Cargando…

Analysis of IgE turnover in non-sensitized and sensitized rats.

BACKGROUND: Although the levels of immunoglobulin E (IgE) in the circulating blood are often elevated in patients with allergic diseases, such levels cannot always be considered as pathognomonic signs of allergy. The induction of allergic reactions in the tissue was inferred to be related to the amo...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanashiro, K, Tokeshi, Y, Nakasone, T, Sunagawa, M, Nakamura, M, Kosugi, T
Formato: Texto
Lenguaje:English
Publicado: 2001
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1781713/
https://www.ncbi.nlm.nih.gov/pubmed/11577998
_version_ 1782131949417005056
author Hanashiro, K
Tokeshi, Y
Nakasone, T
Sunagawa, M
Nakamura, M
Kosugi, T
author_facet Hanashiro, K
Tokeshi, Y
Nakasone, T
Sunagawa, M
Nakamura, M
Kosugi, T
author_sort Hanashiro, K
collection PubMed
description BACKGROUND: Although the levels of immunoglobulin E (IgE) in the circulating blood are often elevated in patients with allergic diseases, such levels cannot always be considered as pathognomonic signs of allergy. The induction of allergic reactions in the tissue was inferred to be related to the amount of IgE passing through the vascular wall. AIMS: We attempted to clarify which compartment, the intravascular or extravascular, plays an important role in the regulation of the turnover of rat IgE. METHODS: The level of DNP-specific rat IgE in the serum was estimated by IgE-capture enzyme-linked immunosorbent assay, and the turnover of IgE was analyzed from its pharmacokinetic parameters. RESULTS: The transfer rate constants from the central to tissue compartment (Kct) were larger than those from the tissue to central compartment (Ktc) irrespective of the sensitized state. The value of the distribution volume of the tissue compartment (Vt) was larger than that of the distribution volume of the central compartment (Vc) irrespective of the sensitized state. CONCLUSIONS: These Findings suggest that the short half-life of rat IgE in the circulation could be attributable to the distribution of IgE from the intravascular to the extravascular compartment.
format Text
id pubmed-1781713
institution National Center for Biotechnology Information
language English
publishDate 2001
record_format MEDLINE/PubMed
spelling pubmed-17817132007-01-25 Analysis of IgE turnover in non-sensitized and sensitized rats. Hanashiro, K Tokeshi, Y Nakasone, T Sunagawa, M Nakamura, M Kosugi, T Mediators Inflamm Research Article BACKGROUND: Although the levels of immunoglobulin E (IgE) in the circulating blood are often elevated in patients with allergic diseases, such levels cannot always be considered as pathognomonic signs of allergy. The induction of allergic reactions in the tissue was inferred to be related to the amount of IgE passing through the vascular wall. AIMS: We attempted to clarify which compartment, the intravascular or extravascular, plays an important role in the regulation of the turnover of rat IgE. METHODS: The level of DNP-specific rat IgE in the serum was estimated by IgE-capture enzyme-linked immunosorbent assay, and the turnover of IgE was analyzed from its pharmacokinetic parameters. RESULTS: The transfer rate constants from the central to tissue compartment (Kct) were larger than those from the tissue to central compartment (Ktc) irrespective of the sensitized state. The value of the distribution volume of the tissue compartment (Vt) was larger than that of the distribution volume of the central compartment (Vc) irrespective of the sensitized state. CONCLUSIONS: These Findings suggest that the short half-life of rat IgE in the circulation could be attributable to the distribution of IgE from the intravascular to the extravascular compartment. 2001-08 /pmc/articles/PMC1781713/ /pubmed/11577998 Text en
spellingShingle Research Article
Hanashiro, K
Tokeshi, Y
Nakasone, T
Sunagawa, M
Nakamura, M
Kosugi, T
Analysis of IgE turnover in non-sensitized and sensitized rats.
title Analysis of IgE turnover in non-sensitized and sensitized rats.
title_full Analysis of IgE turnover in non-sensitized and sensitized rats.
title_fullStr Analysis of IgE turnover in non-sensitized and sensitized rats.
title_full_unstemmed Analysis of IgE turnover in non-sensitized and sensitized rats.
title_short Analysis of IgE turnover in non-sensitized and sensitized rats.
title_sort analysis of ige turnover in non-sensitized and sensitized rats.
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1781713/
https://www.ncbi.nlm.nih.gov/pubmed/11577998
work_keys_str_mv AT hanashirok analysisofigeturnoverinnonsensitizedandsensitizedrats
AT tokeshiy analysisofigeturnoverinnonsensitizedandsensitizedrats
AT nakasonet analysisofigeturnoverinnonsensitizedandsensitizedrats
AT sunagawam analysisofigeturnoverinnonsensitizedandsensitizedrats
AT nakamuram analysisofigeturnoverinnonsensitizedandsensitizedrats
AT kosugit analysisofigeturnoverinnonsensitizedandsensitizedrats