Cargando…

Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature

BACKGROUND: There are no studies that have directly investigated the incremental reduction in sensory morbidity that lymphoscintigraphy images (LS) and triangulated body marking or other skin marking techniques provide during sentinel lymph node biopsy (SLNB) compared to using only the probe without...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Suk Chul, Kim, Dong Wook, Moadel, Renee M, Kim, Chun K, Chatterjee, Samprit, Shafir, Michail K, Travis, Arlene, Machac, Josef, Krynyckyi, Borys R
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1262786/
https://www.ncbi.nlm.nih.gov/pubmed/16194276
http://dx.doi.org/10.1186/1477-7819-3-64
_version_ 1782125915078131712
author Kim, Suk Chul
Kim, Dong Wook
Moadel, Renee M
Kim, Chun K
Chatterjee, Samprit
Shafir, Michail K
Travis, Arlene
Machac, Josef
Krynyckyi, Borys R
author_facet Kim, Suk Chul
Kim, Dong Wook
Moadel, Renee M
Kim, Chun K
Chatterjee, Samprit
Shafir, Michail K
Travis, Arlene
Machac, Josef
Krynyckyi, Borys R
author_sort Kim, Suk Chul
collection PubMed
description BACKGROUND: There are no studies that have directly investigated the incremental reduction in sensory morbidity that lymphoscintigraphy images (LS) and triangulated body marking or other skin marking techniques provide during sentinel lymph node biopsy (SLNB) compared to using only the probe without LS and skin marking or using only dye. However, an indirect assessment of this potential for additional sensory morbidity reduction is possible by extracting morbidity data from studies comparing the morbidity of SLNB to that of axillary lymph node dissection. METHODS: A literature search yielded 13 articles that had data on sensory morbidity at specific time points on pain, numbness or paresthesia from SLNB that used radiotracer and probe or used only dye as a primary method of finding the sentinel node (SN). Of these, 10 utilized LS, while 3 did not utilize LS. By matching the data in studies not employing LS to the studies that did, comparisons regarding the percentage of patients experiencing pain, numbness/paresthesia after SLNB could be reasonably attempted at a cutoff of 9 months. RESULTS: In the 7 studies reporting on pain after 9 months (> 9 months) that used LS (1347 patients), 13.8% of patients reported these symptoms, while in the one study that did not use LS (143 patients), 28.7% of patients reported these symptoms at > 9 months (P < 0.0001). In the 6 studies reporting on numbness and/or paresthesia at > 9 months that used LS (601 patients), 12.5% of patients reported these symptoms, while in the 3 studies that did not use LS (229 patients), 23.1% of patients reported these symptoms at > 9 months (P = 0.0002). Similar trends were also noted for all these symptoms at ≤ 9 months. CONCLUSION: Because of variations in techniques and time of assessing morbidity, direct comparisons between studies are difficult. Nevertheless at a minimum, a clear trend is present: having the LS images and skin markings to assist during SLNB appears to yield more favorable morbidity outcomes for the patients compared to performing SLNB with only the probe or performing SLNB with dye alone. These results are extremely pertinent, as the main reason for performing SLNB itself in the first place is to achieve reduced morbidity.
format Text
id pubmed-1262786
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-12627862005-10-23 Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature Kim, Suk Chul Kim, Dong Wook Moadel, Renee M Kim, Chun K Chatterjee, Samprit Shafir, Michail K Travis, Arlene Machac, Josef Krynyckyi, Borys R World J Surg Oncol Research BACKGROUND: There are no studies that have directly investigated the incremental reduction in sensory morbidity that lymphoscintigraphy images (LS) and triangulated body marking or other skin marking techniques provide during sentinel lymph node biopsy (SLNB) compared to using only the probe without LS and skin marking or using only dye. However, an indirect assessment of this potential for additional sensory morbidity reduction is possible by extracting morbidity data from studies comparing the morbidity of SLNB to that of axillary lymph node dissection. METHODS: A literature search yielded 13 articles that had data on sensory morbidity at specific time points on pain, numbness or paresthesia from SLNB that used radiotracer and probe or used only dye as a primary method of finding the sentinel node (SN). Of these, 10 utilized LS, while 3 did not utilize LS. By matching the data in studies not employing LS to the studies that did, comparisons regarding the percentage of patients experiencing pain, numbness/paresthesia after SLNB could be reasonably attempted at a cutoff of 9 months. RESULTS: In the 7 studies reporting on pain after 9 months (> 9 months) that used LS (1347 patients), 13.8% of patients reported these symptoms, while in the one study that did not use LS (143 patients), 28.7% of patients reported these symptoms at > 9 months (P < 0.0001). In the 6 studies reporting on numbness and/or paresthesia at > 9 months that used LS (601 patients), 12.5% of patients reported these symptoms, while in the 3 studies that did not use LS (229 patients), 23.1% of patients reported these symptoms at > 9 months (P = 0.0002). Similar trends were also noted for all these symptoms at ≤ 9 months. CONCLUSION: Because of variations in techniques and time of assessing morbidity, direct comparisons between studies are difficult. Nevertheless at a minimum, a clear trend is present: having the LS images and skin markings to assist during SLNB appears to yield more favorable morbidity outcomes for the patients compared to performing SLNB with only the probe or performing SLNB with dye alone. These results are extremely pertinent, as the main reason for performing SLNB itself in the first place is to achieve reduced morbidity. BioMed Central 2005-09-29 /pmc/articles/PMC1262786/ /pubmed/16194276 http://dx.doi.org/10.1186/1477-7819-3-64 Text en Copyright © 2005 Kim et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Kim, Suk Chul
Kim, Dong Wook
Moadel, Renee M
Kim, Chun K
Chatterjee, Samprit
Shafir, Michail K
Travis, Arlene
Machac, Josef
Krynyckyi, Borys R
Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title_full Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title_fullStr Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title_full_unstemmed Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title_short Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature
title_sort using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: a review of the literature
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1262786/
https://www.ncbi.nlm.nih.gov/pubmed/16194276
http://dx.doi.org/10.1186/1477-7819-3-64
work_keys_str_mv AT kimsukchul usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT kimdongwook usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT moadelreneem usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT kimchunk usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT chatterjeesamprit usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT shafirmichailk usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT travisarlene usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT machacjosef usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature
AT krynyckyiborysr usingtheintraoperativehandheldprobewithoutlymphoscintigraphyorusingonlydyecorrelateswithhighersensorymorbidityfollowingsentinellymphnodebiopsyinbreastcancerareviewoftheliterature