Cargando…

Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques

Accurate characterization of the physicochemical properties of aerosols generated for inhalation toxicology studies is essential for obtaining meaningful results. Great emphasis must also be placed on characterizing particle properties of materials as administered in inhalation studies. Thus, resear...

Descripción completa

Detalles Bibliográficos
Autores principales: Stefaniak, Aleksandr B, Hoover, Mark D, Dickerson, Robert M, Day, Gregory A, Breysse, Patrick N, Scripsick, Ronald C
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1810321/
https://www.ncbi.nlm.nih.gov/pubmed/17328812
http://dx.doi.org/10.1186/1743-8977-4-3
_version_ 1782132578111717376
author Stefaniak, Aleksandr B
Hoover, Mark D
Dickerson, Robert M
Day, Gregory A
Breysse, Patrick N
Scripsick, Ronald C
author_facet Stefaniak, Aleksandr B
Hoover, Mark D
Dickerson, Robert M
Day, Gregory A
Breysse, Patrick N
Scripsick, Ronald C
author_sort Stefaniak, Aleksandr B
collection PubMed
description Accurate characterization of the physicochemical properties of aerosols generated for inhalation toxicology studies is essential for obtaining meaningful results. Great emphasis must also be placed on characterizing particle properties of materials as administered in inhalation studies. Thus, research is needed to identify a suite of techniques capable of characterizing the multiple particle properties (i.e., size, mass, surface area, number) of a material that may influence toxicity. The purpose of this study was to characterize the morphology and investigate the size distribution of a model toxicant, beryllium. Beryllium metal, oxides, and alloy particles were aerodynamically size-separated using an aerosol cyclone, imaged dry using scanning electron microscopy (SEM), then characterized using phase contrast microscopy (PCM), a liquid suspension particle counter (LPC), and computer-controlled SEM (CCSEM). Beryllium metal powder was compact with smaller sub-micrometer size particles attached to the surface of larger particles, whereas the beryllium oxides and alloy particles were clusters of primary particles. As expected, the geometric mean (GM) diameter of metal powder determined using PCM decreased with aerodynamic size, but when suspended in liquid for LPC or CCSEM analysis, the GM diameter decreased by a factor of two (p < 0.001). This observation suggested that the smaller submicrometer size particles attached to the surface of larger particles and/or particle agglomerates detach in liquid, thereby shifting the particle size distribution downward. The GM diameters of the oxide materials were similar regardless of sizing technique, but observed differences were generally significant (p < 0.001). For oxides, aerodynamic cluster size will dictate deposition in the lung, but primary particle size may influence biological activity. The GM diameter of alloy particles determined using PCM became smaller with decreasing aerodynamic size fraction; however, when suspended in liquid for CCSEM and LPC analyses, GM particle size decreased by a factor of two (p < 0.001) suggesting that alloy particles detach in liquid. Detachment of particles in liquid could have significance for the expected versus actual size (and number) distribution of aerosol delivered to an exposure subject. Thus, a suite of complimentary analytical techniques may be necessary for estimating size distribution. Consideration should be given to thoroughly understanding the influence of any liquid vehicle which may alter the expected aerosol size distribution.
format Text
id pubmed-1810321
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-18103212007-03-06 Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques Stefaniak, Aleksandr B Hoover, Mark D Dickerson, Robert M Day, Gregory A Breysse, Patrick N Scripsick, Ronald C Part Fibre Toxicol Short Report Accurate characterization of the physicochemical properties of aerosols generated for inhalation toxicology studies is essential for obtaining meaningful results. Great emphasis must also be placed on characterizing particle properties of materials as administered in inhalation studies. Thus, research is needed to identify a suite of techniques capable of characterizing the multiple particle properties (i.e., size, mass, surface area, number) of a material that may influence toxicity. The purpose of this study was to characterize the morphology and investigate the size distribution of a model toxicant, beryllium. Beryllium metal, oxides, and alloy particles were aerodynamically size-separated using an aerosol cyclone, imaged dry using scanning electron microscopy (SEM), then characterized using phase contrast microscopy (PCM), a liquid suspension particle counter (LPC), and computer-controlled SEM (CCSEM). Beryllium metal powder was compact with smaller sub-micrometer size particles attached to the surface of larger particles, whereas the beryllium oxides and alloy particles were clusters of primary particles. As expected, the geometric mean (GM) diameter of metal powder determined using PCM decreased with aerodynamic size, but when suspended in liquid for LPC or CCSEM analysis, the GM diameter decreased by a factor of two (p < 0.001). This observation suggested that the smaller submicrometer size particles attached to the surface of larger particles and/or particle agglomerates detach in liquid, thereby shifting the particle size distribution downward. The GM diameters of the oxide materials were similar regardless of sizing technique, but observed differences were generally significant (p < 0.001). For oxides, aerodynamic cluster size will dictate deposition in the lung, but primary particle size may influence biological activity. The GM diameter of alloy particles determined using PCM became smaller with decreasing aerodynamic size fraction; however, when suspended in liquid for CCSEM and LPC analyses, GM particle size decreased by a factor of two (p < 0.001) suggesting that alloy particles detach in liquid. Detachment of particles in liquid could have significance for the expected versus actual size (and number) distribution of aerosol delivered to an exposure subject. Thus, a suite of complimentary analytical techniques may be necessary for estimating size distribution. Consideration should be given to thoroughly understanding the influence of any liquid vehicle which may alter the expected aerosol size distribution. BioMed Central 2007-02-28 /pmc/articles/PMC1810321/ /pubmed/17328812 http://dx.doi.org/10.1186/1743-8977-4-3 Text en Copyright © 2007 Stefaniak et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Report
Stefaniak, Aleksandr B
Hoover, Mark D
Dickerson, Robert M
Day, Gregory A
Breysse, Patrick N
Scripsick, Ronald C
Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title_full Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title_fullStr Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title_full_unstemmed Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title_short Differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
title_sort differences in estimates of size distribution of beryllium powder materials using phase contrast microscopy, scanning electron microscopy, and liquid suspension counter techniques
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1810321/
https://www.ncbi.nlm.nih.gov/pubmed/17328812
http://dx.doi.org/10.1186/1743-8977-4-3
work_keys_str_mv AT stefaniakaleksandrb differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques
AT hoovermarkd differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques
AT dickersonrobertm differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques
AT daygregorya differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques
AT breyssepatrickn differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques
AT scripsickronaldc differencesinestimatesofsizedistributionofberylliumpowdermaterialsusingphasecontrastmicroscopyscanningelectronmicroscopyandliquidsuspensioncountertechniques