Cargando…

Engineering and operating approaches for controlling asbestos fibers in drinking water.

Techniques are available to minimize the concentration of asbestos fibers in drinking water. Filtration research conducted at locations on Lake Superior and in the Cascade Mountains in Washington has shown that amphibole and chrysotile fibers can be removed by granular media filtration. Removal perc...

Descripción completa

Detalles Bibliográficos
Autor principal: Logsdon, G S
Formato: Texto
Lenguaje:English
Publicado: 1983
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1569079/
https://www.ncbi.nlm.nih.gov/pubmed/6559130
_version_ 1782130137768132608
author Logsdon, G S
author_facet Logsdon, G S
author_sort Logsdon, G S
collection PubMed
description Techniques are available to minimize the concentration of asbestos fibers in drinking water. Filtration research conducted at locations on Lake Superior and in the Cascade Mountains in Washington has shown that amphibole and chrysotile fibers can be removed by granular media filtration. Removal percentages can exceed 99% when the raw water is coagulated properly and the filtered water turbidity is 0.10 ntu (nephelometric turbidity units) or lower. Filtered water fiber counts below detectable limits of 0.1 to 0.01 X 10(6) fibers/L can be attained. A study by the Metropolitan Water District of Southern California showed that when raw water chrysotile counts ranged from 200 X 10(6) fibers/L to 2000 X 10(6) fibers/L, filtered water fiber counts frequently exceeded 1 X 10(6) fibers/L. Even so, striving to attain a filtered water turbidity of 0.1 ntu resulted in improved fiber removal. Pilot scale and distribution system research projects have shown that asbestos cement (AC) pipes can be protected from dissolution and leaching effects that can result in release of asbestos fibers into drinking water. Suggested techniques include modifying low pH, low alkalinity waters so they are not aggressive; coating the pipe wall with a chemical precipitate; and applying a cement mortar lining to the pipe wall. Operation and maintenance practices related to the distribution system, when AC water mains are in service, can influence the fiber count in tapwater. Main flushing can stir up sediment that accumulates in low-flow and dead-end areas, raising the fiber count. If mains are tapped and the cuttings are not flushed away through the tapping machine, but are instead permitted to fall into the water main, the fiber count can be raised.
format Text
id pubmed-1569079
institution National Center for Biotechnology Information
language English
publishDate 1983
record_format MEDLINE/PubMed
spelling pubmed-15690792006-09-18 Engineering and operating approaches for controlling asbestos fibers in drinking water. Logsdon, G S Environ Health Perspect Research Article Techniques are available to minimize the concentration of asbestos fibers in drinking water. Filtration research conducted at locations on Lake Superior and in the Cascade Mountains in Washington has shown that amphibole and chrysotile fibers can be removed by granular media filtration. Removal percentages can exceed 99% when the raw water is coagulated properly and the filtered water turbidity is 0.10 ntu (nephelometric turbidity units) or lower. Filtered water fiber counts below detectable limits of 0.1 to 0.01 X 10(6) fibers/L can be attained. A study by the Metropolitan Water District of Southern California showed that when raw water chrysotile counts ranged from 200 X 10(6) fibers/L to 2000 X 10(6) fibers/L, filtered water fiber counts frequently exceeded 1 X 10(6) fibers/L. Even so, striving to attain a filtered water turbidity of 0.1 ntu resulted in improved fiber removal. Pilot scale and distribution system research projects have shown that asbestos cement (AC) pipes can be protected from dissolution and leaching effects that can result in release of asbestos fibers into drinking water. Suggested techniques include modifying low pH, low alkalinity waters so they are not aggressive; coating the pipe wall with a chemical precipitate; and applying a cement mortar lining to the pipe wall. Operation and maintenance practices related to the distribution system, when AC water mains are in service, can influence the fiber count in tapwater. Main flushing can stir up sediment that accumulates in low-flow and dead-end areas, raising the fiber count. If mains are tapped and the cuttings are not flushed away through the tapping machine, but are instead permitted to fall into the water main, the fiber count can be raised. 1983-11 /pmc/articles/PMC1569079/ /pubmed/6559130 Text en
spellingShingle Research Article
Logsdon, G S
Engineering and operating approaches for controlling asbestos fibers in drinking water.
title Engineering and operating approaches for controlling asbestos fibers in drinking water.
title_full Engineering and operating approaches for controlling asbestos fibers in drinking water.
title_fullStr Engineering and operating approaches for controlling asbestos fibers in drinking water.
title_full_unstemmed Engineering and operating approaches for controlling asbestos fibers in drinking water.
title_short Engineering and operating approaches for controlling asbestos fibers in drinking water.
title_sort engineering and operating approaches for controlling asbestos fibers in drinking water.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1569079/
https://www.ncbi.nlm.nih.gov/pubmed/6559130
work_keys_str_mv AT logsdongs engineeringandoperatingapproachesforcontrollingasbestosfibersindrinkingwater