Cargando…

Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria

A previously healthy man working as a machine operator in an automotive factory developed respiratory symptoms. Medical evaluation showed abnormal pulmonary function tests, a lung biopsy showed hypersensitivity pneumonitis, and his illness was traced to his work environment. His physician asked the...

Descripción completa

Detalles Bibliográficos
Autores principales: Beckett, William, Kallay, Michael, Sood, Akshay, Zuo, Zhengfa, Milton, Donald
Formato: Texto
Lenguaje:English
Publicado: National Institue of Environmental Health Sciences 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1257604/
https://www.ncbi.nlm.nih.gov/pubmed/15929902
http://dx.doi.org/10.1289/ehp.7727
_version_ 1782125831494041600
author Beckett, William
Kallay, Michael
Sood, Akshay
Zuo, Zhengfa
Milton, Donald
author_facet Beckett, William
Kallay, Michael
Sood, Akshay
Zuo, Zhengfa
Milton, Donald
author_sort Beckett, William
collection PubMed
description A previously healthy man working as a machine operator in an automotive factory developed respiratory symptoms. Medical evaluation showed abnormal pulmonary function tests, a lung biopsy showed hypersensitivity pneumonitis, and his illness was traced to his work environment. His physician asked the employer to remove him from exposure to metalworking fluids. Symptoms reoccurred when he was later reexposed to metalworking fluids, and further permanent decrement in his lung function occurred. Investigation of his workplace showed that five of six large reservoirs of metalworking fluids (cutting oils) grew Mycobacterium chelonae (or Mycobacterium immunogenum), an organism previously associated with outbreaks of hypersensitivity pneumonitis in automaking factories. His lung function remained stable after complete removal from exposure. The employer, metalworking fluid supplier, union, and the National Institute for Occupational Safety and Health were notified of this sentinel health event. No further cases have been documented in this workplace.
format Text
id pubmed-1257604
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher National Institue of Environmental Health Sciences
record_format MEDLINE/PubMed
spelling pubmed-12576042005-11-08 Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria Beckett, William Kallay, Michael Sood, Akshay Zuo, Zhengfa Milton, Donald Environ Health Perspect Environmental Medicine A previously healthy man working as a machine operator in an automotive factory developed respiratory symptoms. Medical evaluation showed abnormal pulmonary function tests, a lung biopsy showed hypersensitivity pneumonitis, and his illness was traced to his work environment. His physician asked the employer to remove him from exposure to metalworking fluids. Symptoms reoccurred when he was later reexposed to metalworking fluids, and further permanent decrement in his lung function occurred. Investigation of his workplace showed that five of six large reservoirs of metalworking fluids (cutting oils) grew Mycobacterium chelonae (or Mycobacterium immunogenum), an organism previously associated with outbreaks of hypersensitivity pneumonitis in automaking factories. His lung function remained stable after complete removal from exposure. The employer, metalworking fluid supplier, union, and the National Institute for Occupational Safety and Health were notified of this sentinel health event. No further cases have been documented in this workplace. National Institue of Environmental Health Sciences 2005-06 2005-02-10 /pmc/articles/PMC1257604/ /pubmed/15929902 http://dx.doi.org/10.1289/ehp.7727 Text en http://creativecommons.org/publicdomain/mark/1.0/ Publication of EHP lies in the public domain and is therefore without copyright. All text from EHP may be reprinted freely. Use of materials published in EHP should be acknowledged (for example, ?Reproduced with permission from Environmental Health Perspectives?); pertinent reference information should be provided for the article from which the material was reproduced. Articles from EHP, especially the News section, may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Environmental Medicine
Beckett, William
Kallay, Michael
Sood, Akshay
Zuo, Zhengfa
Milton, Donald
Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title_full Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title_fullStr Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title_full_unstemmed Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title_short Hypersensitivity Pneumonitis Associated with Environmental Mycobacteria
title_sort hypersensitivity pneumonitis associated with environmental mycobacteria
topic Environmental Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1257604/
https://www.ncbi.nlm.nih.gov/pubmed/15929902
http://dx.doi.org/10.1289/ehp.7727
work_keys_str_mv AT beckettwilliam hypersensitivitypneumonitisassociatedwithenvironmentalmycobacteria
AT kallaymichael hypersensitivitypneumonitisassociatedwithenvironmentalmycobacteria
AT soodakshay hypersensitivitypneumonitisassociatedwithenvironmentalmycobacteria
AT zuozhengfa hypersensitivitypneumonitisassociatedwithenvironmentalmycobacteria
AT miltondonald hypersensitivitypneumonitisassociatedwithenvironmentalmycobacteria