Cargando…

Measurement variability associated with KXRF bone lead measurement in young adults.

In vivo bone lead measurement using K X-ray fluorescence (KXRF) has been used to estimate long-term lead exposure, especially in adults. Relatively few studies have been conducted on young subjects with this technique. To explore the measurement variability of KXRF bone lead measurements in young su...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoppin, J A, Aro, A, Hu, H, Ryan, P B
Formato: Texto
Lenguaje:English
Publicado: 2000
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1637955/
https://www.ncbi.nlm.nih.gov/pubmed/10706530
_version_ 1782130947333816320
author Hoppin, J A
Aro, A
Hu, H
Ryan, P B
author_facet Hoppin, J A
Aro, A
Hu, H
Ryan, P B
author_sort Hoppin, J A
collection PubMed
description In vivo bone lead measurement using K X-ray fluorescence (KXRF) has been used to estimate long-term lead exposure, especially in adults. Relatively few studies have been conducted on young subjects with this technique. To explore the measurement variability of KXRF bone lead measurements in young subjects, the tibiae of two male cadavers from Boston, Massachusetts, 17 and 20 years of age, were obtained for repeated bone lead measurements. Bone lead concentrations were measured using a grid of nine locations, 1 cm apart, centered at the midpoint of the tibia. Each location was sampled using five 60-min measurements. Measured concentrations ranged from < 0 to 11.8 microg Pb/g bone mineral across a tibia with mean concentrations for the midpoint locations of 0.8 microg Pb/g bone mineral SD = 2.5 and 2.0 microg Pb/g bone mineral (SD = 1.9) for the left and right legs of the younger subject and 3.6 microg Pb/g bone mineral (SD = 2.6) and 6.0 microg Pb/g bone mineral (SD = 3.3) for the left and right legs of the older subject. Although bone lead concentrations did not vary significantly by measurement location in an individual leg, reported measurement uncertainty increased significantly at locations that were 1 cm from the center of the tibia horizontally (p < 0.0001). Symmetry in bone lead concentration between legs was observed for the 17-year-old subject. Potential asymmetry between the left and right legs was suggested for the 20-year-old subject (p = 0.06). These data describe the degree of variability that may be associated with bone lead measurements of young subjects with low bone lead concentrations using a standard spot-source KXRF instrument. Because of the importance of conducting additional research on adolescent lead toxicity, further improvements to the precision of KXRF measurement are needed.
format Text
id pubmed-1637955
institution National Center for Biotechnology Information
language English
publishDate 2000
record_format MEDLINE/PubMed
spelling pubmed-16379552006-11-17 Measurement variability associated with KXRF bone lead measurement in young adults. Hoppin, J A Aro, A Hu, H Ryan, P B Environ Health Perspect Research Article In vivo bone lead measurement using K X-ray fluorescence (KXRF) has been used to estimate long-term lead exposure, especially in adults. Relatively few studies have been conducted on young subjects with this technique. To explore the measurement variability of KXRF bone lead measurements in young subjects, the tibiae of two male cadavers from Boston, Massachusetts, 17 and 20 years of age, were obtained for repeated bone lead measurements. Bone lead concentrations were measured using a grid of nine locations, 1 cm apart, centered at the midpoint of the tibia. Each location was sampled using five 60-min measurements. Measured concentrations ranged from < 0 to 11.8 microg Pb/g bone mineral across a tibia with mean concentrations for the midpoint locations of 0.8 microg Pb/g bone mineral SD = 2.5 and 2.0 microg Pb/g bone mineral (SD = 1.9) for the left and right legs of the younger subject and 3.6 microg Pb/g bone mineral (SD = 2.6) and 6.0 microg Pb/g bone mineral (SD = 3.3) for the left and right legs of the older subject. Although bone lead concentrations did not vary significantly by measurement location in an individual leg, reported measurement uncertainty increased significantly at locations that were 1 cm from the center of the tibia horizontally (p < 0.0001). Symmetry in bone lead concentration between legs was observed for the 17-year-old subject. Potential asymmetry between the left and right legs was suggested for the 20-year-old subject (p = 0.06). These data describe the degree of variability that may be associated with bone lead measurements of young subjects with low bone lead concentrations using a standard spot-source KXRF instrument. Because of the importance of conducting additional research on adolescent lead toxicity, further improvements to the precision of KXRF measurement are needed. 2000-03 /pmc/articles/PMC1637955/ /pubmed/10706530 Text en
spellingShingle Research Article
Hoppin, J A
Aro, A
Hu, H
Ryan, P B
Measurement variability associated with KXRF bone lead measurement in young adults.
title Measurement variability associated with KXRF bone lead measurement in young adults.
title_full Measurement variability associated with KXRF bone lead measurement in young adults.
title_fullStr Measurement variability associated with KXRF bone lead measurement in young adults.
title_full_unstemmed Measurement variability associated with KXRF bone lead measurement in young adults.
title_short Measurement variability associated with KXRF bone lead measurement in young adults.
title_sort measurement variability associated with kxrf bone lead measurement in young adults.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1637955/
https://www.ncbi.nlm.nih.gov/pubmed/10706530
work_keys_str_mv AT hoppinja measurementvariabilityassociatedwithkxrfboneleadmeasurementinyoungadults
AT aroa measurementvariabilityassociatedwithkxrfboneleadmeasurementinyoungadults
AT huh measurementvariabilityassociatedwithkxrfboneleadmeasurementinyoungadults
AT ryanpb measurementvariabilityassociatedwithkxrfboneleadmeasurementinyoungadults