Cargando…

Reliability of the biceps brachii M-wave

BACKGROUND: The peak-to-peak (P-P) amplitude of the maximum M-wave and the area of the negative phase of the curve are important measures that serve as methodological controls in H-reflex studies, motor unit number estimation (MUNE) procedures, and normalization factors for voluntary electromyograph...

Descripción completa

Detalles Bibliográficos
Autores principales: Calder, Kristina M, Hall, Lesley-Ann, Lester, Steve M, Inglis, J Greig, Gabriel, David A
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1334194/
https://www.ncbi.nlm.nih.gov/pubmed/16332261
http://dx.doi.org/10.1186/1743-0003-2-33
_version_ 1782126561429815296
author Calder, Kristina M
Hall, Lesley-Ann
Lester, Steve M
Inglis, J Greig
Gabriel, David A
author_facet Calder, Kristina M
Hall, Lesley-Ann
Lester, Steve M
Inglis, J Greig
Gabriel, David A
author_sort Calder, Kristina M
collection PubMed
description BACKGROUND: The peak-to-peak (P-P) amplitude of the maximum M-wave and the area of the negative phase of the curve are important measures that serve as methodological controls in H-reflex studies, motor unit number estimation (MUNE) procedures, and normalization factors for voluntary electromyographic (EMG) activity. These methodologies assume, with little evidence, that M-wave variability is minimal. This study therefore examined the intraclass reliability of these measures for the biceps brachii. METHODS: Twenty-two healthy adults (4 males and 18 females) participated in 5 separate days of electrical stimulation of the musculocutaneous nerve supplying the biceps brachii muscle. A total of 10 stimulations were recorded on each of the 5 test sessions: a total of fifty trials were used for analysis. A two-factor repeated measures analysis of variance (ANOVA) evaluated the stability of the group means across test sessions. The consistency of scores within individuals was determined by calculating the intraclass correlation coefficient (ICC). The variance ratio (VR) was then used to assess the reproducibility of the shape of the maximum M-wave within individual subjects. RESULTS: The P-P amplitude means ranged from 12.62 ± 4.33 mV to 13.45 ± 4.07 mV across test sessions. The group means were highly stable. ICC analysis also revealed that the scores were very consistent (ICC = 0.98). The group means for the area of the negative phase of the maximum M-wave were also stable (117 to 126 mV·ms). The ICC analysis also indicated a high degree of consistency (ICC = 0.96). The VR for the sample was 0.244 ± 0.169, which suggests that the biceps brachii maximum M-wave shape was in general very reproducible for each subject. CONCLUSION: The results support the use of P-P amplitude of the maximum M-wave as a methodological control in H-reflex studies, and as a normalization factor for voluntary EMG. The area of the negative phase of the maximum M-wave is both stable and consistent, and the shape of the entire waveform is highly reproducible and may be used for MUNE procedures.
format Text
id pubmed-1334194
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-13341942006-01-19 Reliability of the biceps brachii M-wave Calder, Kristina M Hall, Lesley-Ann Lester, Steve M Inglis, J Greig Gabriel, David A J Neuroengineering Rehabil Research BACKGROUND: The peak-to-peak (P-P) amplitude of the maximum M-wave and the area of the negative phase of the curve are important measures that serve as methodological controls in H-reflex studies, motor unit number estimation (MUNE) procedures, and normalization factors for voluntary electromyographic (EMG) activity. These methodologies assume, with little evidence, that M-wave variability is minimal. This study therefore examined the intraclass reliability of these measures for the biceps brachii. METHODS: Twenty-two healthy adults (4 males and 18 females) participated in 5 separate days of electrical stimulation of the musculocutaneous nerve supplying the biceps brachii muscle. A total of 10 stimulations were recorded on each of the 5 test sessions: a total of fifty trials were used for analysis. A two-factor repeated measures analysis of variance (ANOVA) evaluated the stability of the group means across test sessions. The consistency of scores within individuals was determined by calculating the intraclass correlation coefficient (ICC). The variance ratio (VR) was then used to assess the reproducibility of the shape of the maximum M-wave within individual subjects. RESULTS: The P-P amplitude means ranged from 12.62 ± 4.33 mV to 13.45 ± 4.07 mV across test sessions. The group means were highly stable. ICC analysis also revealed that the scores were very consistent (ICC = 0.98). The group means for the area of the negative phase of the maximum M-wave were also stable (117 to 126 mV·ms). The ICC analysis also indicated a high degree of consistency (ICC = 0.96). The VR for the sample was 0.244 ± 0.169, which suggests that the biceps brachii maximum M-wave shape was in general very reproducible for each subject. CONCLUSION: The results support the use of P-P amplitude of the maximum M-wave as a methodological control in H-reflex studies, and as a normalization factor for voluntary EMG. The area of the negative phase of the maximum M-wave is both stable and consistent, and the shape of the entire waveform is highly reproducible and may be used for MUNE procedures. BioMed Central 2005-12-06 /pmc/articles/PMC1334194/ /pubmed/16332261 http://dx.doi.org/10.1186/1743-0003-2-33 Text en Copyright © 2005 Calder et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Calder, Kristina M
Hall, Lesley-Ann
Lester, Steve M
Inglis, J Greig
Gabriel, David A
Reliability of the biceps brachii M-wave
title Reliability of the biceps brachii M-wave
title_full Reliability of the biceps brachii M-wave
title_fullStr Reliability of the biceps brachii M-wave
title_full_unstemmed Reliability of the biceps brachii M-wave
title_short Reliability of the biceps brachii M-wave
title_sort reliability of the biceps brachii m-wave
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1334194/
https://www.ncbi.nlm.nih.gov/pubmed/16332261
http://dx.doi.org/10.1186/1743-0003-2-33
work_keys_str_mv AT calderkristinam reliabilityofthebicepsbrachiimwave
AT halllesleyann reliabilityofthebicepsbrachiimwave
AT lesterstevem reliabilityofthebicepsbrachiimwave
AT inglisjgreig reliabilityofthebicepsbrachiimwave
AT gabrieldavida reliabilityofthebicepsbrachiimwave