Cargando…

National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants

BACKGROUND: We aimed to: (i) assess compliance with a new smokefree law in a range of hospitality settings; and (ii) to assess the impact of the new law by measuring air quality and making comparisons with air quality in outdoor smoking areas and with international data from hospitality settings. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilson, Nick, Edwards, Richard, Maher, Anthony, Näthe, Jenny, Jalali, Rafed
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1890282/
https://www.ncbi.nlm.nih.gov/pubmed/17511877
http://dx.doi.org/10.1186/1471-2458-7-85
_version_ 1782133712420339712
author Wilson, Nick
Edwards, Richard
Maher, Anthony
Näthe, Jenny
Jalali, Rafed
author_facet Wilson, Nick
Edwards, Richard
Maher, Anthony
Näthe, Jenny
Jalali, Rafed
author_sort Wilson, Nick
collection PubMed
description BACKGROUND: We aimed to: (i) assess compliance with a new smokefree law in a range of hospitality settings; and (ii) to assess the impact of the new law by measuring air quality and making comparisons with air quality in outdoor smoking areas and with international data from hospitality settings. METHODS: We included 34 pubs, restaurants and bars, 10 transportation settings, nine other indoor settings, six outdoor smoking areas of bars and restaurants, and six other outdoor settings. These were selected using a mix of random, convenience and purposeful sampling. The number of lit cigarettes among occupants at defined time points in each venue was observed and a portable real-time aerosol monitor was used to measure fine particulate levels (PM(2.5)). RESULTS: No smoking was observed during the data collection periods among over 3785 people present in the indoor venues, nor in any of the transportation settings. The levels of fine particulates were relatively low inside the bars, pubs and restaurants in the urban and rural settings (mean 30-minute level = 16 μg/m(3 )for 34 venues; range of mean levels for each category: 13 μg/m(3 )to 22 μg/m(3)). The results for other smokefree indoor settings (shops, offices etc) and for smokefree transportation settings (eg, buses, trains, etc) were even lower. However, some "outdoor" smoking areas attached to bars/restaurants had high levels of fine particulates, especially those that were partly enclosed (eg, up to a 30-minute mean value of 182 μg/m(3 )and a peak of maximum value of 284 μg/m(3)). The latter are far above WHO guideline levels for 24-hour exposure (ie, 25μg/m(3)). CONCLUSION: There was very high compliance with the new national smokefree law and this was also reflected by the relatively good indoor air quality in hospitality settings (compared to the "outdoor" smoking areas and the comparable settings in countries that permit indoor smoking). Nevertheless, adopting enhanced regulations (as used in various US and Canadian jurisdictions) may be needed to address hazardous air quality in relatively enclosed "outdoor" smoking areas.
format Text
id pubmed-1890282
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-18902822007-06-08 National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants Wilson, Nick Edwards, Richard Maher, Anthony Näthe, Jenny Jalali, Rafed BMC Public Health Research Article BACKGROUND: We aimed to: (i) assess compliance with a new smokefree law in a range of hospitality settings; and (ii) to assess the impact of the new law by measuring air quality and making comparisons with air quality in outdoor smoking areas and with international data from hospitality settings. METHODS: We included 34 pubs, restaurants and bars, 10 transportation settings, nine other indoor settings, six outdoor smoking areas of bars and restaurants, and six other outdoor settings. These were selected using a mix of random, convenience and purposeful sampling. The number of lit cigarettes among occupants at defined time points in each venue was observed and a portable real-time aerosol monitor was used to measure fine particulate levels (PM(2.5)). RESULTS: No smoking was observed during the data collection periods among over 3785 people present in the indoor venues, nor in any of the transportation settings. The levels of fine particulates were relatively low inside the bars, pubs and restaurants in the urban and rural settings (mean 30-minute level = 16 μg/m(3 )for 34 venues; range of mean levels for each category: 13 μg/m(3 )to 22 μg/m(3)). The results for other smokefree indoor settings (shops, offices etc) and for smokefree transportation settings (eg, buses, trains, etc) were even lower. However, some "outdoor" smoking areas attached to bars/restaurants had high levels of fine particulates, especially those that were partly enclosed (eg, up to a 30-minute mean value of 182 μg/m(3 )and a peak of maximum value of 284 μg/m(3)). The latter are far above WHO guideline levels for 24-hour exposure (ie, 25μg/m(3)). CONCLUSION: There was very high compliance with the new national smokefree law and this was also reflected by the relatively good indoor air quality in hospitality settings (compared to the "outdoor" smoking areas and the comparable settings in countries that permit indoor smoking). Nevertheless, adopting enhanced regulations (as used in various US and Canadian jurisdictions) may be needed to address hazardous air quality in relatively enclosed "outdoor" smoking areas. BioMed Central 2007-05-18 /pmc/articles/PMC1890282/ /pubmed/17511877 http://dx.doi.org/10.1186/1471-2458-7-85 Text en Copyright © 2007 Wilson et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wilson, Nick
Edwards, Richard
Maher, Anthony
Näthe, Jenny
Jalali, Rafed
National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title_full National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title_fullStr National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title_full_unstemmed National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title_short National smokefree law in New Zealand improves air quality inside bars, pubs and restaurants
title_sort national smokefree law in new zealand improves air quality inside bars, pubs and restaurants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1890282/
https://www.ncbi.nlm.nih.gov/pubmed/17511877
http://dx.doi.org/10.1186/1471-2458-7-85
work_keys_str_mv AT wilsonnick nationalsmokefreelawinnewzealandimprovesairqualityinsidebarspubsandrestaurants
AT edwardsrichard nationalsmokefreelawinnewzealandimprovesairqualityinsidebarspubsandrestaurants
AT maheranthony nationalsmokefreelawinnewzealandimprovesairqualityinsidebarspubsandrestaurants
AT nathejenny nationalsmokefreelawinnewzealandimprovesairqualityinsidebarspubsandrestaurants
AT jalalirafed nationalsmokefreelawinnewzealandimprovesairqualityinsidebarspubsandrestaurants