Cargando…

Volatile organic compounds as breath biomarkers for active and passive smoking.

We used real-time breath measurement technology to investigate the suitability of some volatile organic compounds (VOCs) as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to tobacco smoke. Experiments were cond...

Descripción completa

Detalles Bibliográficos
Autores principales: Gordon, Sydney M, Wallace, Lance A, Brinkman, Marielle C, Callahan, Patrick J, Kenny, Donald V
Formato: Texto
Lenguaje:English
Publicado: 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1240915/
https://www.ncbi.nlm.nih.gov/pubmed/12117646
_version_ 1782125268773634048
author Gordon, Sydney M
Wallace, Lance A
Brinkman, Marielle C
Callahan, Patrick J
Kenny, Donald V
author_facet Gordon, Sydney M
Wallace, Lance A
Brinkman, Marielle C
Callahan, Patrick J
Kenny, Donald V
author_sort Gordon, Sydney M
collection PubMed
description We used real-time breath measurement technology to investigate the suitability of some volatile organic compounds (VOCs) as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to tobacco smoke. Experiments were conducted with five smoker/nonsmoker pairs. The target VOCs included benzene, 1,3-butadiene, and the cigarette smoke biomarker 2,5-dimethylfuran. This study includes what we believe to be the first measurements of 1,3-butadiene in smokers' and nonsmokers' breath. The 1,3-butadiene and 2,5-dimethylfuran peak levels in the smokers' breath were similar (360 and 376 microg/m(3), respectively); the average benzene peak level was 522 microg/m(3). We found higher peak values of the target chemicals and shorter residence times in the body than previously reported, probably because of the improved time resolution made possible by the continuous breath measurement method. The real-time breath analyzer also showed the presence of the chemicals after exposure in the breath of the nonsmokers, but at greatly reduced levels. Single breath samples collected in evacuated canisters and analyzed independently with gas chromatography/mass spectrometry confirmed the presence of the target compounds in the postexposure breath of the nonsmokers but indicated that there was some contamination of the breath analyzer measurements. This was likely caused by desorption of organics from condensed tar in the analyzer tubing and on the quartz fiber filter used to remove particles. We used the decay data from the smokers to estimate residence times for the target chemicals. A two-compartment exponential model generally gave a better fit to the experimental decay data from the smokers than a single-compartment model. Residence times for benzene, 1,3-butadiene, and 2,5-dimethylfuran ranged from 0.5 (1,3-butadiene) to 0.9 min (benzene) for tau1 and were essentially constant (14 min) for tau2. These findings will be useful in models of environmental tobacco smoke exposure and risk.
format Text
id pubmed-1240915
institution National Center for Biotechnology Information
language English
publishDate 2002
record_format MEDLINE/PubMed
spelling pubmed-12409152005-11-08 Volatile organic compounds as breath biomarkers for active and passive smoking. Gordon, Sydney M Wallace, Lance A Brinkman, Marielle C Callahan, Patrick J Kenny, Donald V Environ Health Perspect Research Article We used real-time breath measurement technology to investigate the suitability of some volatile organic compounds (VOCs) as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to tobacco smoke. Experiments were conducted with five smoker/nonsmoker pairs. The target VOCs included benzene, 1,3-butadiene, and the cigarette smoke biomarker 2,5-dimethylfuran. This study includes what we believe to be the first measurements of 1,3-butadiene in smokers' and nonsmokers' breath. The 1,3-butadiene and 2,5-dimethylfuran peak levels in the smokers' breath were similar (360 and 376 microg/m(3), respectively); the average benzene peak level was 522 microg/m(3). We found higher peak values of the target chemicals and shorter residence times in the body than previously reported, probably because of the improved time resolution made possible by the continuous breath measurement method. The real-time breath analyzer also showed the presence of the chemicals after exposure in the breath of the nonsmokers, but at greatly reduced levels. Single breath samples collected in evacuated canisters and analyzed independently with gas chromatography/mass spectrometry confirmed the presence of the target compounds in the postexposure breath of the nonsmokers but indicated that there was some contamination of the breath analyzer measurements. This was likely caused by desorption of organics from condensed tar in the analyzer tubing and on the quartz fiber filter used to remove particles. We used the decay data from the smokers to estimate residence times for the target chemicals. A two-compartment exponential model generally gave a better fit to the experimental decay data from the smokers than a single-compartment model. Residence times for benzene, 1,3-butadiene, and 2,5-dimethylfuran ranged from 0.5 (1,3-butadiene) to 0.9 min (benzene) for tau1 and were essentially constant (14 min) for tau2. These findings will be useful in models of environmental tobacco smoke exposure and risk. 2002-07 /pmc/articles/PMC1240915/ /pubmed/12117646 Text en
spellingShingle Research Article
Gordon, Sydney M
Wallace, Lance A
Brinkman, Marielle C
Callahan, Patrick J
Kenny, Donald V
Volatile organic compounds as breath biomarkers for active and passive smoking.
title Volatile organic compounds as breath biomarkers for active and passive smoking.
title_full Volatile organic compounds as breath biomarkers for active and passive smoking.
title_fullStr Volatile organic compounds as breath biomarkers for active and passive smoking.
title_full_unstemmed Volatile organic compounds as breath biomarkers for active and passive smoking.
title_short Volatile organic compounds as breath biomarkers for active and passive smoking.
title_sort volatile organic compounds as breath biomarkers for active and passive smoking.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1240915/
https://www.ncbi.nlm.nih.gov/pubmed/12117646
work_keys_str_mv AT gordonsydneym volatileorganiccompoundsasbreathbiomarkersforactiveandpassivesmoking
AT wallacelancea volatileorganiccompoundsasbreathbiomarkersforactiveandpassivesmoking
AT brinkmanmariellec volatileorganiccompoundsasbreathbiomarkersforactiveandpassivesmoking
AT callahanpatrickj volatileorganiccompoundsasbreathbiomarkersforactiveandpassivesmoking
AT kennydonaldv volatileorganiccompoundsasbreathbiomarkersforactiveandpassivesmoking