Cargando…
Reuse of Occluded Veins During Permanent Pacemaker Lead Extraction: A New Indication for Femoral Lead Extraction
Thirty-four patients had 57 leads extracted using a femoral approach. In those patients requiring immediate replacement of a pacing lead access for a new lead was achieved in all cases by loosely attaching a guide wire and dragging it into the right atrium behind the explanted lead. A sheath was the...
Autores principales: | Staniforth, Andrew D, Schilling, Richard J |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Indian Pacing and Electrophysiology Group
2002
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1557418/ https://www.ncbi.nlm.nih.gov/pubmed/16951725 |
Ejemplares similares
-
Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads
por: Paraskevaidis, Stylianos, et al.
Publicado: (2014) -
Occluded vein as a predictor for complications in non-infectious transvenous lead extraction
por: Milman, Anat, et al.
Publicado: (2022) -
Remnant Pacemaker Lead Tips after Lead Extractions in Pacemaker Infections
por: Kim, Daehoon, et al.
Publicado: (2016) -
Persistent fever after pacemaker lead extraction
por: Nunes, Maria Carmo Pereira, et al.
Publicado: (2016) -
Unusual embolization of a pacemaker lead fragment during lead extraction
por: Yap, Sing-Chien, et al.
Publicado: (2015)