Cargando…
OSCA: a comprehensive open-access system of analysis of posterior capsular opacification
BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2006
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1592309/ https://www.ncbi.nlm.nih.gov/pubmed/16875500 http://dx.doi.org/10.1186/1471-2415-6-30 |
_version_ | 1782130396036595712 |
---|---|
author | Aslam, Tariq M Patton, Niall Rose, Christopher J |
author_facet | Aslam, Tariq M Patton, Niall Rose, Christopher J |
author_sort | Aslam, Tariq M |
collection | PubMed |
description | BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis. METHODS: Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed. RESULTS: Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated. CONCLUSION: This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability. |
format | Text |
id | pubmed-1592309 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2006 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-15923092006-10-06 OSCA: a comprehensive open-access system of analysis of posterior capsular opacification Aslam, Tariq M Patton, Niall Rose, Christopher J BMC Ophthalmol Research Article BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis. METHODS: Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed. RESULTS: Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated. CONCLUSION: This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability. BioMed Central 2006-08-23 /pmc/articles/PMC1592309/ /pubmed/16875500 http://dx.doi.org/10.1186/1471-2415-6-30 Text en Copyright © 2006 Aslam et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Aslam, Tariq M Patton, Niall Rose, Christopher J OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title | OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title_full | OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title_fullStr | OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title_full_unstemmed | OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title_short | OSCA: a comprehensive open-access system of analysis of posterior capsular opacification |
title_sort | osca: a comprehensive open-access system of analysis of posterior capsular opacification |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1592309/ https://www.ncbi.nlm.nih.gov/pubmed/16875500 http://dx.doi.org/10.1186/1471-2415-6-30 |
work_keys_str_mv | AT aslamtariqm oscaacomprehensiveopenaccesssystemofanalysisofposteriorcapsularopacification AT pattonniall oscaacomprehensiveopenaccesssystemofanalysisofposteriorcapsularopacification AT rosechristopherj oscaacomprehensiveopenaccesssystemofanalysisofposteriorcapsularopacification |