In liver stereotactic body radiotherapy (SBRT), precise image guidance is paramount, serving as the foundation of this treatment approach. The accuracy of SBRT in liver cancer treatment heavily relies on meticulous imaging techniques. The diaphragm, situated adjacent to the liver, is a crucial anato...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10695080/ http://dx.doi.org/10.7759/cureus.48188 |
_version_ | 1785153514594369536 |
---|---|
author | Katano, Atsuto Nozawa, Yuki Minamitani, Masanari Ohira, Shingo Nakagawa, Keiichi |
author_facet | Katano, Atsuto Nozawa, Yuki Minamitani, Masanari Ohira, Shingo Nakagawa, Keiichi |
author_sort | Katano, Atsuto |
collection | PubMed |
description | In liver stereotactic body radiotherapy (SBRT), precise image guidance is paramount, serving as the foundation of this treatment approach. The accuracy of SBRT in liver cancer treatment heavily relies on meticulous imaging techniques. The diaphragm, situated adjacent to the liver, is a crucial anatomical structure susceptible to positional and motion variations, which can potentially impact the accuracy of liver tumor targeting. This study explores the application of real-time kilovoltage projection streaming images (KVPSI) in comparison to digitally reconstructed radiography (DRR) for assessing diaphragm position deviations during breath-hold liver tumor SBRT. A 76-year-old male diagnosed with cholangiocarcinoma underwent breath-hold SBRT using split arc volumetric modulated arc therapy (VMAT), where a full arc was split into six sub-arcs, each spanning 60 degrees. The diaphragm dome positions were continuously monitored through KVPSI during treatment. The intrafractional position deviations of the diaphragm were calculated and analyzed for each split arc. The case report revealed a mean diaphragm dome deviation of 0.47 mm (standard deviation: 4.47 mm) in the entire arc. This pioneering study showcases the feasibility of intrafractional diaphragm position variation assessment using real-time KVPSI during the breath-hold liver tumor VMAT-SBRT. Integrating real-time imaging techniques enhances our comprehension of the intra-breath-hold variations, thereby guiding adaptive treatment strategies and potentially improving treatment outcomes. Clinical validation through further research is essential. |
format | Online Article Text |
id | pubmed-10695080 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-106950802023-12-05 Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report Katano, Atsuto Nozawa, Yuki Minamitani, Masanari Ohira, Shingo Nakagawa, Keiichi Cureus Radiation Oncology In liver stereotactic body radiotherapy (SBRT), precise image guidance is paramount, serving as the foundation of this treatment approach. The accuracy of SBRT in liver cancer treatment heavily relies on meticulous imaging techniques. The diaphragm, situated adjacent to the liver, is a crucial anatomical structure susceptible to positional and motion variations, which can potentially impact the accuracy of liver tumor targeting. This study explores the application of real-time kilovoltage projection streaming images (KVPSI) in comparison to digitally reconstructed radiography (DRR) for assessing diaphragm position deviations during breath-hold liver tumor SBRT. A 76-year-old male diagnosed with cholangiocarcinoma underwent breath-hold SBRT using split arc volumetric modulated arc therapy (VMAT), where a full arc was split into six sub-arcs, each spanning 60 degrees. The diaphragm dome positions were continuously monitored through KVPSI during treatment. The intrafractional position deviations of the diaphragm were calculated and analyzed for each split arc. The case report revealed a mean diaphragm dome deviation of 0.47 mm (standard deviation: 4.47 mm) in the entire arc. This pioneering study showcases the feasibility of intrafractional diaphragm position variation assessment using real-time KVPSI during the breath-hold liver tumor VMAT-SBRT. Integrating real-time imaging techniques enhances our comprehension of the intra-breath-hold variations, thereby guiding adaptive treatment strategies and potentially improving treatment outcomes. Clinical validation through further research is essential. Cureus 2023-11-02 /pmc/articles/PMC10695080/ http://dx.doi.org/10.7759/cureus.48188 Text en Copyright © 2023, Katano et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Radiation Oncology Katano, Atsuto Nozawa, Yuki Minamitani, Masanari Ohira, Shingo Nakagawa, Keiichi Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title | Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title_full | Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title_fullStr | Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title_full_unstemmed | Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title_short | Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report |
title_sort | intrafractional diaphragm variations during breath-hold stereotactic body radiotherapy for a liver tumor based on real-time registration between kilovoltage projection streaming and digitally reconstructed radiograph images: a case report |
topic | Radiation Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10695080/ http://dx.doi.org/10.7759/cureus.48188 |
work_keys_str_mv | AT katanoatsuto intrafractionaldiaphragmvariationsduringbreathholdstereotacticbodyradiotherapyforalivertumorbasedonrealtimeregistrationbetweenkilovoltageprojectionstreaminganddigitallyreconstructedradiographimagesacasereport AT nozawayuki intrafractionaldiaphragmvariationsduringbreathholdstereotacticbodyradiotherapyforalivertumorbasedonrealtimeregistrationbetweenkilovoltageprojectionstreaminganddigitallyreconstructedradiographimagesacasereport AT minamitanimasanari intrafractionaldiaphragmvariationsduringbreathholdstereotacticbodyradiotherapyforalivertumorbasedonrealtimeregistrationbetweenkilovoltageprojectionstreaminganddigitallyreconstructedradiographimagesacasereport AT ohirashingo intrafractionaldiaphragmvariationsduringbreathholdstereotacticbodyradiotherapyforalivertumorbasedonrealtimeregistrationbetweenkilovoltageprojectionstreaminganddigitallyreconstructedradiographimagesacasereport AT nakagawakeiichi intrafractionaldiaphragmvariationsduringbreathholdstereotacticbodyradiotherapyforalivertumorbasedonrealtimeregistrationbetweenkilovoltageprojectionstreaminganddigitallyreconstructedradiographimagesacasereport |