Cargando…

Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis

BACKGROUND: Herpes simplex keratitis (HSK) is a sight threatening ocular infection often requiring a specific and prompt laboratory diagnosis. Isolation of Herpes simplex virus (HSV-1) in culture provides the most reliable and specific method and is considered as the "Gold Standard" in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Athmanathan, Sreedharan, B Reddy, Sesha, Nutheti, Rishita, Rao, Gullapalli N
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC113264/
https://www.ncbi.nlm.nih.gov/pubmed/11983023
http://dx.doi.org/10.1186/1471-2415-2-3
_version_ 1782120235350884352
author Athmanathan, Sreedharan
B Reddy, Sesha
Nutheti, Rishita
Rao, Gullapalli N
author_facet Athmanathan, Sreedharan
B Reddy, Sesha
Nutheti, Rishita
Rao, Gullapalli N
author_sort Athmanathan, Sreedharan
collection PubMed
description BACKGROUND: Herpes simplex keratitis (HSK) is a sight threatening ocular infection often requiring a specific and prompt laboratory diagnosis. Isolation of Herpes simplex virus (HSV-1) in culture provides the most reliable and specific method and is considered as the "Gold Standard" in the laboratory diagnosis of HSK in spite of its low sensitivity. Using "cell lines of corneal origin" for virus isolation may be beneficial under such circumstances, since these cells have been shown to be excellent substrates for the growth of HSV-1 isolated from the cornea. We report a comparative study of a novel human corneal epithelial cell line (HCE) and the Vero cell line in the isolation of HSV-1 from corneal scrapings employing a shell vial assay. METHODS: Corneal scrapings were obtained from 17 patients with a clinical diagnosis of HSK. All the cases were confirmed by virological investigations (PCR and viral antigen detection positive, n = 15, PCR positive, n = 1, Viral antigen positive, n = 1). Scrapings obtained from 10 patients with infectious keratitis of non-viral origin were included as controls. All the scrapings were simultaneously inoculated into shell vials of HCE and Vero cells. Cultures were terminated at 24 h post-infection. Isolation of HSV-1 was confirmed using an indirect immunofluorescence/ immunoperoxidase assay. RESULTS: Virus could be isolated using both or either of the cell lines in 10/17 (58.82%) patients with HSK. HSV-1 was isolated from 10/ 17 (58.82%) and 4/17(23.52%) specimens in HCE and Vero cells, respectively (P = 0.036). None of the controls yielded HSV-1. While all the 10 (100%) strains were isolated in HCE, Vero yielded only 4/10 (40%) strains in the shell vial culture (P = 0.014). CONCLUSIONS: HCE showed a statistically significant difference in the virus isolation rate with respect to Vero cells. HCE may be an excellent alternative cell line for the isolation of HSV-1, especially from corneal scrapings, for the laboratory diagnosis of HSK.
format Text
id pubmed-113264
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-1132642002-05-23 Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis Athmanathan, Sreedharan B Reddy, Sesha Nutheti, Rishita Rao, Gullapalli N BMC Ophthalmol Research Article BACKGROUND: Herpes simplex keratitis (HSK) is a sight threatening ocular infection often requiring a specific and prompt laboratory diagnosis. Isolation of Herpes simplex virus (HSV-1) in culture provides the most reliable and specific method and is considered as the "Gold Standard" in the laboratory diagnosis of HSK in spite of its low sensitivity. Using "cell lines of corneal origin" for virus isolation may be beneficial under such circumstances, since these cells have been shown to be excellent substrates for the growth of HSV-1 isolated from the cornea. We report a comparative study of a novel human corneal epithelial cell line (HCE) and the Vero cell line in the isolation of HSV-1 from corneal scrapings employing a shell vial assay. METHODS: Corneal scrapings were obtained from 17 patients with a clinical diagnosis of HSK. All the cases were confirmed by virological investigations (PCR and viral antigen detection positive, n = 15, PCR positive, n = 1, Viral antigen positive, n = 1). Scrapings obtained from 10 patients with infectious keratitis of non-viral origin were included as controls. All the scrapings were simultaneously inoculated into shell vials of HCE and Vero cells. Cultures were terminated at 24 h post-infection. Isolation of HSV-1 was confirmed using an indirect immunofluorescence/ immunoperoxidase assay. RESULTS: Virus could be isolated using both or either of the cell lines in 10/17 (58.82%) patients with HSK. HSV-1 was isolated from 10/ 17 (58.82%) and 4/17(23.52%) specimens in HCE and Vero cells, respectively (P = 0.036). None of the controls yielded HSV-1. While all the 10 (100%) strains were isolated in HCE, Vero yielded only 4/10 (40%) strains in the shell vial culture (P = 0.014). CONCLUSIONS: HCE showed a statistically significant difference in the virus isolation rate with respect to Vero cells. HCE may be an excellent alternative cell line for the isolation of HSV-1, especially from corneal scrapings, for the laboratory diagnosis of HSK. BioMed Central 2002-04-30 /pmc/articles/PMC113264/ /pubmed/11983023 http://dx.doi.org/10.1186/1471-2415-2-3 Text en Copyright © 2002 Athmanathan et al; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
Athmanathan, Sreedharan
B Reddy, Sesha
Nutheti, Rishita
Rao, Gullapalli N
Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title_full Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title_fullStr Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title_full_unstemmed Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title_short Comparison of an immortalized human corneal epithelial cell line with Vero cells in the isolation of Herpes simplex virus-1 for the laboratory diagnosis of Herpes simplex keratitis
title_sort comparison of an immortalized human corneal epithelial cell line with vero cells in the isolation of herpes simplex virus-1 for the laboratory diagnosis of herpes simplex keratitis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC113264/
https://www.ncbi.nlm.nih.gov/pubmed/11983023
http://dx.doi.org/10.1186/1471-2415-2-3
work_keys_str_mv AT athmanathansreedharan comparisonofanimmortalizedhumancornealepithelialcelllinewithverocellsintheisolationofherpessimplexvirus1forthelaboratorydiagnosisofherpessimplexkeratitis
AT breddysesha comparisonofanimmortalizedhumancornealepithelialcelllinewithverocellsintheisolationofherpessimplexvirus1forthelaboratorydiagnosisofherpessimplexkeratitis
AT nuthetirishita comparisonofanimmortalizedhumancornealepithelialcelllinewithverocellsintheisolationofherpessimplexvirus1forthelaboratorydiagnosisofherpessimplexkeratitis
AT raogullapallin comparisonofanimmortalizedhumancornealepithelialcelllinewithverocellsintheisolationofherpessimplexvirus1forthelaboratorydiagnosisofherpessimplexkeratitis