Cargando…

Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial

BACKGROUND: The present study aimed to evaluate the degree of radiation shielding effects according to lead equivalent thickness and distance during C-arm fluoroscopy-guided lumbar interventions. METHODS: The exposure time and air kerma were recorded using a fluoroscope. The effective dose (ED) was...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Cho Long, Jeong, Hae Chang, Kim, Jae Hun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10695529/
http://dx.doi.org/10.1097/MD.0000000000036447
_version_ 1785153585447698432
author Kim, Cho Long
Jeong, Hae Chang
Kim, Jae Hun
author_facet Kim, Cho Long
Jeong, Hae Chang
Kim, Jae Hun
author_sort Kim, Cho Long
collection PubMed
description BACKGROUND: The present study aimed to evaluate the degree of radiation shielding effects according to lead equivalent thickness and distance during C-arm fluoroscopy-guided lumbar interventions. METHODS: The exposure time and air kerma were recorded using a fluoroscope. The effective dose (ED) was measured with and without the shielding material of the lead apron using 2 dosimeters at 2 positions. According to the lead equivalent thickness of the shielding material and distance from the side of the table, the groups were divided into 4 groups: group 1 (lead equivalent thickness 0.6 mm, distance 0 cm), group 2 (lead equivalent thickness 0.6 mm, distance 5 cm), group 3 (lead equivalent thickness 0.3 mm, distance 0 cm), and group 4 (lead equivalent thickness 0.3 mm, distance 5 cm). Mean differences such as air kerma, exposure time, ED, and ratio of EDs (ED with protector/ED without protector) were analyzed. RESULTS: A total of 400 cases (100 cases in each group) were collected. The ratio of ED was significantly lower in groups 1 and 2 (9.18 ± 2.78% and 9.56 ± 3.29%, respectively) when compared to that of groups 3 and 4 (21.93 ± 4.19% and 21.53 ± 4.30%, respectively). The reductive effect of a 5-cm distance was 33.3% to 36.1% when comparing the ED between groups 1 and 2 and groups 3 and 4. CONCLUSIONS: The 0.3- and 0.6-mm lead equivalent thickness protectors have a radiation attenuation effect of 78.1% to 78.5% and 90.4% to 90.8%, respectively. The 5-cm distance from the side of the table reduces radiation exposure by 33.3% to 36.1%.
format Online
Article
Text
id pubmed-10695529
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-106955292023-12-05 Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial Kim, Cho Long Jeong, Hae Chang Kim, Jae Hun Medicine (Baltimore) 3300 BACKGROUND: The present study aimed to evaluate the degree of radiation shielding effects according to lead equivalent thickness and distance during C-arm fluoroscopy-guided lumbar interventions. METHODS: The exposure time and air kerma were recorded using a fluoroscope. The effective dose (ED) was measured with and without the shielding material of the lead apron using 2 dosimeters at 2 positions. According to the lead equivalent thickness of the shielding material and distance from the side of the table, the groups were divided into 4 groups: group 1 (lead equivalent thickness 0.6 mm, distance 0 cm), group 2 (lead equivalent thickness 0.6 mm, distance 5 cm), group 3 (lead equivalent thickness 0.3 mm, distance 0 cm), and group 4 (lead equivalent thickness 0.3 mm, distance 5 cm). Mean differences such as air kerma, exposure time, ED, and ratio of EDs (ED with protector/ED without protector) were analyzed. RESULTS: A total of 400 cases (100 cases in each group) were collected. The ratio of ED was significantly lower in groups 1 and 2 (9.18 ± 2.78% and 9.56 ± 3.29%, respectively) when compared to that of groups 3 and 4 (21.93 ± 4.19% and 21.53 ± 4.30%, respectively). The reductive effect of a 5-cm distance was 33.3% to 36.1% when comparing the ED between groups 1 and 2 and groups 3 and 4. CONCLUSIONS: The 0.3- and 0.6-mm lead equivalent thickness protectors have a radiation attenuation effect of 78.1% to 78.5% and 90.4% to 90.8%, respectively. The 5-cm distance from the side of the table reduces radiation exposure by 33.3% to 36.1%. Lippincott Williams & Wilkins 2023-12-01 /pmc/articles/PMC10695529/ http://dx.doi.org/10.1097/MD.0000000000036447 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 3300
Kim, Cho Long
Jeong, Hae Chang
Kim, Jae Hun
Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title_full Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title_fullStr Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title_full_unstemmed Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title_short Radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during C-arm fluoroscopy-guided pain interventions: A randomized trial
title_sort radiation shielding effects of lead equivalent thickness of a radiation protective apron and distance during c-arm fluoroscopy-guided pain interventions: a randomized trial
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10695529/
http://dx.doi.org/10.1097/MD.0000000000036447
work_keys_str_mv AT kimcholong radiationshieldingeffectsofleadequivalentthicknessofaradiationprotectiveapronanddistanceduringcarmfluoroscopyguidedpaininterventionsarandomizedtrial
AT jeonghaechang radiationshieldingeffectsofleadequivalentthicknessofaradiationprotectiveapronanddistanceduringcarmfluoroscopyguidedpaininterventionsarandomizedtrial
AT kimjaehun radiationshieldingeffectsofleadequivalentthicknessofaradiationprotectiveapronanddistanceduringcarmfluoroscopyguidedpaininterventionsarandomizedtrial