Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1550901/ https://www.ncbi.nlm.nih.gov/pubmed/16684373 http://dx.doi.org/10.1186/cc4911 |
_version_ | 1782129299839516672 |
---|---|
author | Martínez-Simón, Antonio Monedero, Pablo Cacho-Asenjo, Elena |
author_facet | Martínez-Simón, Antonio Monedero, Pablo Cacho-Asenjo, Elena |
author_sort | Martínez-Simón, Antonio |
collection | PubMed |
description | |
format | Text |
id | pubmed-1550901 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-15509012006-08-22 Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report Martínez-Simón, Antonio Monedero, Pablo Cacho-Asenjo, Elena Crit Care Letter BioMed Central 2006 2006-04-27 /pmc/articles/PMC1550901/ /pubmed/16684373 http://dx.doi.org/10.1186/cc4911 Text en Copyright © 2006 BioMed Central Ltd |
spellingShingle | Letter Martínez-Simón, Antonio Monedero, Pablo Cacho-Asenjo, Elena Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title | Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title_full | Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title_fullStr | Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title_full_unstemmed | Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title_short | Erroneous measurement of haemodynamic parameters by PiCCO™ monitor in a critically ill patient with renal replacement therapy: a case report |
title_sort | erroneous measurement of haemodynamic parameters by picco™ monitor in a critically ill patient with renal replacement therapy: a case report |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1550901/ https://www.ncbi.nlm.nih.gov/pubmed/16684373 http://dx.doi.org/10.1186/cc4911 |
work_keys_str_mv | AT martinezsimonantonio erroneousmeasurementofhaemodynamicparametersbypiccomonitorinacriticallyillpatientwithrenalreplacementtherapyacasereport AT monederopablo erroneousmeasurementofhaemodynamicparametersbypiccomonitorinacriticallyillpatientwithrenalreplacementtherapyacasereport AT cachoasenjoelena erroneousmeasurementofhaemodynamicparametersbypiccomonitorinacriticallyillpatientwithrenalreplacementtherapyacasereport |