Cargando…

Gait rehabilitation machines based on programmable footplates

BACKGROUND: Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the f...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmidt, Henning, Werner, Cordula, Bernhardt, Rolf, Hesse, Stefan, Krüger, Jörg
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1804273/
https://www.ncbi.nlm.nih.gov/pubmed/17291335
http://dx.doi.org/10.1186/1743-0003-4-2
_version_ 1782132447983435776
author Schmidt, Henning
Werner, Cordula
Bernhardt, Rolf
Hesse, Stefan
Krüger, Jörg
author_facet Schmidt, Henning
Werner, Cordula
Bernhardt, Rolf
Hesse, Stefan
Krüger, Jörg
author_sort Schmidt, Henning
collection PubMed
description BACKGROUND: Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the first mobilization out of the bed, the wheelchair-bound patient should have the possibility to practise complex gait cycles as soon as possible. Steps in this direction were treadmill training with partial body weight support and most recently gait machines enabling the repetitive training of even surface gait and even of stair climbing. RESULTS: With treadmill training harness-secured and partially relieved wheelchair-mobilised patients could practise up to 1000 steps per session for the first time. Controlled trials in stroke and SCI patients, however, failed to show a superior result when compared to walking exercise on the floor. Most likely explanation was the effort for the therapists, e.g. manually setting the paretic limbs during the swing phase resulting in a too little gait intensity. The next steps were gait machines, either consisting of a powered exoskeleton and a treadmill (Lokomat, AutoAmbulator) or an electromechanical solution with the harness secured patient placed on movable foot plates (Gait Trainer GT I). For the latter, a large multi-centre trial with 155 non-ambulatory stroke patients (DEGAS) revealed a superior gait ability and competence in basic activities of living in the experimental group. The HapticWalker continued the end effector concept of movable foot plates, now fully programmable and equipped with 6 DOF force sensors. This device for the first time enables training of arbitrary walking situations, hence not only the simulation of floor walking but also for example of stair climbing and perturbations. CONCLUSION: Locomotor therapy is a fascinating new tool in rehabilitation, which is in line with modern principles of motor relearning promoting a task-specific repetitive approach. Sophisticated technical developments and positive randomized controlled trials form the basis of a growing acceptance worldwide to the benefits or our patients.
format Text
id pubmed-1804273
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-18042732007-02-24 Gait rehabilitation machines based on programmable footplates Schmidt, Henning Werner, Cordula Bernhardt, Rolf Hesse, Stefan Krüger, Jörg J Neuroengineering Rehabil Methodology BACKGROUND: Gait restoration is an integral part of rehabilitation of brain lesioned patients. Modern concepts favour a task-specific repetitive approach, i.e. who wants to regain walking has to walk, while tone-inhibiting and gait preparatory manoeuvres had dominated therapy before. Following the first mobilization out of the bed, the wheelchair-bound patient should have the possibility to practise complex gait cycles as soon as possible. Steps in this direction were treadmill training with partial body weight support and most recently gait machines enabling the repetitive training of even surface gait and even of stair climbing. RESULTS: With treadmill training harness-secured and partially relieved wheelchair-mobilised patients could practise up to 1000 steps per session for the first time. Controlled trials in stroke and SCI patients, however, failed to show a superior result when compared to walking exercise on the floor. Most likely explanation was the effort for the therapists, e.g. manually setting the paretic limbs during the swing phase resulting in a too little gait intensity. The next steps were gait machines, either consisting of a powered exoskeleton and a treadmill (Lokomat, AutoAmbulator) or an electromechanical solution with the harness secured patient placed on movable foot plates (Gait Trainer GT I). For the latter, a large multi-centre trial with 155 non-ambulatory stroke patients (DEGAS) revealed a superior gait ability and competence in basic activities of living in the experimental group. The HapticWalker continued the end effector concept of movable foot plates, now fully programmable and equipped with 6 DOF force sensors. This device for the first time enables training of arbitrary walking situations, hence not only the simulation of floor walking but also for example of stair climbing and perturbations. CONCLUSION: Locomotor therapy is a fascinating new tool in rehabilitation, which is in line with modern principles of motor relearning promoting a task-specific repetitive approach. Sophisticated technical developments and positive randomized controlled trials form the basis of a growing acceptance worldwide to the benefits or our patients. BioMed Central 2007-02-09 /pmc/articles/PMC1804273/ /pubmed/17291335 http://dx.doi.org/10.1186/1743-0003-4-2 Text en Copyright © 2007 Schmidt et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Schmidt, Henning
Werner, Cordula
Bernhardt, Rolf
Hesse, Stefan
Krüger, Jörg
Gait rehabilitation machines based on programmable footplates
title Gait rehabilitation machines based on programmable footplates
title_full Gait rehabilitation machines based on programmable footplates
title_fullStr Gait rehabilitation machines based on programmable footplates
title_full_unstemmed Gait rehabilitation machines based on programmable footplates
title_short Gait rehabilitation machines based on programmable footplates
title_sort gait rehabilitation machines based on programmable footplates
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1804273/
https://www.ncbi.nlm.nih.gov/pubmed/17291335
http://dx.doi.org/10.1186/1743-0003-4-2
work_keys_str_mv AT schmidthenning gaitrehabilitationmachinesbasedonprogrammablefootplates
AT wernercordula gaitrehabilitationmachinesbasedonprogrammablefootplates
AT bernhardtrolf gaitrehabilitationmachinesbasedonprogrammablefootplates
AT hessestefan gaitrehabilitationmachinesbasedonprogrammablefootplates
AT krugerjorg gaitrehabilitationmachinesbasedonprogrammablefootplates