Cargando…

The photocurrent response of human cones is fast and monophasic

BACKGROUND: The precise form of the light response of human cone photoreceptors in vivo has not been established with certainty. To investigate the response shape we compare the predictions of a recent model of transduction in primate cone photoreceptors with measurements extracted from human cones...

Descripción completa

Detalles Bibliográficos
Autores principales: van Hateren, JH, Lamb, TD
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1464134/
https://www.ncbi.nlm.nih.gov/pubmed/16626487
http://dx.doi.org/10.1186/1471-2202-7-34
_version_ 1782127540668727296
author van Hateren, JH
Lamb, TD
author_facet van Hateren, JH
Lamb, TD
author_sort van Hateren, JH
collection PubMed
description BACKGROUND: The precise form of the light response of human cone photoreceptors in vivo has not been established with certainty. To investigate the response shape we compare the predictions of a recent model of transduction in primate cone photoreceptors with measurements extracted from human cones using the paired-flash electroretinogram method. As a check, we also compare the predictions with previous single-cell measurements of ground squirrel cone responses. RESULTS: The predictions of the model provide a good description of the measurements, using values of parameters within the range previously determined for primate retina. The dim-flash response peaks in about 20 ms, and flash responses at all intensities are essentially monophasic. Three time constants in the model are extremely short: the two time constants for inactivation (of visual pigment and of transducin/phosphodiesterase) are around 3 and 10 ms, and the time constant for calcium equilibration lies in the same range. CONCLUSION: The close correspondence between experiment and theory, using parameters previously derived for recordings from macaque retina, supports the notion that the electroretinogram approach and the modelling approach both provide an accurate estimate of the cone photoresponse in the living human eye. For reasons that remain unclear, the responses of isolated photoreceptors from the macaque retina, recorded previously using the suction pipette method, are considerably slower than found here, and display biphasic kinetics.
format Text
id pubmed-1464134
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-14641342006-05-23 The photocurrent response of human cones is fast and monophasic van Hateren, JH Lamb, TD BMC Neurosci Research Article BACKGROUND: The precise form of the light response of human cone photoreceptors in vivo has not been established with certainty. To investigate the response shape we compare the predictions of a recent model of transduction in primate cone photoreceptors with measurements extracted from human cones using the paired-flash electroretinogram method. As a check, we also compare the predictions with previous single-cell measurements of ground squirrel cone responses. RESULTS: The predictions of the model provide a good description of the measurements, using values of parameters within the range previously determined for primate retina. The dim-flash response peaks in about 20 ms, and flash responses at all intensities are essentially monophasic. Three time constants in the model are extremely short: the two time constants for inactivation (of visual pigment and of transducin/phosphodiesterase) are around 3 and 10 ms, and the time constant for calcium equilibration lies in the same range. CONCLUSION: The close correspondence between experiment and theory, using parameters previously derived for recordings from macaque retina, supports the notion that the electroretinogram approach and the modelling approach both provide an accurate estimate of the cone photoresponse in the living human eye. For reasons that remain unclear, the responses of isolated photoreceptors from the macaque retina, recorded previously using the suction pipette method, are considerably slower than found here, and display biphasic kinetics. BioMed Central 2006-04-20 /pmc/articles/PMC1464134/ /pubmed/16626487 http://dx.doi.org/10.1186/1471-2202-7-34 Text en Copyright © 2006 van Hateren and Lamb; licensee BioMed Central Ltd.
spellingShingle Research Article
van Hateren, JH
Lamb, TD
The photocurrent response of human cones is fast and monophasic
title The photocurrent response of human cones is fast and monophasic
title_full The photocurrent response of human cones is fast and monophasic
title_fullStr The photocurrent response of human cones is fast and monophasic
title_full_unstemmed The photocurrent response of human cones is fast and monophasic
title_short The photocurrent response of human cones is fast and monophasic
title_sort photocurrent response of human cones is fast and monophasic
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1464134/
https://www.ncbi.nlm.nih.gov/pubmed/16626487
http://dx.doi.org/10.1186/1471-2202-7-34
work_keys_str_mv AT vanhaterenjh thephotocurrentresponseofhumanconesisfastandmonophasic
AT lambtd thephotocurrentresponseofhumanconesisfastandmonophasic
AT vanhaterenjh photocurrentresponseofhumanconesisfastandmonophasic
AT lambtd photocurrentresponseofhumanconesisfastandmonophasic