Cargando…

Pulsed Thulium:YAG laser – What is the lithotripsy ablation efficiency for stone dust from human urinary stones? Results from an in vitro PEARLS study

BACKGROUND: The novel pulsed thulium:yttrium–aluminum–garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG abla...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwok, Jia-Lun, Ventimiglia, Eugenio, De Coninck, Vincent, Panthier, Frédéric, Barghouthy, Yazeed, Danilovic, Alexandre, Shrestha, Anil, Smyth, Niamh, Schmid, Florian Alexander, Hunziker, Manuela, Poyet, Cédric, Daudon, Michel, Traxer, Olivier, Eberli, Daniel, Keller, Etienne Xavier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693514/
https://www.ncbi.nlm.nih.gov/pubmed/37831156
http://dx.doi.org/10.1007/s00345-023-04640-4
Descripción
Sumario:BACKGROUND: The novel pulsed thulium:yttrium–aluminum–garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm(3), UA: 1.55 mg/mm(3)). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm(3)/J (COM) and 0.026, 0.030, 0.039 mm(3)/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm(3) (COM) and 50, 36, 26 J/mm(3) (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.