Cargando…

Hemodynamic response to carbon monoxide.

Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize ti...

Descripción completa

Detalles Bibliográficos
Autor principal: Penney, D G
Formato: Texto
Lenguaje:English
Publicado: 1988
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1474537/
https://www.ncbi.nlm.nih.gov/pubmed/3289904
_version_ 1782127931831615488
author Penney, D G
author_facet Penney, D G
author_sort Penney, D G
collection PubMed
description Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. For example, tachycardia is commonly observed, although bradycardia also can result from myocardial and/or central nervous system (CNS) hypoxemia at high carboxyhemoglobin (COHb) saturations, as can electrocardiographic abnormalities. Augmented cardiac output usually observed with moderate COHb may be compromised in more severe poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.
format Text
id pubmed-1474537
institution National Center for Biotechnology Information
language English
publishDate 1988
record_format MEDLINE/PubMed
spelling pubmed-14745372006-06-09 Hemodynamic response to carbon monoxide. Penney, D G Environ Health Perspect Research Article Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. For example, tachycardia is commonly observed, although bradycardia also can result from myocardial and/or central nervous system (CNS) hypoxemia at high carboxyhemoglobin (COHb) saturations, as can electrocardiographic abnormalities. Augmented cardiac output usually observed with moderate COHb may be compromised in more severe poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date. 1988-04 /pmc/articles/PMC1474537/ /pubmed/3289904 Text en
spellingShingle Research Article
Penney, D G
Hemodynamic response to carbon monoxide.
title Hemodynamic response to carbon monoxide.
title_full Hemodynamic response to carbon monoxide.
title_fullStr Hemodynamic response to carbon monoxide.
title_full_unstemmed Hemodynamic response to carbon monoxide.
title_short Hemodynamic response to carbon monoxide.
title_sort hemodynamic response to carbon monoxide.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1474537/
https://www.ncbi.nlm.nih.gov/pubmed/3289904
work_keys_str_mv AT penneydg hemodynamicresponsetocarbonmonoxide