Cargando…
Microtitre plate-based antibacterial assay incorporating resazurin as an indicator of cell growth, and its application in the in vitro antibacterial screening of phytochemicals
The resazurin assay utilising microtitre-plate, described by Drummond and Waigh in 2000, has been modified to achieve more accuracy in the determination of the minimum inhibitory concentration (MIC) values of natural products, including crude extracts, chromatographic fractions or purified compounds...
Autores principales: | Sarker, Satyajit D., Nahar, Lutfun, Kumarasamy, Yashodharan |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Academic Press
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1895922/ https://www.ncbi.nlm.nih.gov/pubmed/17560319 http://dx.doi.org/10.1016/j.ymeth.2007.01.006 |
Ejemplares similares
-
Resazurin microtitre plate assay and Sensititre® MycoTB for detection of Mycobacterium tuberculosis resistance in a high tuberculosis resistance setting
por: Jaglal, Prenika, et al.
Publicado: (2019) -
Comparative evaluation of the Nitrate Reductase Assay and the Resazurin Microtitre Assay for drug susceptibility testing of Mycobacterium tuberculosis against first line anti-tuberculosis drugs
por: Sanchotene, Karine O., et al.
Publicado: (2008) -
Evaluation of the modified colorimetric resazurin microtiter plate-based antibacterial assay for rapid and reliable tuberculosis drug susceptibility testing
por: Katawera, Victoria, et al.
Publicado: (2014) -
Creating tissue on chip constructs in microtitre plates for drug discovery
por: Macdonald, N. P., et al.
Publicado: (2018) -
Determination of antibacterial activity and minimum inhibitory concentration of larval extract of fly via resazurin-based turbidometric assay
por: Teh, Chien Huey, et al.
Publicado: (2017)