen in all twenty patients, and the average time to the union was 15.6 weeks on serial radiograph follow-up. All patients did not show any postoperative complications, such as fixation failure, infection, or revision operations. Postoperatively, all patients achieved an average range of motion of 130 degrees, and the Lysholm and Tegners scores showed an average of 90.4 and 5.0 at the final follow-up, retrospectively. CONCLUSION: Fixations with miniplates in comminuted patellar fractures can be a useful option for effective osteosynthesis due to their versatile, efficient, and low-profile nature. BioMed Central 2023-12-02 /pmc/articles/PMC10693109/ /pubmed/38042790 http://dx.doi.org/10.1186/s12891-023-07045-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yoo, Seung Jin Ok, Seungwoo Lee, Jaeryun Choi, Sungwook Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title | Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title_full | Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title_fullStr | Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title_full_unstemmed | Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title_short | Can multiple miniplates improve the treatment of comminuted patellar fracture? |
title_sort | can multiple miniplates improve the treatment of comminuted patellar fracture? |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693109/ https://www.ncbi.nlm.nih.gov/pubmed/38042790 http://dx.doi.org/10.1186/s12891-023-07045-x |
work_keys_str_mv | AT yooseungjin canmultipleminiplatesimprovethetreatmentofcomminutedpatellarfracture AT okseungwoo canmultipleminiplatesimprovethetreatmentofcomminutedpatellarfracture AT leejaeryun canmultipleminiplatesimprovethetreatmentofcomminutedpatellarfracture AT choisungwook canmultipleminiplatesimprovethetreatmentofcomminutedpatellarfracture |