Cargando…

Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid

Cerebrospinal fluid (CSF) potentially carries an archive of peptides and small proteins relevant to pathological processes in the central nervous system (CNS) and surrounding brain tissue. Proteomics is especially well suited for the discovery of biomarkers of diagnostic potential in CSF for early d...

Descripción completa

Detalles Bibliográficos
Autores principales: Guerreiro, Nelson, Gomez-Mancilla, Baltazar, Charmont, Stéphane
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1464122/
https://www.ncbi.nlm.nih.gov/pubmed/16643650
http://dx.doi.org/10.1186/1477-5956-4-7
_version_ 1782127537744248832
author Guerreiro, Nelson
Gomez-Mancilla, Baltazar
Charmont, Stéphane
author_facet Guerreiro, Nelson
Gomez-Mancilla, Baltazar
Charmont, Stéphane
author_sort Guerreiro, Nelson
collection PubMed
description Cerebrospinal fluid (CSF) potentially carries an archive of peptides and small proteins relevant to pathological processes in the central nervous system (CNS) and surrounding brain tissue. Proteomics is especially well suited for the discovery of biomarkers of diagnostic potential in CSF for early diagnosis and discrimination of several neurodegenerative diseases. ProteinChip surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) is one such approach which offers a unique platform for high throughput profiling of peptides and small proteins in CSF. In this study, we evaluated methodologies for the retention of CSF proteins < 20 kDa in size, and identify a strategy for screening small proteins and peptides in CSF. ProteinChip array types, along with sample and binding buffer conditions, and matrices were investigated. By coupling the processing of arrays to a liquid handler reproducible and reliable profiles, with mean peak coefficients of variation < 20%, were achieved for intra- and inter-assays under selected conditions. Based on peak m/z we found a high degree of overlap between the tested array surfaces. The combination of CM10 and IMAC30 arrays was sufficient to represent between 80–90% of all assigned peaks when using either sinapinic acid or α-Cyano-4-hydroxycinnamic acid as the energy absorbing matrices. Moreover, arrays processed with SPA consistently showed better peak resolution and higher peak number across all surfaces within the measured mass range. We intend to use CM10 and IMAC30 arrays prepared in sinapinic acid as a fast and cost-effective approach to drive decisions on sample selection prior to more in-depth discovery of diagnostic biomarkers in CSF using alternative but complementary proteomic strategies.
format Text
id pubmed-1464122
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-14641222006-05-23 Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid Guerreiro, Nelson Gomez-Mancilla, Baltazar Charmont, Stéphane Proteome Sci Methodology Cerebrospinal fluid (CSF) potentially carries an archive of peptides and small proteins relevant to pathological processes in the central nervous system (CNS) and surrounding brain tissue. Proteomics is especially well suited for the discovery of biomarkers of diagnostic potential in CSF for early diagnosis and discrimination of several neurodegenerative diseases. ProteinChip surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) is one such approach which offers a unique platform for high throughput profiling of peptides and small proteins in CSF. In this study, we evaluated methodologies for the retention of CSF proteins < 20 kDa in size, and identify a strategy for screening small proteins and peptides in CSF. ProteinChip array types, along with sample and binding buffer conditions, and matrices were investigated. By coupling the processing of arrays to a liquid handler reproducible and reliable profiles, with mean peak coefficients of variation < 20%, were achieved for intra- and inter-assays under selected conditions. Based on peak m/z we found a high degree of overlap between the tested array surfaces. The combination of CM10 and IMAC30 arrays was sufficient to represent between 80–90% of all assigned peaks when using either sinapinic acid or α-Cyano-4-hydroxycinnamic acid as the energy absorbing matrices. Moreover, arrays processed with SPA consistently showed better peak resolution and higher peak number across all surfaces within the measured mass range. We intend to use CM10 and IMAC30 arrays prepared in sinapinic acid as a fast and cost-effective approach to drive decisions on sample selection prior to more in-depth discovery of diagnostic biomarkers in CSF using alternative but complementary proteomic strategies. BioMed Central 2006-04-27 /pmc/articles/PMC1464122/ /pubmed/16643650 http://dx.doi.org/10.1186/1477-5956-4-7 Text en Copyright © 2006 Guerreiro et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Guerreiro, Nelson
Gomez-Mancilla, Baltazar
Charmont, Stéphane
Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title_full Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title_fullStr Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title_full_unstemmed Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title_short Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
title_sort optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1464122/
https://www.ncbi.nlm.nih.gov/pubmed/16643650
http://dx.doi.org/10.1186/1477-5956-4-7
work_keys_str_mv AT guerreironelson optimizationandevaluationofsurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryforproteinprofilingofcerebrospinalfluid
AT gomezmancillabaltazar optimizationandevaluationofsurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryforproteinprofilingofcerebrospinalfluid
AT charmontstephane optimizationandevaluationofsurfaceenhancedlaserdesorptionionizationtimeofflightmassspectrometryforproteinprofilingofcerebrospinalfluid