Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to qu...

Descripción completa

Detalles Bibliográficos
Autores principales: Dauer, Lawrence T, Casciotta, Kevin A, Erdi, Yusuf E, Rothenberg, Lawrence N
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1831769/
https://www.ncbi.nlm.nih.gov/pubmed/17367529
http://dx.doi.org/10.1186/1471-2342-7-5
_version_ 1782132793982058496
author Dauer, Lawrence T
Casciotta, Kevin A
Erdi, Yusuf E
Rothenberg, Lawrence N
author_facet Dauer, Lawrence T
Casciotta, Kevin A
Erdi, Yusuf E
Rothenberg, Lawrence N
author_sort Dauer, Lawrence T
collection PubMed
description BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm(3 )ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.
format Text
id pubmed-1831769
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-18317692007-03-24 Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans Dauer, Lawrence T Casciotta, Kevin A Erdi, Yusuf E Rothenberg, Lawrence N BMC Med Imaging Research Article BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm(3 )ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans. BioMed Central 2007-03-16 /pmc/articles/PMC1831769/ /pubmed/17367529 http://dx.doi.org/10.1186/1471-2342-7-5 Text en Copyright © 2007 Dauer et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Dauer, Lawrence T
Casciotta, Kevin A
Erdi, Yusuf E
Rothenberg, Lawrence N
Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title_full Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title_fullStr Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title_full_unstemmed Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title_short Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans
title_sort radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical ct scans
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1831769/
https://www.ncbi.nlm.nih.gov/pubmed/17367529
http://dx.doi.org/10.1186/1471-2342-7-5
work_keys_str_mv AT dauerlawrencet radiationdosereductionatapricetheeffectivenessofamalegonadalshieldduringhelicalctscans
AT casciottakevina radiationdosereductionatapricetheeffectivenessofamalegonadalshieldduringhelicalctscans
AT erdiyusufe radiationdosereductionatapricetheeffectivenessofamalegonadalshieldduringhelicalctscans
AT rothenberglawrencen radiationdosereductionatapricetheeffectivenessofamalegonadalshieldduringhelicalctscans