Cargando…

Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study

BACKGROUND: Metastatic diseases and infections frequently involve the spine. This is the result of seeding of the vertebral body by tumor cells or bacteria delivered by venous blood from Batson's plexus, which is hypothesized to enter the vertebral body via the epidural veins. Isolated spinal s...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeh, Ming-Long, Heggeness, Michael H, Chen, Hsiang-Ho, Jassawalla, Jennifer, Luo, Zong-Ping
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1781419/
https://www.ncbi.nlm.nih.gov/pubmed/17192194
http://dx.doi.org/10.1186/1749-799X-1-18
_version_ 1782131873100595200
author Yeh, Ming-Long
Heggeness, Michael H
Chen, Hsiang-Ho
Jassawalla, Jennifer
Luo, Zong-Ping
author_facet Yeh, Ming-Long
Heggeness, Michael H
Chen, Hsiang-Ho
Jassawalla, Jennifer
Luo, Zong-Ping
author_sort Yeh, Ming-Long
collection PubMed
description BACKGROUND: Metastatic diseases and infections frequently involve the spine. This is the result of seeding of the vertebral body by tumor cells or bacteria delivered by venous blood from Batson's plexus, which is hypothesized to enter the vertebral body via the epidural veins. Isolated spinal segments deform significantly at the bony end plate when under compression. This deformation could cause a volume change of the vertebral body and may be accompanied by retrograde flow of venous blood. To date, this process has not been investigated quantitatively. The purpose of this study was to determine the volume changes of the vertebral body and basivertebral vein for a vertebral body under compression. METHODS: A three-dimensional finite element mesh model of the L4 segment with both adjacent discs was modified from a 3-D computed tomography scan image. An octagon representing the basivertebral vein was introduced into the center of the vertebral body in the model. Four compressive orientations (1500 N) were applied on the top disc. The volume change of the vertebral body model and the basivertebral vein were then computed. RESULTS: The volume change of the vertebral body was about 0.1 cm(3 )(16.3% of the basivertebral vein) for the four loading conditions. The maximum cross-sectional area reductions of the basivertebral vein and volume reduction were 1.54% and 1.02%, for uniform compression. CONCLUSION: Our study quantified the small but significant volume change of a modeled vertebral body and cross-sectional areas and that of the basivertebral vein, due to the inward bulging of the end plate under compression. This volume change could initiate the reverse flow of blood from the epidural venous system and cause seeding of tumors or bacterial cells.
format Text
id pubmed-1781419
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-17814192007-01-25 Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study Yeh, Ming-Long Heggeness, Michael H Chen, Hsiang-Ho Jassawalla, Jennifer Luo, Zong-Ping J Orthop Surg Research Article BACKGROUND: Metastatic diseases and infections frequently involve the spine. This is the result of seeding of the vertebral body by tumor cells or bacteria delivered by venous blood from Batson's plexus, which is hypothesized to enter the vertebral body via the epidural veins. Isolated spinal segments deform significantly at the bony end plate when under compression. This deformation could cause a volume change of the vertebral body and may be accompanied by retrograde flow of venous blood. To date, this process has not been investigated quantitatively. The purpose of this study was to determine the volume changes of the vertebral body and basivertebral vein for a vertebral body under compression. METHODS: A three-dimensional finite element mesh model of the L4 segment with both adjacent discs was modified from a 3-D computed tomography scan image. An octagon representing the basivertebral vein was introduced into the center of the vertebral body in the model. Four compressive orientations (1500 N) were applied on the top disc. The volume change of the vertebral body model and the basivertebral vein were then computed. RESULTS: The volume change of the vertebral body was about 0.1 cm(3 )(16.3% of the basivertebral vein) for the four loading conditions. The maximum cross-sectional area reductions of the basivertebral vein and volume reduction were 1.54% and 1.02%, for uniform compression. CONCLUSION: Our study quantified the small but significant volume change of a modeled vertebral body and cross-sectional areas and that of the basivertebral vein, due to the inward bulging of the end plate under compression. This volume change could initiate the reverse flow of blood from the epidural venous system and cause seeding of tumors or bacterial cells. BioMed Central 2006-12-27 /pmc/articles/PMC1781419/ /pubmed/17192194 http://dx.doi.org/10.1186/1749-799X-1-18 Text en Copyright © 2006 Yeh et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yeh, Ming-Long
Heggeness, Michael H
Chen, Hsiang-Ho
Jassawalla, Jennifer
Luo, Zong-Ping
Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title_full Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title_fullStr Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title_full_unstemmed Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title_short Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
title_sort compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1781419/
https://www.ncbi.nlm.nih.gov/pubmed/17192194
http://dx.doi.org/10.1186/1749-799X-1-18
work_keys_str_mv AT yehminglong compressiveloadingattheendplatedirectlyregulatesflowanddeformationofthebasivertebralveinananalyticalstudy
AT heggenessmichaelh compressiveloadingattheendplatedirectlyregulatesflowanddeformationofthebasivertebralveinananalyticalstudy
AT chenhsiangho compressiveloadingattheendplatedirectlyregulatesflowanddeformationofthebasivertebralveinananalyticalstudy
AT jassawallajennifer compressiveloadingattheendplatedirectlyregulatesflowanddeformationofthebasivertebralveinananalyticalstudy
AT luozongping compressiveloadingattheendplatedirectlyregulatesflowanddeformationofthebasivertebralveinananalyticalstudy