Preterm labour detection by use of a biophysical marker: the uterine electrical activity

BACKGROUND: The electrical activity of the uterine muscle is representative of uterine contractility. Its characterization may be used to detect a potential risk of preterm delivery in women, even at an early gestational stage. METHODS: We have investigated the effect of the recording electrode posi...

Descripción completa

Detalles Bibliográficos
Autores principales: Marque, Catherine K, Terrien, Jérémy, Rihana, Sandy, Germain, Guy
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1892062/
https://www.ncbi.nlm.nih.gov/pubmed/17570165
http://dx.doi.org/10.1186/1471-2393-7-S1-S5
_version_ 1782133818267795456
author Marque, Catherine K
Terrien, Jérémy
Rihana, Sandy
Germain, Guy
author_facet Marque, Catherine K
Terrien, Jérémy
Rihana, Sandy
Germain, Guy
author_sort Marque, Catherine K
collection PubMed
description BACKGROUND: The electrical activity of the uterine muscle is representative of uterine contractility. Its characterization may be used to detect a potential risk of preterm delivery in women, even at an early gestational stage. METHODS: We have investigated the effect of the recording electrode position on the spectral content of the signal by using a mathematical model of the women's abdomen. We have then compared the simulated results to actual recordings. On signals with noise reduced with a dedicated algorithm, we have characterized the main frequency components of the signal spectrum in order to compute parameters indicative of different situations: preterm contractions resulting nonetheless in term delivery (i.e. normal contractions) and preterm contractions leading to preterm delivery (i.e. high-risk contractions). A diagnosis system permitted us to discriminate between these different categories of contractions. As the position of the placenta seems to affect the frequency content of electrical activity, we have also investigated in monkeys, with internal electrodes attached on the uterus, the effect of the placenta on the spectral content of the electrical signals. RESULTS: In women, the best electrode position was the median vertical axis of the abdomen. The discrimination between high risk and normal contractions showed that it was possible to detect a risk of preterm labour as early as at the 27th week of pregnancy (Misclassification Rate range: 11–19.5%). Placental influence on electrical signals was evidenced in animal recordings, with higher energy content in high frequency bands, for signals recorded away from the placenta when compared to signals recorded above the placental insertion. However, we noticed, from pregnancy to labour, a similar evolution of the frequency content of the signal towards high frequencies, whatever the relative position of electrodes and placenta. CONCLUSION: On human recordings, this study has proved that it is possible to detect, by non-invasive abdominal recordings, a risk of preterm birth as early as the 27th week of pregnancy. On animal signals, we have evidenced that the placenta exerts a local influence on the characteristics of the electrical activity of the uterus. However, these differences have a small influence on premature delivery risk diagnosis when using proper diagnosis tools.
format Text
id pubmed-1892062
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-18920622007-06-15 Preterm labour detection by use of a biophysical marker: the uterine electrical activity Marque, Catherine K Terrien, Jérémy Rihana, Sandy Germain, Guy BMC Pregnancy Childbirth Proceedings BACKGROUND: The electrical activity of the uterine muscle is representative of uterine contractility. Its characterization may be used to detect a potential risk of preterm delivery in women, even at an early gestational stage. METHODS: We have investigated the effect of the recording electrode position on the spectral content of the signal by using a mathematical model of the women's abdomen. We have then compared the simulated results to actual recordings. On signals with noise reduced with a dedicated algorithm, we have characterized the main frequency components of the signal spectrum in order to compute parameters indicative of different situations: preterm contractions resulting nonetheless in term delivery (i.e. normal contractions) and preterm contractions leading to preterm delivery (i.e. high-risk contractions). A diagnosis system permitted us to discriminate between these different categories of contractions. As the position of the placenta seems to affect the frequency content of electrical activity, we have also investigated in monkeys, with internal electrodes attached on the uterus, the effect of the placenta on the spectral content of the electrical signals. RESULTS: In women, the best electrode position was the median vertical axis of the abdomen. The discrimination between high risk and normal contractions showed that it was possible to detect a risk of preterm labour as early as at the 27th week of pregnancy (Misclassification Rate range: 11–19.5%). Placental influence on electrical signals was evidenced in animal recordings, with higher energy content in high frequency bands, for signals recorded away from the placenta when compared to signals recorded above the placental insertion. However, we noticed, from pregnancy to labour, a similar evolution of the frequency content of the signal towards high frequencies, whatever the relative position of electrodes and placenta. CONCLUSION: On human recordings, this study has proved that it is possible to detect, by non-invasive abdominal recordings, a risk of preterm birth as early as the 27th week of pregnancy. On animal signals, we have evidenced that the placenta exerts a local influence on the characteristics of the electrical activity of the uterus. However, these differences have a small influence on premature delivery risk diagnosis when using proper diagnosis tools. BioMed Central 2007-06-01 /pmc/articles/PMC1892062/ /pubmed/17570165 http://dx.doi.org/10.1186/1471-2393-7-S1-S5 Text en Copyright © 2007 Marque et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Proceedings
Marque, Catherine K
Terrien, Jérémy
Rihana, Sandy
Germain, Guy
Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title_full Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title_fullStr Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title_full_unstemmed Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title_short Preterm labour detection by use of a biophysical marker: the uterine electrical activity
title_sort preterm labour detection by use of a biophysical marker: the uterine electrical activity
topic Proceedings
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1892062/
https://www.ncbi.nlm.nih.gov/pubmed/17570165
http://dx.doi.org/10.1186/1471-2393-7-S1-S5
work_keys_str_mv AT marquecatherinek pretermlabourdetectionbyuseofabiophysicalmarkertheuterineelectricalactivity
AT terrienjeremy pretermlabourdetectionbyuseofabiophysicalmarkertheuterineelectricalactivity
AT rihanasandy pretermlabourdetectionbyuseofabiophysicalmarkertheuterineelectricalactivity
AT germainguy pretermlabourdetectionbyuseofabiophysicalmarkertheuterineelectricalactivity