High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection

BACKGROUND: The taxanes paclitaxel and docetaxel have traditionally been used in high doses every third week in the treatment of cancer. Lately there has been a trend towards giving weekly low doses to improve the therapeutic index. This article describes the development of high performance liquid c...

Descripción completa

Detalles Bibliográficos
Autores principales: Andersen, Anders, Warren, David J, Brunsvig, Paal F, Aamdal, Steinar, Kristensen, Gunnar B, Olsen, Harald
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1382254/
https://www.ncbi.nlm.nih.gov/pubmed/16412237
http://dx.doi.org/10.1186/1472-6904-6-2
_version_ 1782126855863664640
author Andersen, Anders
Warren, David J
Brunsvig, Paal F
Aamdal, Steinar
Kristensen, Gunnar B
Olsen, Harald
author_facet Andersen, Anders
Warren, David J
Brunsvig, Paal F
Aamdal, Steinar
Kristensen, Gunnar B
Olsen, Harald
author_sort Andersen, Anders
collection PubMed
description BACKGROUND: The taxanes paclitaxel and docetaxel have traditionally been used in high doses every third week in the treatment of cancer. Lately there has been a trend towards giving weekly low doses to improve the therapeutic index. This article describes the development of high performance liquid chromatographic (HPLC) methods suitable for monitoring taxane levels in patients, focusing on patients receiving low-dose therapy. METHODS: Paclitaxel and docetaxel were extracted from human plasma by solid phase extraction, and detected by absorbance at 227 nm after separation by reversed phase high performance liquid chromatography. The methods were validated and their performance were tested using samples from patients receiving paclitaxel or docetaxel. RESULTS: The limits of quantitation were 1 nM for docetaxel and 1.2 nM for paclitaxel. For both compounds linearity was confirmed from the limit of quantitation up to 1000 nM in plasma. The recoveries ranged between 92% and 118% for docetaxel and between 76% and 104% for paclitaxel. Accuracy and precision were within international acceptance criteria, that is within ± 15%, except at the limit of quantitation where values within ± 20% are acceptable. Low-dose patients included in an on going clinical trial had a median docetaxel concentration of 2.8 nM at 72 hours post infusion. Patients receiving 100 mg/m(2 )of paclitaxel had a mean paclitaxel concentration of 21 nM 48 hours after the end of infusion. CONCLUSION: We have developed an HPLC method using UV detection capable of quantifying 1 nM of docetaxel in plasma samples. The method should be useful for pharmacokinetic determinations at all relevant doses of docetaxel. Using a similar methodology paclitaxel can be quantified down to a concentration of 1.2 nM in plasma with acceptable accuracy and precision. We further demonstrate that the previously reported negative influence of Cremophor EL on assay performance may be overcome by degradation of the detergent by incubation with lipase.
format Text
id pubmed-1382254
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-13822542006-02-25 High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection Andersen, Anders Warren, David J Brunsvig, Paal F Aamdal, Steinar Kristensen, Gunnar B Olsen, Harald BMC Clin Pharmacol Technical Advance BACKGROUND: The taxanes paclitaxel and docetaxel have traditionally been used in high doses every third week in the treatment of cancer. Lately there has been a trend towards giving weekly low doses to improve the therapeutic index. This article describes the development of high performance liquid chromatographic (HPLC) methods suitable for monitoring taxane levels in patients, focusing on patients receiving low-dose therapy. METHODS: Paclitaxel and docetaxel were extracted from human plasma by solid phase extraction, and detected by absorbance at 227 nm after separation by reversed phase high performance liquid chromatography. The methods were validated and their performance were tested using samples from patients receiving paclitaxel or docetaxel. RESULTS: The limits of quantitation were 1 nM for docetaxel and 1.2 nM for paclitaxel. For both compounds linearity was confirmed from the limit of quantitation up to 1000 nM in plasma. The recoveries ranged between 92% and 118% for docetaxel and between 76% and 104% for paclitaxel. Accuracy and precision were within international acceptance criteria, that is within ± 15%, except at the limit of quantitation where values within ± 20% are acceptable. Low-dose patients included in an on going clinical trial had a median docetaxel concentration of 2.8 nM at 72 hours post infusion. Patients receiving 100 mg/m(2 )of paclitaxel had a mean paclitaxel concentration of 21 nM 48 hours after the end of infusion. CONCLUSION: We have developed an HPLC method using UV detection capable of quantifying 1 nM of docetaxel in plasma samples. The method should be useful for pharmacokinetic determinations at all relevant doses of docetaxel. Using a similar methodology paclitaxel can be quantified down to a concentration of 1.2 nM in plasma with acceptable accuracy and precision. We further demonstrate that the previously reported negative influence of Cremophor EL on assay performance may be overcome by degradation of the detergent by incubation with lipase. BioMed Central 2006-01-13 /pmc/articles/PMC1382254/ /pubmed/16412237 http://dx.doi.org/10.1186/1472-6904-6-2 Text en Copyright © 2006 Andersen et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Andersen, Anders
Warren, David J
Brunsvig, Paal F
Aamdal, Steinar
Kristensen, Gunnar B
Olsen, Harald
High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title_full High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title_fullStr High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title_full_unstemmed High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title_short High sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with UV detection
title_sort high sensitivity assays for docetaxel and paclitaxel in plasma using solid-phase extraction and high-performance liquid chromatography with uv detection
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1382254/
https://www.ncbi.nlm.nih.gov/pubmed/16412237
http://dx.doi.org/10.1186/1472-6904-6-2
work_keys_str_mv AT andersenanders highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection
AT warrendavidj highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection
AT brunsvigpaalf highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection
AT aamdalsteinar highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection
AT kristensengunnarb highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection
AT olsenharald highsensitivityassaysfordocetaxelandpaclitaxelinplasmausingsolidphaseextractionandhighperformanceliquidchromatographywithuvdetection