Cargando…

Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours

The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different...

Descripción completa

Detalles Bibliográficos
Autores principales: Clevert, D.- A., Jung, E. M., Jungius, K.-P., Ertan, K., Kubale, R.
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1766021/
https://www.ncbi.nlm.nih.gov/pubmed/16823568
http://dx.doi.org/10.1007/s00330-006-0325-z
_version_ 1782131656191115264
author Clevert, D.- A.
Jung, E. M.
Jungius, K.-P.
Ertan, K.
Kubale, R.
author_facet Clevert, D.- A.
Jung, E. M.
Jungius, K.-P.
Ertan, K.
Kubale, R.
author_sort Clevert, D.- A.
collection PubMed
description The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different combinations of THI, SRI and SC. The effect on delineation, margin, tissue differentiation and posttumoral phenomena was evaluated with a three-point score. Additionally, 1oo not palpable tumours (diameters: 4–15 mm) were examined by contrast harmonic imaging (CHI) with power Doppler. After bolus injection (0.5 ml Optison), vascularisation and enhancement were observed for 20 min. The best combination for detection of margin, infiltration, echo pattern and posterior lesion boundary was the combination of SRI level 2 with SC low. THI was helpful for lesions OF more than 1 cm depth. In native Power Doppler, vessels were found in 54 of 100 lesions. Within 5 min after contrast medium (CM) injection, marginal and penetrating vessels increased in benign and malignant tumours and central vessels mostly in carcinomas (p<0.05). A diffuse CM accumulation was observed up to 20 min after injection in malignant tumours only (p<0.05). THI, SRI and SC improved delineation and tissue differentiation. Second-generation contrast agent allowed detection of tumour vascularisation with prolonged enhancement.
format Text
id pubmed-1766021
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-17660212007-01-10 Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours Clevert, D.- A. Jung, E. M. Jungius, K.-P. Ertan, K. Kubale, R. Eur Radiol Breast The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different combinations of THI, SRI and SC. The effect on delineation, margin, tissue differentiation and posttumoral phenomena was evaluated with a three-point score. Additionally, 1oo not palpable tumours (diameters: 4–15 mm) were examined by contrast harmonic imaging (CHI) with power Doppler. After bolus injection (0.5 ml Optison), vascularisation and enhancement were observed for 20 min. The best combination for detection of margin, infiltration, echo pattern and posterior lesion boundary was the combination of SRI level 2 with SC low. THI was helpful for lesions OF more than 1 cm depth. In native Power Doppler, vessels were found in 54 of 100 lesions. Within 5 min after contrast medium (CM) injection, marginal and penetrating vessels increased in benign and malignant tumours and central vessels mostly in carcinomas (p<0.05). A diffuse CM accumulation was observed up to 20 min after injection in malignant tumours only (p<0.05). THI, SRI and SC improved delineation and tissue differentiation. Second-generation contrast agent allowed detection of tumour vascularisation with prolonged enhancement. Springer-Verlag 2006-07-06 2007-01 /pmc/articles/PMC1766021/ /pubmed/16823568 http://dx.doi.org/10.1007/s00330-006-0325-z Text en © Springer-Verlag 2006
spellingShingle Breast
Clevert, D.- A.
Jung, E. M.
Jungius, K.-P.
Ertan, K.
Kubale, R.
Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title_full Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title_fullStr Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title_full_unstemmed Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title_short Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours
title_sort value of tissue harmonic imaging (thi) and contrast harmonic imaging (chi) in detection and characterisation of breast tumours
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1766021/
https://www.ncbi.nlm.nih.gov/pubmed/16823568
http://dx.doi.org/10.1007/s00330-006-0325-z
work_keys_str_mv AT clevertda valueoftissueharmonicimagingthiandcontrastharmonicimagingchiindetectionandcharacterisationofbreasttumours
AT jungem valueoftissueharmonicimagingthiandcontrastharmonicimagingchiindetectionandcharacterisationofbreasttumours
AT jungiuskp valueoftissueharmonicimagingthiandcontrastharmonicimagingchiindetectionandcharacterisationofbreasttumours
AT ertank valueoftissueharmonicimagingthiandcontrastharmonicimagingchiindetectionandcharacterisationofbreasttumours
AT kubaler valueoftissueharmonicimagingthiandcontrastharmonicimagingchiindetectionandcharacterisationofbreasttumours