Cargando…
In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners
OBJECTIVE: To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign(®) appliances, both retrieved as well as in the ‘as-received’ control status. DESIGN: An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS: Twelve clinically use...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693732/ https://www.ncbi.nlm.nih.gov/pubmed/36573484 http://dx.doi.org/10.1177/14653125221145948 |
_version_ | 1785153225505112064 |
---|---|
author | Koletsi, Despina Panayi, Nearchos Laspos, Christodoulos Athanasiou, Athanasios E Zinelis, Spiros Eliades, Theodore |
author_facet | Koletsi, Despina Panayi, Nearchos Laspos, Christodoulos Athanasiou, Athanasios E Zinelis, Spiros Eliades, Theodore |
author_sort | Koletsi, Despina |
collection | PubMed |
description | OBJECTIVE: To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign(®) appliances, both retrieved as well as in the ‘as-received’ control status. DESIGN: An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS: Twelve clinically used Invisalign(®) appliances and the same number of 3D-printed aligners, without involvement of attachments, were obtained from a respective number of patients. A similar number of ‘as-received’ aligners, of each material, were used as control (CON) groups. METHOD: Four groups of materials were examined: A = Invisalign(®) CON; B = Invisalign(®) used; C = 3D-printed CON; and D = 3D-printed used. Optical profilometry was employed to examine the following surface roughness parameters: amplitude parameters Sa, Sq and Sz and functional parameters Sc and Sv. Descriptive statistics and quantile regression modeling were conducted, and the level of statistical significance was set at α = 0.05. RESULTS: Intra-oral exposure of 3D-printed aligners was significantly associated with increase in all tested parameters (P < 0.001 at all occasions). Significant differences were detected in the retrieved 3D-printed aligners compared with Invisalign(®) retrieved, with the exception of Sz. The respective effect sizes (median differences) were as follows: Sa: 169 nm, 95% confidence interval [CI] = 89–248, P < 0.001; Sq: 315 nm, 95% CI = 152–477, P < 0.001; Sc: 233 nm(3)/nm(2), 95% CI = 131–335, P < 0.001; and Sv: 43 nm(3)/nm(2), 95% CI = 17–68, P = 0.002. CONCLUSION: Within the limitations of this study, we concluded that surface roughness differences existed between 3D-printed aligners and Invisalign(®) in the retrieved status, as well as between the control and retrieved 3D-printed groups. |
format | Online Article Text |
id | pubmed-10693732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-106937322023-12-04 In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners Koletsi, Despina Panayi, Nearchos Laspos, Christodoulos Athanasiou, Athanasios E Zinelis, Spiros Eliades, Theodore J Orthod Scientific Section OBJECTIVE: To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign(®) appliances, both retrieved as well as in the ‘as-received’ control status. DESIGN: An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS: Twelve clinically used Invisalign(®) appliances and the same number of 3D-printed aligners, without involvement of attachments, were obtained from a respective number of patients. A similar number of ‘as-received’ aligners, of each material, were used as control (CON) groups. METHOD: Four groups of materials were examined: A = Invisalign(®) CON; B = Invisalign(®) used; C = 3D-printed CON; and D = 3D-printed used. Optical profilometry was employed to examine the following surface roughness parameters: amplitude parameters Sa, Sq and Sz and functional parameters Sc and Sv. Descriptive statistics and quantile regression modeling were conducted, and the level of statistical significance was set at α = 0.05. RESULTS: Intra-oral exposure of 3D-printed aligners was significantly associated with increase in all tested parameters (P < 0.001 at all occasions). Significant differences were detected in the retrieved 3D-printed aligners compared with Invisalign(®) retrieved, with the exception of Sz. The respective effect sizes (median differences) were as follows: Sa: 169 nm, 95% confidence interval [CI] = 89–248, P < 0.001; Sq: 315 nm, 95% CI = 152–477, P < 0.001; Sc: 233 nm(3)/nm(2), 95% CI = 131–335, P < 0.001; and Sv: 43 nm(3)/nm(2), 95% CI = 17–68, P = 0.002. CONCLUSION: Within the limitations of this study, we concluded that surface roughness differences existed between 3D-printed aligners and Invisalign(®) in the retrieved status, as well as between the control and retrieved 3D-printed groups. SAGE Publications 2022-12-27 2023-12 /pmc/articles/PMC10693732/ /pubmed/36573484 http://dx.doi.org/10.1177/14653125221145948 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Scientific Section Koletsi, Despina Panayi, Nearchos Laspos, Christodoulos Athanasiou, Athanasios E Zinelis, Spiros Eliades, Theodore In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title | In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title_full | In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title_fullStr | In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title_full_unstemmed | In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title_short | In vivo aging-induced surface roughness alterations of Invisalign(®) and 3D-printed aligners |
title_sort | in vivo aging-induced surface roughness alterations of invisalign(®) and 3d-printed aligners |
topic | Scientific Section |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693732/ https://www.ncbi.nlm.nih.gov/pubmed/36573484 http://dx.doi.org/10.1177/14653125221145948 |
work_keys_str_mv | AT koletsidespina invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners AT panayinearchos invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners AT lasposchristodoulos invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners AT athanasiouathanasiose invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners AT zinelisspiros invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners AT eliadestheodore invivoaginginducedsurfaceroughnessalterationsofinvisalignand3dprintedaligners |