A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection

This work describes the development of a dedicated, fully automated sequential-injection analysis (SIA) apparatus suitable for simultaneous electrogenerated chemiluminescence (ECL) and amperometric detection. The instrument is composed of a peristaltic pump, a multiposition selection valve, a home-m...

Descripción completa

Detalles Bibliográficos
Autores principales: Economou, Anastasios, Nika, Maria
Formato: Texto
Lenguaje:English
Publicado: 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1903453/
https://www.ncbi.nlm.nih.gov/pubmed/17671622
http://dx.doi.org/10.1155/JAMMC/2006/67571
_version_ 1782133957757763584
author Economou, Anastasios
Nika, Maria
author_facet Economou, Anastasios
Nika, Maria
author_sort Economou, Anastasios
collection PubMed
description This work describes the development of a dedicated, fully automated sequential-injection analysis (SIA) apparatus suitable for simultaneous electrogenerated chemiluminescence (ECL) and amperometric detection. The instrument is composed of a peristaltic pump, a multiposition selection valve, a home-made potentiostat, a thin-layer electrochemical/optical flow-through cell, and a light detector. Control of the experimental sequence and simultaneous data acquisition of the light and the current intensities were performed in LabVIEW6.1. The CL reagents and the sample were first aspirated as distinct zones into the holding coil of the analyser and, then, delivered to the cell; during their travel, the individual zones mixed and the ECL reaction was initiated as soon as the mixed regents reached the cell. The utility of the analyser was demonstrated for the detection of oxalate and [Formula: see text] based on their ECL reactions with [Formula: see text] and luminol, respectively.
format Text
id pubmed-1903453
institution National Center for Biotechnology Information
language English
publishDate 2006
record_format MEDLINE/PubMed
spelling pubmed-19034532007-08-01 A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection Economou, Anastasios Nika, Maria J Autom Methods Manag Chem Research Article This work describes the development of a dedicated, fully automated sequential-injection analysis (SIA) apparatus suitable for simultaneous electrogenerated chemiluminescence (ECL) and amperometric detection. The instrument is composed of a peristaltic pump, a multiposition selection valve, a home-made potentiostat, a thin-layer electrochemical/optical flow-through cell, and a light detector. Control of the experimental sequence and simultaneous data acquisition of the light and the current intensities were performed in LabVIEW6.1. The CL reagents and the sample were first aspirated as distinct zones into the holding coil of the analyser and, then, delivered to the cell; during their travel, the individual zones mixed and the ECL reaction was initiated as soon as the mixed regents reached the cell. The utility of the analyser was demonstrated for the detection of oxalate and [Formula: see text] based on their ECL reactions with [Formula: see text] and luminol, respectively. 2006 /pmc/articles/PMC1903453/ /pubmed/17671622 http://dx.doi.org/10.1155/JAMMC/2006/67571 Text en Copyright © 2006 Anastasios Economou and Maria Nika. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Economou, Anastasios
Nika, Maria
A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title_full A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title_fullStr A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title_full_unstemmed A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title_short A Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
title_sort fully automated sequential-injection analyser for dual electrogenerated chemiluminescence/amperometric detection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1903453/
https://www.ncbi.nlm.nih.gov/pubmed/17671622
http://dx.doi.org/10.1155/JAMMC/2006/67571
work_keys_str_mv AT economouanastasios afullyautomatedsequentialinjectionanalyserfordualelectrogeneratedchemiluminescenceamperometricdetection
AT nikamaria afullyautomatedsequentialinjectionanalyserfordualelectrogeneratedchemiluminescenceamperometricdetection
AT economouanastasios fullyautomatedsequentialinjectionanalyserfordualelectrogeneratedchemiluminescenceamperometricdetection
AT nikamaria fullyautomatedsequentialinjectionanalyserfordualelectrogeneratedchemiluminescenceamperometricdetection