Cargando…

Systemic coagulation parameters in mice after treatment with vascular targeting agents

BACKGROUND: Vascular targeting of malignant tumors has become a clinically validated new treatment approach with clear patient benefit. However clinical studies have also revealed that some types of vascular targeting agents (VTAs) are prone to coagulation system side effects. It is therefore essent...

Descripción completa

Detalles Bibliográficos
Autores principales: Unruh, Maike, Grunow, Andrea, Gottstein, Claudia
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1343590/
https://www.ncbi.nlm.nih.gov/pubmed/16336690
http://dx.doi.org/10.1186/1477-9560-3-21
_version_ 1782126589396385792
author Unruh, Maike
Grunow, Andrea
Gottstein, Claudia
author_facet Unruh, Maike
Grunow, Andrea
Gottstein, Claudia
author_sort Unruh, Maike
collection PubMed
description BACKGROUND: Vascular targeting of malignant tumors has become a clinically validated new treatment approach with clear patient benefit. However clinical studies have also revealed that some types of vascular targeting agents (VTAs) are prone to coagulation system side effects. It is therefore essential to predetermine coagulation parameters in preclinical studies. As of to date, this has rarely been done, predominantly due to technical issues. The goal of this study was to establish and apply a standardized process, whereby systemic coagulation activation can be routinely measured in mice. RESULTS: We have evaluated a number of sampling techniques and coagulation tests regarding their suitability for this purpose. We were able to adapt two assays measuring soluble fibrin, a marker for a prethrombotic status. Thus, soluble fibrin could be measured for the first time in mice. All assays were validated in a positive control model for systemic coagulation activation, i.e. lipopolysaccharide-induced endotoxemia. Based on our results, we selected a panel of coagulation tests, which are both feasable and informative for preclinical testing of VTAs: soluble fibrin, thrombin-antithrombin complexes, free antithrombin III, white blood cell counts and platelet counts. The effect of tumor transplants on coagulation parameters was evaluated using this panel. We then applied this set of assays in treatment studies with a VTA developed in our laboratory to investigate a potential systemic coagulation activation. CONCLUSION: We have established a standardized panel of assays that can be used to test murine blood samples for coagulation activation in preclinical studies. All tests are feasible to perform in any research laboratory without specialized equipment. In addition, this is the first report to measure soluble fibrin, an early marker of systemic coagulation activation, in mice. The panel was applied on tumor bearing mice and mice treated with a VTA. We suggest its general application for coagulation activation analyses in mice.
format Text
id pubmed-1343590
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-13435902006-01-22 Systemic coagulation parameters in mice after treatment with vascular targeting agents Unruh, Maike Grunow, Andrea Gottstein, Claudia Thromb J Original Basic Research BACKGROUND: Vascular targeting of malignant tumors has become a clinically validated new treatment approach with clear patient benefit. However clinical studies have also revealed that some types of vascular targeting agents (VTAs) are prone to coagulation system side effects. It is therefore essential to predetermine coagulation parameters in preclinical studies. As of to date, this has rarely been done, predominantly due to technical issues. The goal of this study was to establish and apply a standardized process, whereby systemic coagulation activation can be routinely measured in mice. RESULTS: We have evaluated a number of sampling techniques and coagulation tests regarding their suitability for this purpose. We were able to adapt two assays measuring soluble fibrin, a marker for a prethrombotic status. Thus, soluble fibrin could be measured for the first time in mice. All assays were validated in a positive control model for systemic coagulation activation, i.e. lipopolysaccharide-induced endotoxemia. Based on our results, we selected a panel of coagulation tests, which are both feasable and informative for preclinical testing of VTAs: soluble fibrin, thrombin-antithrombin complexes, free antithrombin III, white blood cell counts and platelet counts. The effect of tumor transplants on coagulation parameters was evaluated using this panel. We then applied this set of assays in treatment studies with a VTA developed in our laboratory to investigate a potential systemic coagulation activation. CONCLUSION: We have established a standardized panel of assays that can be used to test murine blood samples for coagulation activation in preclinical studies. All tests are feasible to perform in any research laboratory without specialized equipment. In addition, this is the first report to measure soluble fibrin, an early marker of systemic coagulation activation, in mice. The panel was applied on tumor bearing mice and mice treated with a VTA. We suggest its general application for coagulation activation analyses in mice. BioMed Central 2005-12-10 /pmc/articles/PMC1343590/ /pubmed/16336690 http://dx.doi.org/10.1186/1477-9560-3-21 Text en Copyright © 2005 Unruh et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Basic Research
Unruh, Maike
Grunow, Andrea
Gottstein, Claudia
Systemic coagulation parameters in mice after treatment with vascular targeting agents
title Systemic coagulation parameters in mice after treatment with vascular targeting agents
title_full Systemic coagulation parameters in mice after treatment with vascular targeting agents
title_fullStr Systemic coagulation parameters in mice after treatment with vascular targeting agents
title_full_unstemmed Systemic coagulation parameters in mice after treatment with vascular targeting agents
title_short Systemic coagulation parameters in mice after treatment with vascular targeting agents
title_sort systemic coagulation parameters in mice after treatment with vascular targeting agents
topic Original Basic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1343590/
https://www.ncbi.nlm.nih.gov/pubmed/16336690
http://dx.doi.org/10.1186/1477-9560-3-21
work_keys_str_mv AT unruhmaike systemiccoagulationparametersinmiceaftertreatmentwithvasculartargetingagents
AT grunowandrea systemiccoagulationparametersinmiceaftertreatmentwithvasculartargetingagents
AT gottsteinclaudia systemiccoagulationparametersinmiceaftertreatmentwithvasculartargetingagents