In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals

BACKGROUND: We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. METHODS: We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wir...

Descripción completa

Detalles Bibliográficos
Autores principales: Tangwongsan, Chanchana, Chachati, Louay, Webster, John G, Farrell, Patrick V
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1635717/
https://www.ncbi.nlm.nih.gov/pubmed/17067386
http://dx.doi.org/10.1186/1475-925X-5-57
_version_ 1782130709016608768
author Tangwongsan, Chanchana
Chachati, Louay
Webster, John G
Farrell, Patrick V
author_facet Tangwongsan, Chanchana
Chachati, Louay
Webster, John G
Farrell, Patrick V
author_sort Tangwongsan, Chanchana
collection PubMed
description BACKGROUND: We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. METHODS: We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wire anemometer circuit. One arm is connected to a steerable catheter sensor whose tip is a 1.9 mm × 3.2 mm thin film resistive temperature detector (RTD) sensor. We used a circulation system to simulate different flow rates at 39°C for in vitro experiments using distilled water, tap water and saline. We heated the sensor approximately 5°C above the fluid temperature. We measured the power consumed by the sensor and the resistance of the sensor during the experiments and analyzed these data to determine the value of the convective heat transfer coefficient at various flow rates. RESULTS: From 0 to 5 L/min, experimental values of h in W/(m(2)·K) were for distilled water 5100 to 13000, for tap water 5500 to 12300, and for saline 5400 to 13600. Theoretical values were 1900 to 10700. CONCLUSION: We believe this system is the smallest, most accurate method of minimally invasive measurement of in vivo h in animals and provides the least disturbance of flow.
format Text
id pubmed-1635717
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-16357172006-11-14 In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals Tangwongsan, Chanchana Chachati, Louay Webster, John G Farrell, Patrick V Biomed Eng Online Research BACKGROUND: We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. METHODS: We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wire anemometer circuit. One arm is connected to a steerable catheter sensor whose tip is a 1.9 mm × 3.2 mm thin film resistive temperature detector (RTD) sensor. We used a circulation system to simulate different flow rates at 39°C for in vitro experiments using distilled water, tap water and saline. We heated the sensor approximately 5°C above the fluid temperature. We measured the power consumed by the sensor and the resistance of the sensor during the experiments and analyzed these data to determine the value of the convective heat transfer coefficient at various flow rates. RESULTS: From 0 to 5 L/min, experimental values of h in W/(m(2)·K) were for distilled water 5100 to 13000, for tap water 5500 to 12300, and for saline 5400 to 13600. Theoretical values were 1900 to 10700. CONCLUSION: We believe this system is the smallest, most accurate method of minimally invasive measurement of in vivo h in animals and provides the least disturbance of flow. BioMed Central 2006-10-26 /pmc/articles/PMC1635717/ /pubmed/17067386 http://dx.doi.org/10.1186/1475-925X-5-57 Text en Copyright © 2006 Tangwongsan et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Tangwongsan, Chanchana
Chachati, Louay
Webster, John G
Farrell, Patrick V
In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title_full In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title_fullStr In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title_full_unstemmed In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title_short In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
title_sort in vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1635717/
https://www.ncbi.nlm.nih.gov/pubmed/17067386
http://dx.doi.org/10.1186/1475-925X-5-57
work_keys_str_mv AT tangwongsanchanchana invitrocalibrationofasystemformeasurementofinvivoconvectiveheattransfercoefficientinanimals
AT chachatilouay invitrocalibrationofasystemformeasurementofinvivoconvectiveheattransfercoefficientinanimals
AT websterjohng invitrocalibrationofasystemformeasurementofinvivoconvectiveheattransfercoefficientinanimals
AT farrellpatrickv invitrocalibrationofasystemformeasurementofinvivoconvectiveheattransfercoefficientinanimals