Cargando…
Nonlinear analysis of biomagnetic signals recorded from uterine myomas
OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with lar...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1484479/ https://www.ncbi.nlm.nih.gov/pubmed/16571144 http://dx.doi.org/10.1186/1477-044X-4-2 |
_version_ | 1782128330850435072 |
---|---|
author | Kotini, Athanasia Anastasiadis, Achilleas N Anninos, Photios Koutlaki, Nikoleta Anastasiadis, Panagiotis |
author_facet | Kotini, Athanasia Anastasiadis, Achilleas N Anninos, Photios Koutlaki, Nikoleta Anastasiadis, Panagiotis |
author_sort | Kotini, Athanasia |
collection | PubMed |
description | OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with large myomas and 8 with small ones. Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI<1.45). RESULTS: Applying nonlinear analysis to the biomagnetic signals of the uterine myomas, we observed a clear saturation value for the group of large ones (mean = 11.35 ± 1.49) and no saturation for the small ones. CONCLUSION: The comparison of the saturation values in the biomagnetic recordings of large and small myomas may be a valuable tool in the evaluation of functional changes in their dynamic behavior. |
format | Text |
id | pubmed-1484479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-14844792006-07-01 Nonlinear analysis of biomagnetic signals recorded from uterine myomas Kotini, Athanasia Anastasiadis, Achilleas N Anninos, Photios Koutlaki, Nikoleta Anastasiadis, Panagiotis Biomagn Res Technol Research OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with large myomas and 8 with small ones. Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI<1.45). RESULTS: Applying nonlinear analysis to the biomagnetic signals of the uterine myomas, we observed a clear saturation value for the group of large ones (mean = 11.35 ± 1.49) and no saturation for the small ones. CONCLUSION: The comparison of the saturation values in the biomagnetic recordings of large and small myomas may be a valuable tool in the evaluation of functional changes in their dynamic behavior. BioMed Central 2006-03-30 /pmc/articles/PMC1484479/ /pubmed/16571144 http://dx.doi.org/10.1186/1477-044X-4-2 Text en Copyright © 2006 Kotini et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Kotini, Athanasia Anastasiadis, Achilleas N Anninos, Photios Koutlaki, Nikoleta Anastasiadis, Panagiotis Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title | Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title_full | Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title_fullStr | Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title_full_unstemmed | Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title_short | Nonlinear analysis of biomagnetic signals recorded from uterine myomas |
title_sort | nonlinear analysis of biomagnetic signals recorded from uterine myomas |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1484479/ https://www.ncbi.nlm.nih.gov/pubmed/16571144 http://dx.doi.org/10.1186/1477-044X-4-2 |
work_keys_str_mv | AT kotiniathanasia nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas AT anastasiadisachilleasn nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas AT anninosphotios nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas AT koutlakinikoleta nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas AT anastasiadispanagiotis nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas |