The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.

In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceilin...

Descripción completa

Detalles Bibliográficos
Autores principales: Ko, Gwangpyo, First, Melvin W, Burge, Harriet A
Formato: Texto
Lenguaje:English
Publicado: 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1240698/
https://www.ncbi.nlm.nih.gov/pubmed/11781170
_version_ 1782125206695837696
author Ko, Gwangpyo
First, Melvin W
Burge, Harriet A
author_facet Ko, Gwangpyo
First, Melvin W
Burge, Harriet A
author_sort Ko, Gwangpyo
collection PubMed
description In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceiling- and wall-mounted UV fixtures (UV output: 10W and 5W respectively) were installed. The use of ceiling- and wall-mounted UV fixtures (total UV output: 15W) without mixing fan reduced the concentration of S. marcescens aerosols by 46% (range: 22-80%) at 2 air changes per hour (ACH) and 53% (range: 40-68%) at 6 ACH. The use of ceiling- and wall-mounted UV fixtures with mixing fan increased the UV effectiveness in inactivating S. marcescens aerosols to 62% (range: 50-78%) at 2 ACH and to 86% (81-89%) at 6 ACH. For BCG aerosols, UV effectiveness in inactivating BCG aerosols at 6 ACH were 52% (range: 11-69%) by ceiling-mounted UV fixture only (total UV output: 10W) and 64% (51-83%) by both ceiling- and wall-mounted UV fixtures (total UV output: 15W). Our results indicated that the equivalent ventilation rate attributable to upper-room UVGI for BCG aerosols ranged from 1 ACH to 22 ACH for ceiling-mounted UV fixtures and from 6.4 ACH to 28.5 ACH for ceiling- and wall-mounted UV fixtures. Both generalized linear and generalized additive models were fitted to all our data. The regression results indicated that the number of UV fixtures, use of mixing fan, and air exchange rate significantly affected UV effectiveness (p < 0.01, 0.01, 0.01 respectively). However, the strain difference (S. marcescens vs. BCG) appeared less important in UV effectiveness (p = 0.26). Our results also indicated that UV effectiveness increased at higher temperature ((italic)p(/italic) < 0.01), lower dry-bulb temperature ((italic)p(/italic) = 0.21), and colder air from a supply grill located near the ceiling (p = 0.22).
format Text
id pubmed-1240698
institution National Center for Biotechnology Information
language English
publishDate 2002
record_format MEDLINE/PubMed
spelling pubmed-12406982005-11-08 The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms. Ko, Gwangpyo First, Melvin W Burge, Harriet A Environ Health Perspect Research Article In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceiling- and wall-mounted UV fixtures (UV output: 10W and 5W respectively) were installed. The use of ceiling- and wall-mounted UV fixtures (total UV output: 15W) without mixing fan reduced the concentration of S. marcescens aerosols by 46% (range: 22-80%) at 2 air changes per hour (ACH) and 53% (range: 40-68%) at 6 ACH. The use of ceiling- and wall-mounted UV fixtures with mixing fan increased the UV effectiveness in inactivating S. marcescens aerosols to 62% (range: 50-78%) at 2 ACH and to 86% (81-89%) at 6 ACH. For BCG aerosols, UV effectiveness in inactivating BCG aerosols at 6 ACH were 52% (range: 11-69%) by ceiling-mounted UV fixture only (total UV output: 10W) and 64% (51-83%) by both ceiling- and wall-mounted UV fixtures (total UV output: 15W). Our results indicated that the equivalent ventilation rate attributable to upper-room UVGI for BCG aerosols ranged from 1 ACH to 22 ACH for ceiling-mounted UV fixtures and from 6.4 ACH to 28.5 ACH for ceiling- and wall-mounted UV fixtures. Both generalized linear and generalized additive models were fitted to all our data. The regression results indicated that the number of UV fixtures, use of mixing fan, and air exchange rate significantly affected UV effectiveness (p < 0.01, 0.01, 0.01 respectively). However, the strain difference (S. marcescens vs. BCG) appeared less important in UV effectiveness (p = 0.26). Our results also indicated that UV effectiveness increased at higher temperature ((italic)p(/italic) < 0.01), lower dry-bulb temperature ((italic)p(/italic) = 0.21), and colder air from a supply grill located near the ceiling (p = 0.22). 2002-01 /pmc/articles/PMC1240698/ /pubmed/11781170 Text en
spellingShingle Research Article
Ko, Gwangpyo
First, Melvin W
Burge, Harriet A
The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title_full The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title_fullStr The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title_full_unstemmed The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title_short The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
title_sort characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1240698/
https://www.ncbi.nlm.nih.gov/pubmed/11781170
work_keys_str_mv AT kogwangpyo thecharacterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms
AT firstmelvinw thecharacterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms
AT burgeharrieta thecharacterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms
AT kogwangpyo characterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms
AT firstmelvinw characterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms
AT burgeharrieta characterizationofupperroomultravioletgermicidalirradiationininactivatingairbornemicroorganisms