An approach to management of critical indoor air problems in school buildings.
This study was conducted in a school center that had been the focus of intense public concern over 2 years because of suspected mold and health problems. Because several attempts to find solutions to the problem within the community were not satisfactory, outside specialists were needed for support...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
1999
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1566231/ https://www.ncbi.nlm.nih.gov/pubmed/10423392 |
_version_ | 1782129577815965696 |
---|---|
author | Haverinen, U Husman, T Toivola, M Suonketo, J Pentti, M Lindberg, R Leinonen, J Hyvärinen, A Meklin, T Nevalainen, A |
author_facet | Haverinen, U Husman, T Toivola, M Suonketo, J Pentti, M Lindberg, R Leinonen, J Hyvärinen, A Meklin, T Nevalainen, A |
author_sort | Haverinen, U |
collection | PubMed |
description | This study was conducted in a school center that had been the focus of intense public concern over 2 years because of suspected mold and health problems. Because several attempts to find solutions to the problem within the community were not satisfactory, outside specialists were needed for support in solving the problem. The study group consisted of experts in civil engineering, indoor mycology, and epidemiology. The studies were conducted in close cooperation with the city administration. Structures at risk were opened, moisture and temperature were measured, and the causes of damage were analyzed. Microbial samples were taken from the air, surfaces, and materials. Health questionnaires were sent to the schoolchildren and personnel. Information on the measurements and their results was released regularly to school employees, students and their parents, and to the media. Repairs were designed on the basis of this information. Moisture damage was caused mainly by difficult moisture conditions at the building site, poor ventilation, and water leaks. Fungal genera (concentrations <200 colony-forming units (cfu)/m(3), <3000 cfu/cm(2)) typical to buildings with mold problems (e.g., Aspergillus versicolor, Eurotium) were collected from the indoor air and surfaces of the school buildings. Where moisture-prone structures were identified and visible signs of damage or elevated moisture content were recorded, the numbers of microbes also were high; thus microbial results from material samples supported the conclusions made in the structural studies. Several irritative and recurrent symptoms were common among the upper secondary and high school students. The prevalence of asthma was high (13%) among the upper secondary school students. During the last 4 years, the incidence of asthma was 3-fold that of the previous 4-year period. |
format | Text |
id | pubmed-1566231 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1999 |
record_format | MEDLINE/PubMed |
spelling | pubmed-15662312006-09-19 An approach to management of critical indoor air problems in school buildings. Haverinen, U Husman, T Toivola, M Suonketo, J Pentti, M Lindberg, R Leinonen, J Hyvärinen, A Meklin, T Nevalainen, A Environ Health Perspect Research Article This study was conducted in a school center that had been the focus of intense public concern over 2 years because of suspected mold and health problems. Because several attempts to find solutions to the problem within the community were not satisfactory, outside specialists were needed for support in solving the problem. The study group consisted of experts in civil engineering, indoor mycology, and epidemiology. The studies were conducted in close cooperation with the city administration. Structures at risk were opened, moisture and temperature were measured, and the causes of damage were analyzed. Microbial samples were taken from the air, surfaces, and materials. Health questionnaires were sent to the schoolchildren and personnel. Information on the measurements and their results was released regularly to school employees, students and their parents, and to the media. Repairs were designed on the basis of this information. Moisture damage was caused mainly by difficult moisture conditions at the building site, poor ventilation, and water leaks. Fungal genera (concentrations <200 colony-forming units (cfu)/m(3), <3000 cfu/cm(2)) typical to buildings with mold problems (e.g., Aspergillus versicolor, Eurotium) were collected from the indoor air and surfaces of the school buildings. Where moisture-prone structures were identified and visible signs of damage or elevated moisture content were recorded, the numbers of microbes also were high; thus microbial results from material samples supported the conclusions made in the structural studies. Several irritative and recurrent symptoms were common among the upper secondary and high school students. The prevalence of asthma was high (13%) among the upper secondary school students. During the last 4 years, the incidence of asthma was 3-fold that of the previous 4-year period. 1999-06 /pmc/articles/PMC1566231/ /pubmed/10423392 Text en |
spellingShingle | Research Article Haverinen, U Husman, T Toivola, M Suonketo, J Pentti, M Lindberg, R Leinonen, J Hyvärinen, A Meklin, T Nevalainen, A An approach to management of critical indoor air problems in school buildings. |
title | An approach to management of critical indoor air problems in school buildings. |
title_full | An approach to management of critical indoor air problems in school buildings. |
title_fullStr | An approach to management of critical indoor air problems in school buildings. |
title_full_unstemmed | An approach to management of critical indoor air problems in school buildings. |
title_short | An approach to management of critical indoor air problems in school buildings. |
title_sort | approach to management of critical indoor air problems in school buildings. |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1566231/ https://www.ncbi.nlm.nih.gov/pubmed/10423392 |
work_keys_str_mv | AT haverinenu anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT husmant anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT toivolam anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT suonketoj anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT penttim anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT lindbergr anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT leinonenj anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT hyvarinena anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT meklint anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT nevalainena anapproachtomanagementofcriticalindoorairproblemsinschoolbuildings AT haverinenu approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT husmant approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT toivolam approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT suonketoj approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT penttim approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT lindbergr approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT leinonenj approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT hyvarinena approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT meklint approachtomanagementofcriticalindoorairproblemsinschoolbuildings AT nevalainena approachtomanagementofcriticalindoorairproblemsinschoolbuildings |