Cargando…

Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.

The transfer and distribution of paramagnetic manganese was investigated in the dually perfused human placenta in vitro (using 10, 20, 100 microM Mn with and without 54Mn) using magnetic resonance imaging (MRI) and conventional radiochemical techniques. The human placenta concentrated 54Mn rapidly d...

Descripción completa

Detalles Bibliográficos
Autores principales: Miller, R K, Mattison, D R, Panigel, M, Ceckler, T, Bryant, R, Thomford, P
Formato: Texto
Lenguaje:English
Publicado: 1987
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1474511/
https://www.ncbi.nlm.nih.gov/pubmed/3691434
_version_ 1782127926193422336
author Miller, R K
Mattison, D R
Panigel, M
Ceckler, T
Bryant, R
Thomford, P
author_facet Miller, R K
Mattison, D R
Panigel, M
Ceckler, T
Bryant, R
Thomford, P
author_sort Miller, R K
collection PubMed
description The transfer and distribution of paramagnetic manganese was investigated in the dually perfused human placenta in vitro (using 10, 20, 100 microM Mn with and without 54Mn) using magnetic resonance imaging (MRI) and conventional radiochemical techniques. The human placenta concentrated 54Mn rapidly during the first 15 min of perfusion and by 4 hr was four times greater than the concentrations of Mn in the maternal perfusate, while the concentration of Mn in the fetal perfusate was 25% of the maternal perfusate levels. Within placentae, 45% of the 54Mn was free in the 100,000g supernatant, with 45% in the 1,000g pellet. The magnetic field dependence of proton nuclear spin-lattice relaxation time (T1) in placental tissue supports this Mn binding. Mn primarily affected the MRI partial saturation rather than spin-echo images of the human placenta, which provided for the separation of perfusate contributions from those produced by Mn. The washout of the Mn from the placenta was slow compared with its uptake, as determined by MRI. Thus, Mn was concentrated by the human placenta, but transfer of Mn across the placenta was limited in either direction. These studies also illustrate the opportunity for studies of human placental function using magnetic resonance imaging as a noninvasive biomarker.
format Text
id pubmed-1474511
institution National Center for Biotechnology Information
language English
publishDate 1987
record_format MEDLINE/PubMed
spelling pubmed-14745112006-06-09 Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro. Miller, R K Mattison, D R Panigel, M Ceckler, T Bryant, R Thomford, P Environ Health Perspect Research Article The transfer and distribution of paramagnetic manganese was investigated in the dually perfused human placenta in vitro (using 10, 20, 100 microM Mn with and without 54Mn) using magnetic resonance imaging (MRI) and conventional radiochemical techniques. The human placenta concentrated 54Mn rapidly during the first 15 min of perfusion and by 4 hr was four times greater than the concentrations of Mn in the maternal perfusate, while the concentration of Mn in the fetal perfusate was 25% of the maternal perfusate levels. Within placentae, 45% of the 54Mn was free in the 100,000g supernatant, with 45% in the 1,000g pellet. The magnetic field dependence of proton nuclear spin-lattice relaxation time (T1) in placental tissue supports this Mn binding. Mn primarily affected the MRI partial saturation rather than spin-echo images of the human placenta, which provided for the separation of perfusate contributions from those produced by Mn. The washout of the Mn from the placenta was slow compared with its uptake, as determined by MRI. Thus, Mn was concentrated by the human placenta, but transfer of Mn across the placenta was limited in either direction. These studies also illustrate the opportunity for studies of human placental function using magnetic resonance imaging as a noninvasive biomarker. 1987-10 /pmc/articles/PMC1474511/ /pubmed/3691434 Text en
spellingShingle Research Article
Miller, R K
Mattison, D R
Panigel, M
Ceckler, T
Bryant, R
Thomford, P
Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title_full Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title_fullStr Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title_full_unstemmed Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title_short Kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
title_sort kinetic assessment of manganese using magnetic resonance imaging in the dually perfused human placenta in vitro.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1474511/
https://www.ncbi.nlm.nih.gov/pubmed/3691434
work_keys_str_mv AT millerrk kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro
AT mattisondr kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro
AT panigelm kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro
AT cecklert kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro
AT bryantr kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro
AT thomfordp kineticassessmentofmanganeseusingmagneticresonanceimagingintheduallyperfusedhumanplacentainvitro