The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.

We assessed the reproducibility of X-ray fluorescence-based lead measurements from multiple measurements made on a low-concentration plaster of paris phantom and in five subjects measured five times on two occasions. Over a 6-month period, 220 measurements of the same phantom were obtained and showe...

Descripción completa

Detalles Bibliográficos
Autores principales: Gordon, C L, Webber, C E, Chettle, D R
Formato: Texto
Lenguaje:English
Publicado: 1994
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1567330/
https://www.ncbi.nlm.nih.gov/pubmed/7895710
_version_ 1782129805230080000
author Gordon, C L
Webber, C E
Chettle, D R
author_facet Gordon, C L
Webber, C E
Chettle, D R
author_sort Gordon, C L
collection PubMed
description We assessed the reproducibility of X-ray fluorescence-based lead measurements from multiple measurements made on a low-concentration plaster of paris phantom and in five subjects measured five times on two occasions. Over a 6-month period, 220 measurements of the same phantom were obtained and showed a standard deviation of 1.29 micrograms Pb (g plaster of paris)-1. The two sets of in vivo measurements were made 10 months apart and revealed a mean standard deviation of 3.4 micrograms Pb (g bone mineral)-1 and 5.1 micrograms Pb (g bone mineral)-1 for males and females, respectively. Our measured standard deviation exceeded by 20-30% the calculated standard deviation associated with a single measurement both in the phantom and in subjects. This indicates that some variance is introduced during the measurement process. Operator learning and consistency significantly minimized this increased variability. Measured lead concentrations of the left and right tibia in 14 subjects showed no significant differences between legs. As a result, either tibia can be sampled and compared over time. The levels of reproducibility we report here mean that X-ray fluorescence-based determinations of bone lead concentrations are reliable both over the short and long term. Thus, reasonably sized confidence intervals can be placed on detected changes in concentration and should permit acquisition of longitudinal data within a reasonable length of time.
format Text
id pubmed-1567330
institution National Center for Biotechnology Information
language English
publishDate 1994
record_format MEDLINE/PubMed
spelling pubmed-15673302006-09-19 The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead. Gordon, C L Webber, C E Chettle, D R Environ Health Perspect Research Article We assessed the reproducibility of X-ray fluorescence-based lead measurements from multiple measurements made on a low-concentration plaster of paris phantom and in five subjects measured five times on two occasions. Over a 6-month period, 220 measurements of the same phantom were obtained and showed a standard deviation of 1.29 micrograms Pb (g plaster of paris)-1. The two sets of in vivo measurements were made 10 months apart and revealed a mean standard deviation of 3.4 micrograms Pb (g bone mineral)-1 and 5.1 micrograms Pb (g bone mineral)-1 for males and females, respectively. Our measured standard deviation exceeded by 20-30% the calculated standard deviation associated with a single measurement both in the phantom and in subjects. This indicates that some variance is introduced during the measurement process. Operator learning and consistency significantly minimized this increased variability. Measured lead concentrations of the left and right tibia in 14 subjects showed no significant differences between legs. As a result, either tibia can be sampled and compared over time. The levels of reproducibility we report here mean that X-ray fluorescence-based determinations of bone lead concentrations are reliable both over the short and long term. Thus, reasonably sized confidence intervals can be placed on detected changes in concentration and should permit acquisition of longitudinal data within a reasonable length of time. 1994-08 /pmc/articles/PMC1567330/ /pubmed/7895710 Text en
spellingShingle Research Article
Gordon, C L
Webber, C E
Chettle, D R
The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title_full The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title_fullStr The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title_full_unstemmed The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title_short The reproducibility of 109Cd-based X-ray fluorescence measurements of bone lead.
title_sort reproducibility of 109cd-based x-ray fluorescence measurements of bone lead.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1567330/
https://www.ncbi.nlm.nih.gov/pubmed/7895710
work_keys_str_mv AT gordoncl thereproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead
AT webberce thereproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead
AT chettledr thereproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead
AT gordoncl reproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead
AT webberce reproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead
AT chettledr reproducibilityof109cdbasedxrayfluorescencemeasurementsofbonelead