Cargando…

Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture

PURPOSE: To present a modified technique of 4-point scleral fixation using polymethyl methacrylate (PMMA) 2 eyelets intraocular lens (IOL) with 8-0 polypropylene sutures. METHODS: A 270-degree conjunctival peritomy is done, and 4 sclerotomies (2 nasal and 2 temporal) are created. Lamellar scleral or...

Descripción completa

Detalles Bibliográficos
Autores principales: Angsana, Natalia Christina, Wardhana, Firman Setya, Supanji, Prayogo, Mohammad Eko, Sasongko, Muhammad Bayu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693757/
https://www.ncbi.nlm.nih.gov/pubmed/38050556
http://dx.doi.org/10.2147/OPTH.S426443
_version_ 1785153231053127680
author Angsana, Natalia Christina
Wardhana, Firman Setya
Supanji
Prayogo, Mohammad Eko
Sasongko, Muhammad Bayu
author_facet Angsana, Natalia Christina
Wardhana, Firman Setya
Supanji
Prayogo, Mohammad Eko
Sasongko, Muhammad Bayu
author_sort Angsana, Natalia Christina
collection PubMed
description PURPOSE: To present a modified technique of 4-point scleral fixation using polymethyl methacrylate (PMMA) 2 eyelets intraocular lens (IOL) with 8-0 polypropylene sutures. METHODS: A 270-degree conjunctival peritomy is done, and 4 sclerotomies (2 nasal and 2 temporal) are created. Lamellar scleral or clear corneal incision is made at superior site (6 mm wide for sclera or 5.5–6 mm for corneal). A short segment of 8-0 polypropylene is inserted into each eyelet, each thread of the suture is externalized through the sclerotomy site, and the lens is inserted. The suture is tightened evenly, and the knot is rotated and internalized. Scleral incision and conjunctival peritomy are sutured with 8-0 vicryl. RESULTS: We have performed this technique in 6 patients with excellent visual outcomes and no reported complications over 1 year of follow-up. This technique has practical advantages including rigid and stable PMMA IOL, high tensile, and slim 8-0 polypropylene suture which is easily internalized and less irritated, and affordable and widely available overall consumables. CONCLUSION: We present a modified 4-point scleral fixation technique for posterior chamber IOL placement using PMMA IOL with 2 eyelets and 8-0 polypropylene as compared to previous studies that used foldable IOL with 4 eyelets and 10-0 polypropylene or Gore-Tex sutures. This procedure has moderate technical complexity, comparable to previously reported techniques with good overall clinical outcomes and several practical advantages, particularly related to the affordability and availability of the consumables.
format Online
Article
Text
id pubmed-10693757
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-106937572023-12-04 Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture Angsana, Natalia Christina Wardhana, Firman Setya Supanji Prayogo, Mohammad Eko Sasongko, Muhammad Bayu Clin Ophthalmol Methodology PURPOSE: To present a modified technique of 4-point scleral fixation using polymethyl methacrylate (PMMA) 2 eyelets intraocular lens (IOL) with 8-0 polypropylene sutures. METHODS: A 270-degree conjunctival peritomy is done, and 4 sclerotomies (2 nasal and 2 temporal) are created. Lamellar scleral or clear corneal incision is made at superior site (6 mm wide for sclera or 5.5–6 mm for corneal). A short segment of 8-0 polypropylene is inserted into each eyelet, each thread of the suture is externalized through the sclerotomy site, and the lens is inserted. The suture is tightened evenly, and the knot is rotated and internalized. Scleral incision and conjunctival peritomy are sutured with 8-0 vicryl. RESULTS: We have performed this technique in 6 patients with excellent visual outcomes and no reported complications over 1 year of follow-up. This technique has practical advantages including rigid and stable PMMA IOL, high tensile, and slim 8-0 polypropylene suture which is easily internalized and less irritated, and affordable and widely available overall consumables. CONCLUSION: We present a modified 4-point scleral fixation technique for posterior chamber IOL placement using PMMA IOL with 2 eyelets and 8-0 polypropylene as compared to previous studies that used foldable IOL with 4 eyelets and 10-0 polypropylene or Gore-Tex sutures. This procedure has moderate technical complexity, comparable to previously reported techniques with good overall clinical outcomes and several practical advantages, particularly related to the affordability and availability of the consumables. Dove 2023-11-29 /pmc/articles/PMC10693757/ /pubmed/38050556 http://dx.doi.org/10.2147/OPTH.S426443 Text en © 2023 Angsana et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Methodology
Angsana, Natalia Christina
Wardhana, Firman Setya
Supanji
Prayogo, Mohammad Eko
Sasongko, Muhammad Bayu
Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title_full Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title_fullStr Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title_full_unstemmed Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title_short Modified Four-Point Scleral Fixated Sutured Posterior Chamber Intraocular Lens Implantation Using 2 Eyelets Polymethyl Methacrylate Lens and 8-0 Polypropylene Suture
title_sort modified four-point scleral fixated sutured posterior chamber intraocular lens implantation using 2 eyelets polymethyl methacrylate lens and 8-0 polypropylene suture
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10693757/
https://www.ncbi.nlm.nih.gov/pubmed/38050556
http://dx.doi.org/10.2147/OPTH.S426443
work_keys_str_mv AT angsananataliachristina modifiedfourpointscleralfixatedsuturedposteriorchamberintraocularlensimplantationusing2eyeletspolymethylmethacrylatelensand80polypropylenesuture
AT wardhanafirmansetya modifiedfourpointscleralfixatedsuturedposteriorchamberintraocularlensimplantationusing2eyeletspolymethylmethacrylatelensand80polypropylenesuture
AT supanji modifiedfourpointscleralfixatedsuturedposteriorchamberintraocularlensimplantationusing2eyeletspolymethylmethacrylatelensand80polypropylenesuture
AT prayogomohammadeko modifiedfourpointscleralfixatedsuturedposteriorchamberintraocularlensimplantationusing2eyeletspolymethylmethacrylatelensand80polypropylenesuture
AT sasongkomuhammadbayu modifiedfourpointscleralfixatedsuturedposteriorchamberintraocularlensimplantationusing2eyeletspolymethylmethacrylatelensand80polypropylenesuture