Cargando…
Evaluation of Diagnostic Accuracy, Feasibility and Client Preference for Rapid Oral Fluid-Based Diagnosis of HIV Infection in Rural India
BACKGROUND: Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick® ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field e...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1838923/ https://www.ncbi.nlm.nih.gov/pubmed/17426815 http://dx.doi.org/10.1371/journal.pone.0000367 |
Sumario: | BACKGROUND: Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick® ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based OraQuick® Rapid HIV1/2 test in a rural hospital in India. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional, hospital-based study was conducted in 450 consenting participants with suspected HIV infection in rural India. The objectives were to evaluate performance, client preference and feasibility of the OraQuick® Rapid HIV-1/2 tests. Two Oraquick® Rapid HIV1/2 tests (oral fluid and finger stick) were administered in parallel with confirmatory ELISA/Western Blot (reference standard). Pre- and post-test counseling and face to face interviews were conducted to determine client preference. Of the 450 participants, 146 were deemed to be HIV sero-positive using the reference standard (seropositivity rate of 32% (95% confidence interval [CI] 28%, 37%)). The OraQuick test on oral fluid specimens had better performance with a sensitivity of 100% (95% CI 98, 100) and a specificity of 100% (95% CI 99, 100), as compared to the OraQuick test on finger stick specimens with a sensitivity of 100% (95% CI 98, 100), and a specificity of 99.7% (95% CI 98.4, 99.9). The OraQuick oral fluid-based test was preferred by 87% of the participants for first time testing and 60% of the participants for repeat testing. CONCLUSION/SIGNIFICANCE: In a rural Indian hospital setting, the OraQuick® Rapid- HIV1/2 test was found to be highly accurate. The oral fluid-based test performed marginally better than the finger stick test. The oral OraQuick test was highly preferred by participants. In the context of global efforts to scale-up HIV testing, our data suggest that oral fluid-based rapid HIV testing may work well in rural, resource-limited settings. |
---|