Cargando…

Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study

BACKGROUND: As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermom...

Descripción completa

Detalles Bibliográficos
Autor principal: Smith, Linda S
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC166172/
https://www.ncbi.nlm.nih.gov/pubmed/12807535
http://dx.doi.org/10.1186/1472-6955-2-1
_version_ 1782120858059276288
author Smith, Linda S
author_facet Smith, Linda S
author_sort Smith, Linda S
collection PubMed
description BACKGROUND: As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1) to examine age, race, site as variables affecting temperature measurement in adults, and 2) to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. METHODS: Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120) of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F) measured at oral, skin (simultaneous), immediately followed by rectal sites with four each mercury-glass (BD) and Galinstan-glass (Geratherm) thermometers; 10 minute dwell times. RESULTS: Participants averaged 61.6 years (SD 17.9), 188 pounds (SD 55.3); 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F): oral (0.142 – 0.265), axilla (0.167 – 0.339), groin (0.037 – 0.321), and rectal (-0.111 – 0.111). Race correlated with age, temperature readings each site and device. CONCLUSION: Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered the gold standard, mercury-glass thermometers may no longer be available worldwide. Therefore, mercury-free, environmentally safe low-tech Galinstan-in-glass may be an appropriate replacement. This is especially important as we face new, internationally transmitted diseases.
format Text
id pubmed-166172
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-1661722003-07-26 Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study Smith, Linda S BMC Nurs Research Article BACKGROUND: As a result of the recent international vigilance regarding disease assessment, accurate measurement of body temperature has become increasingly important. Yet, trusted low-tech, portable mercury glass thermometers are no longer available. Thus, comparing accuracy of mercury-free thermometers with mercury devices is essential. Study purposes were 1) to examine age, race, site as variables affecting temperature measurement in adults, and 2) to compare clinical accuracy of low-tech Galinstan-in-glass device to mercury-in-glass at oral, axillary, groin, and rectal sites in adults. METHODS: Setting 176 bed accredited healthcare facility, rural northwest US Participants Convenience sample (N = 120) of hospitalized persons ≥ 18 years old. Instruments Temperatures (°F) measured at oral, skin (simultaneous), immediately followed by rectal sites with four each mercury-glass (BD) and Galinstan-glass (Geratherm) thermometers; 10 minute dwell times. RESULTS: Participants averaged 61.6 years (SD 17.9), 188 pounds (SD 55.3); 61% female; race: 85% White, 8.3% Native Am., 4.2% Hispanic, 1.7 % Asian, 0.8% Black. For both mercury and Galinstan-glass thermometers, within-subject temperature readings were highest rectally; followed by oral, then skin sites. Galinstan assessments demonstrated rectal sites 0.91°F > oral and ≅ 1.3°F > skin sites. Devices strongly correlated between and across sites. Site difference scores between devices showed greatest variability at skin sites; least at rectal site. 95% confidence intervals of difference scores by site (°F): oral (0.142 – 0.265), axilla (0.167 – 0.339), groin (0.037 – 0.321), and rectal (-0.111 – 0.111). Race correlated with age, temperature readings each site and device. CONCLUSION: Temperature readings varied by age, race. Mercury readings correlated with Galinstan thermometer readings at all sites. Site mean differences between devices were considered clinically insignificant. Still considered the gold standard, mercury-glass thermometers may no longer be available worldwide. Therefore, mercury-free, environmentally safe low-tech Galinstan-in-glass may be an appropriate replacement. This is especially important as we face new, internationally transmitted diseases. BioMed Central 2003-06-15 /pmc/articles/PMC166172/ /pubmed/12807535 http://dx.doi.org/10.1186/1472-6955-2-1 Text en Copyright © 2003 Smith; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
Smith, Linda S
Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title_full Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title_fullStr Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title_full_unstemmed Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title_short Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – A comparison study
title_sort reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults – a comparison study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC166172/
https://www.ncbi.nlm.nih.gov/pubmed/12807535
http://dx.doi.org/10.1186/1472-6955-2-1
work_keys_str_mv AT smithlindas reexaminingageracesiteandthermometertypeasvariablesaffectingtemperaturemeasurementinadultsacomparisonstudy