Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI

Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of co...

Descripción completa

Detalles Bibliográficos
Autores principales: Kummari, Satyanarayana, Burra, Kiran Goud, Reddy, Vudem Ranjith Kumar, Das, Saraswata, Anilkumar, Challa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693390/
https://www.ncbi.nlm.nih.gov/pubmed/38046735
http://dx.doi.org/10.7759/cureus.48136
_version_ 1785153150501519360
author Kummari, Satyanarayana
Burra, Kiran Goud
Reddy, Vudem Ranjith Kumar
Das, Saraswata
Anilkumar, Challa
author_facet Kummari, Satyanarayana
Burra, Kiran Goud
Reddy, Vudem Ranjith Kumar
Das, Saraswata
Anilkumar, Challa
author_sort Kummari, Satyanarayana
collection PubMed
description Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of contiguous slices yielding improved signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). To our knowledge, there are only three studies comparing 3D- and 2D-FLAIR sequences with respect to multiple sclerosis (MS) lesions at 3 tesla. Aims and objectives: This study aimed to determine the efficiency of 3D-FLAIR in the detection of lesions of multiple sclerosis in terms of spatial and contrast resolutions in comparison with 2D-FLAIR sequences. Methodology: A total of 75 patients with MS undergoing magnetic resonance imaging (MRI) brain at the Department of Radiology, Krishna Institute of Medical Sciences (KIMS), Secunderabad, Telangana, India. This is an observational comparative study. Independent-samples t-tests were performed in the present study to compare the number of lesions detected. The measured CNR and SNR values were subjected to Mann-Whitney U test. Results: As a result of the 3D-FLAIR, more lesions were found as compared to 2D-FLAIR (p = 0.001). There was a greater CNRs for 3D-FLAIR images than for 2D-FLAIR images (p = 0.001). Lesions, CSF, white matter, and gray matter showed significantly higher SNRs with 3D-FLAIR (p = 0.001). Conclusion: 3D-FLAIR has exhibited greater sensitivity in detecting lesions associated with MS when contrasted with the 2D-FLAIR sequence. Significantly more lesions and higher SNRs and CNRs were detected with 3D-FLAIR in contrast to 2D-FLAIR. 3D-FLAIR may be considered the sequence of choice for MS imaging in the future.
format Online
Article
Text
id pubmed-10693390
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-106933902023-12-03 Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI Kummari, Satyanarayana Burra, Kiran Goud Reddy, Vudem Ranjith Kumar Das, Saraswata Anilkumar, Challa Cureus Neurology Background: A fluid-attenuated inversion recovery (FLAIR) method eliminates the cerebrospinal fluid (CSF) signal, enhancing white matter lesion detection by enhancing the contrast between the lesion and CSF. Three-dimensional (3D) volume acquisition has the advantage of multiplanar reformation of contiguous slices yielding improved signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs). To our knowledge, there are only three studies comparing 3D- and 2D-FLAIR sequences with respect to multiple sclerosis (MS) lesions at 3 tesla. Aims and objectives: This study aimed to determine the efficiency of 3D-FLAIR in the detection of lesions of multiple sclerosis in terms of spatial and contrast resolutions in comparison with 2D-FLAIR sequences. Methodology: A total of 75 patients with MS undergoing magnetic resonance imaging (MRI) brain at the Department of Radiology, Krishna Institute of Medical Sciences (KIMS), Secunderabad, Telangana, India. This is an observational comparative study. Independent-samples t-tests were performed in the present study to compare the number of lesions detected. The measured CNR and SNR values were subjected to Mann-Whitney U test. Results: As a result of the 3D-FLAIR, more lesions were found as compared to 2D-FLAIR (p = 0.001). There was a greater CNRs for 3D-FLAIR images than for 2D-FLAIR images (p = 0.001). Lesions, CSF, white matter, and gray matter showed significantly higher SNRs with 3D-FLAIR (p = 0.001). Conclusion: 3D-FLAIR has exhibited greater sensitivity in detecting lesions associated with MS when contrasted with the 2D-FLAIR sequence. Significantly more lesions and higher SNRs and CNRs were detected with 3D-FLAIR in contrast to 2D-FLAIR. 3D-FLAIR may be considered the sequence of choice for MS imaging in the future. Cureus 2023-11-01 /pmc/articles/PMC10693390/ /pubmed/38046735 http://dx.doi.org/10.7759/cureus.48136 Text en Copyright © 2023, Kummari et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Neurology
Kummari, Satyanarayana
Burra, Kiran Goud
Reddy, Vudem Ranjith Kumar
Das, Saraswata
Anilkumar, Challa
Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title_full Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title_fullStr Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title_full_unstemmed Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title_short Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
title_sort determination of efficiency of 3d fluid-attenuated inversion recovery (flair) in the imaging of multiple sclerosis in comparison with 2d flair at 3-tesla mri
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693390/
https://www.ncbi.nlm.nih.gov/pubmed/38046735
http://dx.doi.org/10.7759/cureus.48136
work_keys_str_mv AT kummarisatyanarayana determinationofefficiencyof3dfluidattenuatedinversionrecoveryflairintheimagingofmultiplesclerosisincomparisonwith2dflairat3teslamri
AT burrakirangoud determinationofefficiencyof3dfluidattenuatedinversionrecoveryflairintheimagingofmultiplesclerosisincomparisonwith2dflairat3teslamri
AT reddyvudemranjithkumar determinationofefficiencyof3dfluidattenuatedinversionrecoveryflairintheimagingofmultiplesclerosisincomparisonwith2dflairat3teslamri
AT dassaraswata determinationofefficiencyof3dfluidattenuatedinversionrecoveryflairintheimagingofmultiplesclerosisincomparisonwith2dflairat3teslamri
AT anilkumarchalla determinationofefficiencyof3dfluidattenuatedinversionrecoveryflairintheimagingofmultiplesclerosisincomparisonwith2dflairat3teslamri