Cargando…

Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test

In the present study, we first report an in vivo characterization of flexor responses induced by three distinct sine-wave stimuli in the electrical stimulation-induced paw flexion (EPF) test in mice. The fixed sine-wave electric stimulations of 5 Hz (C-fiber), 250 Hz (Aδ-fiber) and 2000 Hz (Aβ-fiber...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsumoto, Misaki, Inoue, Makoto, Hald, Andreas, Yamaguchi, Asuka, Ueda, Hiroshi
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1482679/
https://www.ncbi.nlm.nih.gov/pubmed/16681855
http://dx.doi.org/10.1186/1744-8069-2-16
_version_ 1782128286317412352
author Matsumoto, Misaki
Inoue, Makoto
Hald, Andreas
Yamaguchi, Asuka
Ueda, Hiroshi
author_facet Matsumoto, Misaki
Inoue, Makoto
Hald, Andreas
Yamaguchi, Asuka
Ueda, Hiroshi
author_sort Matsumoto, Misaki
collection PubMed
description In the present study, we first report an in vivo characterization of flexor responses induced by three distinct sine-wave stimuli in the electrical stimulation-induced paw flexion (EPF) test in mice. The fixed sine-wave electric stimulations of 5 Hz (C-fiber), 250 Hz (Aδ-fiber) and 2000 Hz (Aβ-fiber) to the hind paw of mice induced a paw-flexion response and vocalization. The average threshold for paw flexor responses by sine-wave stimulations was much lower than that for vocalization. Neonatally (P3) pretreatment with capsaicin to degenerate polymodal substance P-ergic C-fiber neurons increased the threshold to 5 Hz (C-fiber) stimuli, but not to 250 Hz (Aδ-fiber) and 2000 Hz (Aβ-fiber). The flexor responses to 5 Hz stimuli were significantly blocked by intrathecal (i.t.) pretreatment with both CP-99994 and MK-801, an NK1 and NMDA receptor antagonist, respectively, but not by CNQX, an AMPA/kainate receptor antagonist. On the other hand, the flexor responses induced by 250 Hz stimuli were blocked by MK-801 (i.t.) but not by CP-99994 or CNQX. In contrast, flexor responses induced by 2000 Hz stimuli were only blocked by CNQX treatment. These data suggest that we have identified three pharmacologically different categories of responses mediated through different primary afferent fibers. Furthermore, we also carried out characterization of the in vivo functional sensitivity of each of the sensory fiber types in nerve-injured mice using the EPF test, and found that the threshold to both 250 Hz and 2000 Hz stimulations were markedly decreased, whereas the threshold to 5 Hz stimulations was significantly increased. Thus we found opposing effects on specific sensory fiber-mediated responses as a result of nerve injury in mice. These results also suggest that the EPF analysis is useful for the evaluation of plasticity in sensory functions in animal disease models.
format Text
id pubmed-1482679
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-14826792006-06-24 Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test Matsumoto, Misaki Inoue, Makoto Hald, Andreas Yamaguchi, Asuka Ueda, Hiroshi Mol Pain Short Report In the present study, we first report an in vivo characterization of flexor responses induced by three distinct sine-wave stimuli in the electrical stimulation-induced paw flexion (EPF) test in mice. The fixed sine-wave electric stimulations of 5 Hz (C-fiber), 250 Hz (Aδ-fiber) and 2000 Hz (Aβ-fiber) to the hind paw of mice induced a paw-flexion response and vocalization. The average threshold for paw flexor responses by sine-wave stimulations was much lower than that for vocalization. Neonatally (P3) pretreatment with capsaicin to degenerate polymodal substance P-ergic C-fiber neurons increased the threshold to 5 Hz (C-fiber) stimuli, but not to 250 Hz (Aδ-fiber) and 2000 Hz (Aβ-fiber). The flexor responses to 5 Hz stimuli were significantly blocked by intrathecal (i.t.) pretreatment with both CP-99994 and MK-801, an NK1 and NMDA receptor antagonist, respectively, but not by CNQX, an AMPA/kainate receptor antagonist. On the other hand, the flexor responses induced by 250 Hz stimuli were blocked by MK-801 (i.t.) but not by CP-99994 or CNQX. In contrast, flexor responses induced by 2000 Hz stimuli were only blocked by CNQX treatment. These data suggest that we have identified three pharmacologically different categories of responses mediated through different primary afferent fibers. Furthermore, we also carried out characterization of the in vivo functional sensitivity of each of the sensory fiber types in nerve-injured mice using the EPF test, and found that the threshold to both 250 Hz and 2000 Hz stimulations were markedly decreased, whereas the threshold to 5 Hz stimulations was significantly increased. Thus we found opposing effects on specific sensory fiber-mediated responses as a result of nerve injury in mice. These results also suggest that the EPF analysis is useful for the evaluation of plasticity in sensory functions in animal disease models. BioMed Central 2006-05-08 /pmc/articles/PMC1482679/ /pubmed/16681855 http://dx.doi.org/10.1186/1744-8069-2-16 Text en Copyright © 2006 Matsumoto et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Report
Matsumoto, Misaki
Inoue, Makoto
Hald, Andreas
Yamaguchi, Asuka
Ueda, Hiroshi
Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title_full Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title_fullStr Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title_full_unstemmed Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title_short Characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
title_sort characterization of three different sensory fibers by use of neonatal capsaicin treatment, spinal antagonism and a novel electrical stimulation-induced paw flexion test
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1482679/
https://www.ncbi.nlm.nih.gov/pubmed/16681855
http://dx.doi.org/10.1186/1744-8069-2-16
work_keys_str_mv AT matsumotomisaki characterizationofthreedifferentsensoryfibersbyuseofneonatalcapsaicintreatmentspinalantagonismandanovelelectricalstimulationinducedpawflexiontest
AT inouemakoto characterizationofthreedifferentsensoryfibersbyuseofneonatalcapsaicintreatmentspinalantagonismandanovelelectricalstimulationinducedpawflexiontest
AT haldandreas characterizationofthreedifferentsensoryfibersbyuseofneonatalcapsaicintreatmentspinalantagonismandanovelelectricalstimulationinducedpawflexiontest
AT yamaguchiasuka characterizationofthreedifferentsensoryfibersbyuseofneonatalcapsaicintreatmentspinalantagonismandanovelelectricalstimulationinducedpawflexiontest
AT uedahiroshi characterizationofthreedifferentsensoryfibersbyuseofneonatalcapsaicintreatmentspinalantagonismandanovelelectricalstimulationinducedpawflexiontest