Cargando…

Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiogra...

Descripción completa

Detalles Bibliográficos
Autores principales: Minardi, Giovanni, Manzara, Carla, Creazzo, Vittorio, Maselli, Daniele, Casali, Giovanni, Pulignano, Giovanni, Musumeci, Francesco
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1586008/
https://www.ncbi.nlm.nih.gov/pubmed/16984626
http://dx.doi.org/10.1186/1749-8090-1-27
_version_ 1782130341530566656
author Minardi, Giovanni
Manzara, Carla
Creazzo, Vittorio
Maselli, Daniele
Casali, Giovanni
Pulignano, Giovanni
Musumeci, Francesco
author_facet Minardi, Giovanni
Manzara, Carla
Creazzo, Vittorio
Maselli, Daniele
Casali, Giovanni
Pulignano, Giovanni
Musumeci, Francesco
author_sort Minardi, Giovanni
collection PubMed
description BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm(2) and 0.76 ± 0.2 cm(2)/m(2); DVI was normal (0.50 ± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m(2) to 191 ± 23.8g and 114.5 ± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg), MnPG (up to 43.2 ± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm(2), 0.75 ± 0.3cm(2)/m(2) and 0.48 ± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression.
format Text
id pubmed-1586008
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-15860082006-09-30 Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography Minardi, Giovanni Manzara, Carla Creazzo, Vittorio Maselli, Daniele Casali, Giovanni Pulignano, Giovanni Musumeci, Francesco J Cardiothorac Surg Case Study BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm(2) and 0.76 ± 0.2 cm(2)/m(2); DVI was normal (0.50 ± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m(2) to 191 ± 23.8g and 114.5 ± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg), MnPG (up to 43.2 ± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm(2), 0.75 ± 0.3cm(2)/m(2) and 0.48 ± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression. BioMed Central 2006-09-19 /pmc/articles/PMC1586008/ /pubmed/16984626 http://dx.doi.org/10.1186/1749-8090-1-27 Text en Copyright © 2006 Minardi et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Study
Minardi, Giovanni
Manzara, Carla
Creazzo, Vittorio
Maselli, Daniele
Casali, Giovanni
Pulignano, Giovanni
Musumeci, Francesco
Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title_full Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title_fullStr Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title_full_unstemmed Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title_short Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
title_sort evaluation of 17-mm st. jude medical regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography
topic Case Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1586008/
https://www.ncbi.nlm.nih.gov/pubmed/16984626
http://dx.doi.org/10.1186/1749-8090-1-27
work_keys_str_mv AT minardigiovanni evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT manzaracarla evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT creazzovittorio evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT masellidaniele evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT casaligiovanni evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT pulignanogiovanni evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography
AT musumecifrancesco evaluationof17mmstjudemedicalregentprostheticaorticheartvalvesbyrestanddobutaminestressechocardiography