Cargando…

Nonlinear analysis of biomagnetic signals recorded from uterine myomas

OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with lar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kotini, Athanasia, Anastasiadis, Achilleas N, Anninos, Photios, Koutlaki, Nikoleta, Anastasiadis, Panagiotis
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1484479/
https://www.ncbi.nlm.nih.gov/pubmed/16571144
http://dx.doi.org/10.1186/1477-044X-4-2
_version_ 1782128330850435072
author Kotini, Athanasia
Anastasiadis, Achilleas N
Anninos, Photios
Koutlaki, Nikoleta
Anastasiadis, Panagiotis
author_facet Kotini, Athanasia
Anastasiadis, Achilleas N
Anninos, Photios
Koutlaki, Nikoleta
Anastasiadis, Panagiotis
author_sort Kotini, Athanasia
collection PubMed
description OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with large myomas and 8 with small ones. Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI<1.45). RESULTS: Applying nonlinear analysis to the biomagnetic signals of the uterine myomas, we observed a clear saturation value for the group of large ones (mean = 11.35 ± 1.49) and no saturation for the small ones. CONCLUSION: The comparison of the saturation values in the biomagnetic recordings of large and small myomas may be a valuable tool in the evaluation of functional changes in their dynamic behavior.
format Text
id pubmed-1484479
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-14844792006-07-01 Nonlinear analysis of biomagnetic signals recorded from uterine myomas Kotini, Athanasia Anastasiadis, Achilleas N Anninos, Photios Koutlaki, Nikoleta Anastasiadis, Panagiotis Biomagn Res Technol Research OBJECTIVE: To determine if there is any non-linearity in the biomagnetic recordings of uterine myomas and to find any differences that may be present in the mechanisms underlying their signal dynamics. METHODS: Twenty-four women were included in the study. Sixteen of them were characterised with large myomas and 8 with small ones. Uterine artery waveform measurements were evaluated by use of Pulsatility Index (PI) (normal value PI<1.45). RESULTS: Applying nonlinear analysis to the biomagnetic signals of the uterine myomas, we observed a clear saturation value for the group of large ones (mean = 11.35 ± 1.49) and no saturation for the small ones. CONCLUSION: The comparison of the saturation values in the biomagnetic recordings of large and small myomas may be a valuable tool in the evaluation of functional changes in their dynamic behavior. BioMed Central 2006-03-30 /pmc/articles/PMC1484479/ /pubmed/16571144 http://dx.doi.org/10.1186/1477-044X-4-2 Text en Copyright © 2006 Kotini et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Kotini, Athanasia
Anastasiadis, Achilleas N
Anninos, Photios
Koutlaki, Nikoleta
Anastasiadis, Panagiotis
Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title_full Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title_fullStr Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title_full_unstemmed Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title_short Nonlinear analysis of biomagnetic signals recorded from uterine myomas
title_sort nonlinear analysis of biomagnetic signals recorded from uterine myomas
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1484479/
https://www.ncbi.nlm.nih.gov/pubmed/16571144
http://dx.doi.org/10.1186/1477-044X-4-2
work_keys_str_mv AT kotiniathanasia nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas
AT anastasiadisachilleasn nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas
AT anninosphotios nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas
AT koutlakinikoleta nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas
AT anastasiadispanagiotis nonlinearanalysisofbiomagneticsignalsrecordedfromuterinemyomas